ODOumar Drame

Oumar Drame

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oumar Drame has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Cheikh Mbow

    Fluid Mechanics and Applications Laboratory, Department of Physics, Faculty of Science and Technology, Cheikh Anta Diop University (UCAD), Senegal

    3 shared publications
  • Adama Sarr

    2 shared publications
  • Awa Mar

    Higher School of Engineering Sciences and Techniques, Amadou Moktar MBOW University, Dakar 45927, Senegal

    2 shared publications
  • Samba Dia

    Fluid Mechanics and Applications Laboratory, Department of Physics, Faculty of Science and Technology, Cheikh Anta Diop University (UCAD), Senegal

    2 shared publications
  • Serigne Thiao

    Department of Physics, Assane Seck Universty, Ziguinchor, Senegal

    2 shared publications
  • Awa Mar

    Pole of Sciences and Technologies, Higher School of Engineering Sciences and Techniques, Amadou Moktar MBOW University of Dakar (UAM), Dakar, Senegal

    1 shared publication

Latest Publications

  • Open Access

    CFD Analysis of a Multi-Effect Solar Distillation System in Sub-Saharan African Climatic Conditions

    by Serigne Thiao, Saly Diatta, Oumar Drame, Awa Mar, Mamadou Sow

    Water scarcity is a global crisis in sub-Saharan Africa, particularly in Senegal, due to climate change and population growth. Faced with this challenge, seawater desalination has emerged as an essential solution. To provide a more suitable solution, a Computational Fluid Dynamics (CFD)-based numerical study of a triple-effect solar desalination system was conducted. The methodology adopted relies on a series of calculations of the mass and energy balances associated with each effect. An analysis of the dynamics of water vapor across the different effects was performed using Ansys Fluent software. The results obtained highlight the role of water vapor pressure and temperature in freshwater production. Computational Fluid Dynamics analysis shows a temperature profile of 52 °C in the first effect, dropping to 34.5 °C in the third effect.

  • CFD Modeling of Multiphase Flows in Coastal Zones: Impact of Rheology on spilled oil behaviors

    by Oumar Drame, Samba Dia, Kodjo Kpode, Cheikh Mbow

    Crude oil rheology critically controls dispersion mechanisms during coastal oil spills and must be explicitly incorporated into predictive numerical models. In this study, a three-phase CFD–VOF framework is coupled with a non-Newtonian Herschel–Bulkley formulation to investigate the dispersion of light crude oil under nearshore wave conditions. The hydrodynamic configuration reproduces realistic shallow-water waves, while oil behavior is resolved through shear-dependent viscosity.For Hibernia crude oil, simulations show a rapid decrease in apparent viscosity from approximately 4.0 kg·m⁻¹·s⁻¹ at release to about 0.3 kg·m⁻¹·s⁻¹ within 20 s, followed by stabilization between 0.18 and 0.22 kg·m⁻¹·s⁻¹ beyond 40 s. This shear-thinning response enhances oil mobility, leading to pronounced surface spreading and thinning. The oil volume fraction at the free surface decreases from about 0.26 at 5 s to below 0.08 at 20 s and drops under 0.004 after 120 s, while vertical profiles indicate progressive immersion with volume fractions reaching approximately 0.04 at depth around 40 s. These results demonstrate that dispersion is governed by the coupling between hydrodynamic shear and rheological response, emphasizing the necessity of non-Newtonian modeling for reliable oil spill prediction and response planning.

  • Open Access

    Experimental and Numerical CFD Analysis of a Solar Dryer with Integration of Basalt Thermal Bed for Heat Storage

    by Serigne Thiao, Omar Drame, Awa Mar, Lat Ndiaye, Issakha Youm

    Solar thermal energy is available in abundance in a country like Senegal where direct solar radiation is on average 1950kWh/m2 per year. Solar drying is the most popular method to preserve food in our country. However, it is limited by the intermittent nature of the sun. The objective of this paper is to overcome the intermittency of the sun by integrating a thermal bed into the solar dryer. The thermal bed is made of basalt and biochar for heat storage and humidity absorption respectively. An experimental study was done using papaya and moringa leaves. The results obtained show that the thermal bed stores heat at the temperature of 39°C at 10p.m. Papaya is dried in two days and moringa leaves are dried in one day. For papaya slices, water content is 15% and was reached at the second day of drying. Also, moringa dry leaves water content is 8%. This value begins to be reached from 3 p.m. in the afternoon. Thus, the thermal bed temperature, the air temperature between the drying racks and the drying chamber outlet air temperature are respectively an average of 48.67°C, 48°C and 47.22°C compared to 34.33°C of the ambient temperature, a difference of more than 4°C. The experimental study is supported by a Computational fluid dynamic (CFD) analysis.


  • Open Access

    Experimental and Numerical CFD Analysis of a Solar Dryer with Integration of Basalt-Biochar Thermal Bed for Heat Storage and Humidity Absorption

    by Serigne Thiao, Omar Drame, Awa Mar, Lat Grand Ndiaye, Issakha Youm

    Solar thermal energy is available in abundance in a country like Senegal where direct solar radiation is on average 1950 kWh/m2 per year. Solar drying is the most popular method to preserve food in our country. However, it is limited by the intermittent nature of the sun. The objective of this paper is to overcome the intermittency of the sun by integrating a thermal bed into the solar dryer. The thermal bed is made of basalt and biochar for heat storage and humidity absorption respectively. An experimental study was done using papaya and moringa leaves. The results obtained show that the thermal bed stores heat at the temperature of 39 °C at 10 p.m. Papaya is dried in two days and moringa leaves are dried in one day. For papaya slices, water content is 15% and was reached at the second day of drying. Also, moringa dry leaves water content is 8%. This value begins to be reached from 3 p.m. in the afternoon. Thus, the thermal bed temperature, the air temperature between the drying racks and the drying chamber outlet air temperature are respectively an average of 48.67°C, 48°C and 47.22° C compared to 34.33°C of the ambient temperature, a difference of more than 4°C. The experimental study is supported by a Computational fluid dynamic (CFD) analysis.

  • Open Access

    CFD Analysis of the Generic Isolated Gable Roof Stadium: Impact of Opening Direction and Roof Angle for Wind Drift in Badminton

    by Vignesh Subramani Mahalakshmi, Nallavan Govindarajan, Ramakrishnan Raju, Oumar Drame

    Badminton is highly influenced by wind drift due to indoor ventilation, which changes the trajectory of the shuttlecock from the actual. To understand the influence of wind drift over different stadium configuration is studied using Computational Fluid Dynamics (CFD). CFD is an essential tool to assess and understand the impact of wind in the building environment for ventilation comforts. Many studies on natural or cross ventilation on the generic model and stadium infrastructure focus only on the ventilation comfort but limitedly on the wind influence like wind drift in badminton. Therefore, this paper presents a detailed study through computational analysis of the isolated generic model with three gable roof slopes ratio and two opening directions. The simulation is performed in a 3D steady Reynolds-Averaged Navier–Stokes (RANS) approach with the SST k–ω model. Validation is carried out with grid sensitivity study by comparing study of a published work with wind tunnel experiment data on a flat roof model. The results show that the gable roof in the longitudinal direction with a 6:12 and 4:12 sloped ratio performed better than a flat roof with a 6% and 13% volume flow rate higher with almost no wind drift near the ground (h=0.02m). The 2:12 sloped gable roof has a higher volume flow rate in both longitudinal and lateral wind flow than the flat roof, with 26% and 37 % higher but a more drifty environment.

  • Open Access

    Soumbedjioune tunnel in dakar: a case study for CFD modeling of fire-smoke extraction in a sinusoidal floor tunnel

    by Oumar Drame, Zeinebou Yahya, Adama Sarr, Cheikh Mbow

    Despite numerous studies on fires, each simulation faces several limitations. Fire is a complex phenomenon, and some of its processes remain poorly understood. Furthermore, the progression of flames and smoke is influenced by turbulent flow phenomena. In this context, this article delves into the analysis of smoke flow behavior using numerical fluid dynamics simulations (CFD) with the assistance of ANSYS FLUENT. The primary focus lies in describing the longitudinal ventilation system, a critical element for fire management. The chosen study area is the Soumbédjioune tunnel located in Dakar, Senegal, characterized by a sinusoidal floor with an amplitude equivalent to one-third of the entrance height. The tunnel has dimensions of 300 m in length (L), 10.5 m in width (W), and 7.22 m in height (H). To simulate the source of heat and smoke, a 2-cubic meter fire was placed in the center of the tunnel, modeling the combustion of N2, H2O, and O2 gases at a high temperature of 926.85 °C. The simulations yielded a critical ventilation velocity of 5.8 m/s, a crucial piece of information for fire management in this specific context. Furthermore, this article extends its analysis by examining the evolution of temperature and velocity contours in both ventilated and non-ventilated conditions, providing a deeper understanding of the underlying mechanisms at play.


  • Open Access

    Numerical simulation of the natural, forced and mixed convection in a tunnel with a flat track of sinusoidal shape and a roof opening

    by Oumar Drame, Cheikh Mbow, Florin Bode, Samba Dia, Omar Ngor Thiam

    In this work, we studied the mixed convection of the airflow in a tunnel open at both ends. The tunnel has a sinusoidal trace and the horizontal ceiling is provided with an opening in the center. The tunnel floor is uniformly heated. Although of interest for many industrial applications, the configuration of this study has been studied very little from an academic point of view. Coupled equations of Naiver-Stokes and energy are solved numerically by the finite volume method with the Boussinesq hypothesis. We analyzed the effect of the parameters that characterize heat transfer, and the flow structure. Several situations have been considered by varying the Richardson number (1.3610-3≤Ri≤2.17.104) for a Prandtl number Pr = 0.71.