David Nilsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Nilsson has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Johan Trygg
Computational Life Science Cluster (CLiC), Department of Chemistry, Umeå University
2 shared publications - Anneli Peolsson
Linköping University
1 shared publication - Annika Höjer
Norrmejerier, Mejerivägen 2, Umeå SE-906 22, Sweden
1 shared publication - Gunnel Peterson
Department of Health Medicine and Caring Sciences, Unit of Physiotherapy, Linköping University, Linköping, Sweden
1 shared publication - Johan Trygg
Chemometrics Lab, Computational Life Science Cluster (CLiC), Umeå University, Umeå SE-901 87, Sweden; Sartorius Corporate Research, Sartorius, Sartorius Stedim Data Analytics, Umeå SE-903 33, Sweden
1 shared publication Karin Hallin Saedén
Norrmejerier, Mejerivägen 2, Umeå SE-906 22, Sweden
1 shared publication
Latest Publications
- Open Access
- 1 November 2023
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 106 (11) , 7407-7418
Near-infrared hyperspectral image analysis for monitoring the cheese-ripening process
Ripening is the most crucial process step in cheese manufacturing and constitutes multiple biochemical alterations that describe the final cheese quality and its perceived sensory attributes. The assessment of the cheese-ripening process is challenging and requires the effective analysis of a multitude of biochemical changes occurring during the process. This study monitored the biochemical and sensory attribute changes of paraffin wax-covered long-ripening hard cheeses (n = 79) during ripening by collecting samples at different stages of ripening. Near-infrared hyperspectral (NIR-HS) imaging, together with free amino acid, chemical composition, and sensory attributes, was studied to monitor the biochemical changes during the ripening process. Orthogonal projection-based multivariate calibration methods were used to characterize ripening-related and orthogonal components as well as the distribution map of chemical components. The results approve the NIR-HS imaging as a rapid tool for monitoring cheese maturity during ripening. Moreover, the pixelwise evaluation of images shows the homogeneity of cheese maturation at different stages of ripening. Among the chemical compositions, fat content and moisture are the most important variables correlating to NIR-HS images during the ripening process.
- 1 November 2023
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 106 (11) , 7407-7418
Open AccessNear-infrared hyperspectral image analysis for monitoring the cheese-ripening process
Ripening is the most crucial process step in cheese manufacturing and constitutes multiple biochemical alterations that describe the final cheese quality and its perceived sensory attributes. The assessment of the cheese-ripening process is challenging and requires the effective analysis of a multitude of biochemical changes occurring during the process. This study monitored the biochemical and sensory attribute changes of paraffin wax-covered long-ripening hard cheeses (n = 79) during ripening by collecting samples at different stages of ripening. Near-infrared hyperspectral (NIR-HS) imaging, together with free amino acid, chemical composition, and sensory attributes, was studied to monitor the biochemical changes during the ripening process. Orthogonal projection-based multivariate calibration methods were used to characterize ripening-related and orthogonal components as well as the distribution map of chemical components. The results approve the NIR-HS imaging as a rapid tool for monitoring cheese maturity during ripening. Moreover, the pixelwise evaluation of images shows the homogeneity of cheese maturation at different stages of ripening. Among the chemical compositions, fat content and moisture are the most important variables correlating to NIR-HS images during the ripening process.
- 13 February 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (5) , 3516-3524
Joint and Unique Multiblock Analysis for Integration and Calibration Transfer of NIR Instruments
In the present paper we introduce an end-to-end workflow named joint and unique multiblock analysis (JUMBA), which allows multiple sources of data to be analysed simultaneously to better understand how they complement each other. In near infrared (NIR) spectroscopy, calibration models between NIR spectra and responses are used to replace wet chemistry methods, where the models tend to be instrument-specific. Calibration transfer techniques are used for standardization of NIR-instrumentation, enabling the use of one model on several instruments. The current paper investigates both similarities and differences between a variety of NIR instruments using JUMBA. We demonstrate JUMBA on both a previously unpublished dataset where five NIR instruments measured mushroom substrate, and a publicly available dataset measured on corn samples. We found that NIR-spectra from different instrumentation largely shared the same underlying structures, an insight we took advantage of to perform calibration transfer. The proposed JUMBA transfer displayed excellent calibration transfer performance across the two analyzed datasets and outperformed existing methods in terms of both prediction accuracy and stability. When applied to a multi-instrument environment JUMBA transfer can integrate all instruments in the same model and will ensure a higher consistency between them compared to existing calibration transfer methods.
- 13 February 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (5) , 3516-3524
Joint and Unique Multiblock Analysis for Integration and Calibration Transfer of NIR Instruments
In the present paper we introduce an end-to-end workflow named joint and unique multiblock analysis (JUMBA), which allows multiple sources of data to be analysed simultaneously to better understand how they complement each other. In near infrared (NIR) spectroscopy, calibration models between NIR spectra and responses are used to replace wet chemistry methods, where the models tend to be instrument-specific. Calibration transfer techniques are used for standardization of NIR-instrumentation, enabling the use of one model on several instruments. The current paper investigates both similarities and differences between a variety of NIR instruments using JUMBA. We demonstrate JUMBA on both a previously unpublished dataset where five NIR instruments measured mushroom substrate, and a publicly available dataset measured on corn samples. We found that NIR-spectra from different instrumentation largely shared the same underlying structures, an insight we took advantage of to perform calibration transfer. The proposed JUMBA transfer displayed excellent calibration transfer performance across the two analyzed datasets and outperformed existing methods in terms of both prediction accuracy and stability. When applied to a multi-instrument environment JUMBA transfer can integrate all instruments in the same model and will ensure a higher consistency between them compared to existing calibration transfer methods.