Irina V. Popova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Irina V. Popova has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Alexey V. Cheban
Meshalkin National Medical Research Center Novosibirsk Russian Federation
7 shared publications - Andrey A. Karpenko
Meshalkin National Medical Research Center
7 shared publications - Artem A. Rabtsun
Meshalkin National Medical Research Center
6 shared publications - Alexander A. Gostev
Meshalkin National Medical Research Center
5 shared publications - Shoraan B. Saaya
Meshalkin National Medical Research Center
5 shared publications - Vladimir B. Starodubtsev
Meshalkin National Medical Research Center
4 shared publications
Latest Publications
- Open Access
Influence of Lamina Vastoadductoria Dissection on the Outcomes of Femoral Artery Extensive Lesion Stenting: A Pilot Randomised Investigation
Objective Aim of the study was to improve the immediate and long-term results of stenting of the superficial femoral artery in extended lesions with the changing of the biomechanics of SFA and of the first portion of the popliteal artery. Methods Pilot randomized prospective single-center study were included 70 patients. Patients were randomized into two groups in 1×1 format for 35 people using the envelope method. Self-expanding bare metal stents were used in all cases. At the first group standard revascularization procedures with SFA stenting were performed; in the second group, the superficial femoral artery stenting was supplemented with fasciotomy in the Hunter’s canal with the superficial femoral artery intersection. The total observation period was 2 years. During the observation period an assessment of the clinical symptoms of the lower extremities, measurement of the ankle-brachial index and ultrasound duplex scanning of the operated segment were performed. Results All procedures in both groups were successfully performed. Primary patency through 24 months was 28.5% (10 of 35) in group 1 and 60% (21 of 35) in group 2 (p=0,015). Conclusions Changing the biomechanical properties of the distal of the superficial femoral artery segment and of the first portion of the popliteal artery is safe and contributes to the primary patency improvement during the stenting of extended of the superficial femoral artery lesions compared to standard SFA stenting. Dissection of the lamina vastoadductoria with transection of the collateral branches of the knee joint network reduces frequent and severe damages of stents after the stenting of the superficial femoral artery extended lesion. According to the frequency of complications in the early and mid-term postoperative period, limb salvage, mortality and the secondary patency rates, the new method is comparable with standard of the superficial femoral artery stenting.
Open AccessInfluence of Lamina Vastoadductoria Dissection on the Outcomes of Femoral Artery Extensive Lesion Stenting: A Pilot Randomised Investigation
Objective Aim of the study was to improve the immediate and long-term results of stenting of the superficial femoral artery in extended lesions with the changing of the biomechanics of SFA and of the first portion of the popliteal artery. Methods Pilot randomized prospective single-center study were included 70 patients. Patients were randomized into two groups in 1×1 format for 35 people using the envelope method. Self-expanding bare metal stents were used in all cases. At the first group standard revascularization procedures with SFA stenting were performed; in the second group, the superficial femoral artery stenting was supplemented with fasciotomy in the Hunter’s canal with the superficial femoral artery intersection. The total observation period was 2 years. During the observation period an assessment of the clinical symptoms of the lower extremities, measurement of the ankle-brachial index and ultrasound duplex scanning of the operated segment were performed. Results All procedures in both groups were successfully performed. Primary patency through 24 months was 28.5% (10 of 35) in group 1 and 60% (21 of 35) in group 2 (p=0,015). Conclusions Changing the biomechanical properties of the distal of the superficial femoral artery segment and of the first portion of the popliteal artery is safe and contributes to the primary patency improvement during the stenting of extended of the superficial femoral artery lesions compared to standard SFA stenting. Dissection of the lamina vastoadductoria with transection of the collateral branches of the knee joint network reduces frequent and severe damages of stents after the stenting of the superficial femoral artery extended lesion. According to the frequency of complications in the early and mid-term postoperative period, limb salvage, mortality and the secondary patency rates, the new method is comparable with standard of the superficial femoral artery stenting.
- Open Access
- 6 April 2021
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 36 (1) , 30-37
Outcomes of using various designs of carotid stents
Исходы применения различных конструкций каротидных стентов
- 6 April 2021
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 36 (1) , 30-37
Open AccessOutcomes of using various designs of carotid stents
Исходы применения различных конструкций каротидных стентов
- Open Access
- 13 November 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (5) , 2381
Hemodynamic changes in different types of carotid endarterectomy in the short- and long-term postoperative periods in patients with carotid artery stenosis
Динамика гемодинамических параметров при различных видах каротидной эндартерэктомии в ближайшем и отдаленном послеоперационном периоде у пациентов со стенозирующим каротидным атеросклерозом
- 13 November 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (5) , 2381
Open AccessHemodynamic changes in different types of carotid endarterectomy in the short- and long-term postoperative periods in patients with carotid artery stenosis
Динамика гемодинамических параметров при различных видах каротидной эндартерэктомии в ближайшем и отдаленном послеоперационном периоде у пациентов со стенозирующим каротидным атеросклерозом
- Open Access
- 3 July 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (3) , 2362
Intermediate results of the prospective randomized study on the effect of lamina vastoadductoria dissection after superficial femoral artery stenting on the restenosis incidence in TASC-II type C and D lesions
Aim. To compare the effectiveness of superficial femoral artery (SFA) stenting with/without lamina vastoadductoria dissection.Material and methods. The study included are 70 patients with TASCII type C and D lesions. All patients were divided onto 2 groups: group 1 (n=35) — conventional SFA stenting, group 2 (n=35) — SFA stenting with lamina vastoadductoria dissection. The average lesion length in group 1 was 22,92±5,62 cm, in group 2 — 21,2±5,42 cm. The primary endpoint was the absence of binary restenosis and reocclusion. Secondary composite endpoint was procedural success, limb salvage, secondary patency of the operated segment, intraoperative complications. The groups were comparable in age, sex, risk factors and comorbidities.Results. The procedural success in both groups was 100%. Primary patency after 24 months was 28,5% in group 1 and 60% in group 2. During the 24-month follow-up period, we recorded 1 death in group 2 due to myocardial infarction. In group 1, 2 deaths due to myocardial infarction and pancreatic cancer metastasis were recorded. Limb salvage was 100% in both groups. There were no intraoperative complications in both groups.Conclusion. Lamina vastoadductoria dissection is safe and does not lead to limb functional limitations. Biomechanical changes in the distal SFA segment contribute to the improvement of primary patency after stenting of SFA long lesions. Preliminary results of the single-center pilot study demonstrate the safety and efficacy of SFA stenting with lamina vastoadductoria dissection, emphasizing the need for further larger studies to compare it with conventional stenting and to assess the effectiveness during the long-term follow-up.
- 3 July 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (3) , 2362
Open AccessIntermediate results of the prospective randomized study on the effect of lamina vastoadductoria dissection after superficial femoral artery stenting on the restenosis incidence in TASC-II type C and D lesions
Aim. To compare the effectiveness of superficial femoral artery (SFA) stenting with/without lamina vastoadductoria dissection.Material and methods. The study included are 70 patients with TASCII type C and D lesions. All patients were divided onto 2 groups: group 1 (n=35) — conventional SFA stenting, group 2 (n=35) — SFA stenting with lamina vastoadductoria dissection. The average lesion length in group 1 was 22,92±5,62 cm, in group 2 — 21,2±5,42 cm. The primary endpoint was the absence of binary restenosis and reocclusion. Secondary composite endpoint was procedural success, limb salvage, secondary patency of the operated segment, intraoperative complications. The groups were comparable in age, sex, risk factors and comorbidities.Results. The procedural success in both groups was 100%. Primary patency after 24 months was 28,5% in group 1 and 60% in group 2. During the 24-month follow-up period, we recorded 1 death in group 2 due to myocardial infarction. In group 1, 2 deaths due to myocardial infarction and pancreatic cancer metastasis were recorded. Limb salvage was 100% in both groups. There were no intraoperative complications in both groups.Conclusion. Lamina vastoadductoria dissection is safe and does not lead to limb functional limitations. Biomechanical changes in the distal SFA segment contribute to the improvement of primary patency after stenting of SFA long lesions. Preliminary results of the single-center pilot study demonstrate the safety and efficacy of SFA stenting with lamina vastoadductoria dissection, emphasizing the need for further larger studies to compare it with conventional stenting and to assess the effectiveness during the long-term follow-up.
- Open Access
- 21 April 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (2)
Modern approaches to femoropopliteal bypass surgery: achievements and future prospects
Современные подходы к реваскуляризации бедренно-подколенных поражений. Достижения и перспективы
- 21 April 2020
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 19 (2)
Open AccessModern approaches to femoropopliteal bypass surgery: achievements and future prospects
Современные подходы к реваскуляризации бедренно-подколенных поражений. Достижения и перспективы
- Open Access
- 22 December 2019
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 18 (6) , 113-115
Surgical treatment of a patient with a giant iliac artery type E aneurysm and a horseshoe kidney
Клинический случай успешного оперативного лечения пациента с гигантской аневризмой подвздошной артерии типа Е и подковообразной почкой.
- 22 December 2019
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 18 (6) , 113-115
Open AccessSurgical treatment of a patient with a giant iliac artery type E aneurysm and a horseshoe kidney
Клинический случай успешного оперативного лечения пациента с гигантской аневризмой подвздошной артерии типа Е и подковообразной почкой.
- 1 January 2019
- Published by Geotar-Media Publishing Group in Angiology and vascular surgery
- Vol. 25 (4) , 64-75
Stenting of the carotid artery with CGuard and Acculink stents: interim results of a randomized trial
The study was undertaken to evaluate safety and efficacy of carotid stents Acculink (open-cell carotid stent) and CGuard (closed-cell type stent) in treatment of patients presenting with atherosclerotic lesions of carotid arteries. The study enrolled a total of 50 patients diagnosed with haemodynamically significant stenosis of the carotid artery and divided into two groups of 25 patients each. Group One patients received Acculink stents and Group Two patients underwent implantation of CGuard stents. Ultrasonographic examination was performed in all patients before and after surgery, as well as at 6 and 12 months thereafter; magnetic resonance imaging of the brain was carried out before and after surgery (at 24-48 postoperative hours and on POD 30). The entire period of follow up included 5 examinations of each patient by a neurologist. The obtained findings were statistically analysed using the Statistica 12 software (StatSoft, USA). The level of deviation of the null hypothesis of the absence of differences between the groups was regarded as significant at p0.77. Of these, multiple foci in Group One were encountered significantly more often than in Group Two (p=0.02). The patients with the Acculink stent implanted were found to develop 2 (4%) episodes of acute cerebral circulation impairment: the first one occurring after 24 hours and the second one at 28 days after stenting, with no such complications observed in Group Two patients. Comparing the two stents (Acculink and CGuard) demonstrated no advantages with respect to safety and efficacy of either stent in endovascular treatment of patients with atherosclerotic lesions of brachiocephalic arteries.
- 1 January 2019
- Published by Geotar-Media Publishing Group in Angiology and vascular surgery
- Vol. 25 (4) , 64-75
Stenting of the carotid artery with CGuard and Acculink stents: interim results of a randomized trial
The study was undertaken to evaluate safety and efficacy of carotid stents Acculink (open-cell carotid stent) and CGuard (closed-cell type stent) in treatment of patients presenting with atherosclerotic lesions of carotid arteries. The study enrolled a total of 50 patients diagnosed with haemodynamically significant stenosis of the carotid artery and divided into two groups of 25 patients each. Group One patients received Acculink stents and Group Two patients underwent implantation of CGuard stents. Ultrasonographic examination was performed in all patients before and after surgery, as well as at 6 and 12 months thereafter; magnetic resonance imaging of the brain was carried out before and after surgery (at 24-48 postoperative hours and on POD 30). The entire period of follow up included 5 examinations of each patient by a neurologist. The obtained findings were statistically analysed using the Statistica 12 software (StatSoft, USA). The level of deviation of the null hypothesis of the absence of differences between the groups was regarded as significant at p0.77. Of these, multiple foci in Group One were encountered significantly more often than in Group Two (p=0.02). The patients with the Acculink stent implanted were found to develop 2 (4%) episodes of acute cerebral circulation impairment: the first one occurring after 24 hours and the second one at 28 days after stenting, with no such complications observed in Group Two patients. Comparing the two stents (Acculink and CGuard) demonstrated no advantages with respect to safety and efficacy of either stent in endovascular treatment of patients with atherosclerotic lesions of brachiocephalic arteries.
- Open Access
- 20 August 2018
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 17 (4) , 74-80
Modern endovascular methods in treatment of patients with the tibial arteries lesion: determinants and perspectives
Endovascular interventions have proved efficacy in the treatment of the shin arteries lesion management. Lots of published works witness on the significance and future perspective of the field. The article is focused on the analysis of studies for previous 5 years, on various treatment approaches, balloons and cytostatics coated stents usage. The ways for interventions relsults improvement are sketched on tibial arteries with drug eluting stents.
- 20 August 2018
- Published by Silicea - Poligraf, LLC in Cardiovascular Therapy and Prevention
- Vol. 17 (4) , 74-80
Open AccessModern endovascular methods in treatment of patients with the tibial arteries lesion: determinants and perspectives
Endovascular interventions have proved efficacy in the treatment of the shin arteries lesion management. Lots of published works witness on the significance and future perspective of the field. The article is focused on the analysis of studies for previous 5 years, on various treatment approaches, balloons and cytostatics coated stents usage. The ways for interventions relsults improvement are sketched on tibial arteries with drug eluting stents.
- 1 January 2015
- Vol. 21 (2) , 136-8, 140
[Study of patency of vascular grafts manufactured by means of electrospinning].
In vivo experiments were carried out to study functioning of vascular grafts manufactured by means of electrospinning from solutions of polycaprolactone (PCL) and hexafluoroisopropanol (HFIP), PCL with 10% gelatine and a low-permeability inner layer (LPIL) 10 μm thick and PCL with 10% gelatine and LPIL (10 μm) wherein as polymeric base instead of PCL copolymer of lactic and hydroxyacetic acids (polylactide-co-glycolide, PLGA) was used. The grafts were implanted into the infrarenal portion of the aorta to 45 rats, 15 rats for each type of the graft. Patency of artificial vessels was assessed by means of magnetic resonance tomography and diagnostic ultrasound Dopplerography at 2, 4 and 20 weeks (5 animals for each time point). The state of the graft and surrounding tissues was analysed by means of intraoperative assessment, survey microscopy and survey fluorescent microscopy. The obtained findings demonstrated that vascular grafts made by electrospinning technique with a low-permeability inner layer are less prone to formation of the neointima and stenosing as compared with grafts having no such layer.
- 1 January 2015
- Vol. 21 (2) , 136-8, 140
[Study of patency of vascular grafts manufactured by means of electrospinning].
In vivo experiments were carried out to study functioning of vascular grafts manufactured by means of electrospinning from solutions of polycaprolactone (PCL) and hexafluoroisopropanol (HFIP), PCL with 10% gelatine and a low-permeability inner layer (LPIL) 10 μm thick and PCL with 10% gelatine and LPIL (10 μm) wherein as polymeric base instead of PCL copolymer of lactic and hydroxyacetic acids (polylactide-co-glycolide, PLGA) was used. The grafts were implanted into the infrarenal portion of the aorta to 45 rats, 15 rats for each type of the graft. Patency of artificial vessels was assessed by means of magnetic resonance tomography and diagnostic ultrasound Dopplerography at 2, 4 and 20 weeks (5 animals for each time point). The state of the graft and surrounding tissues was analysed by means of intraoperative assessment, survey microscopy and survey fluorescent microscopy. The obtained findings demonstrated that vascular grafts made by electrospinning technique with a low-permeability inner layer are less prone to formation of the neointima and stenosing as compared with grafts having no such layer.
- 1 January 2015
- Vol. 21 (4) , 178-84
[Effect of extracellular matrix components on adhesion of bone marrow multipotent mesenchymal stromal cells to polytetrafluoroethylene].
Search for new bioengineering materials for creation of small-diameter vascular grafts is currently a priority task. One of the promising trends of creating tissue engineering constructions is coating the internal layer of implants made of polytetrafluoroethylene (PTFE) with autologous mesenchymal multipotent stromal cells. In the study we assessed the ability of separate components of the extracellular matrix such as fibronectin, type I collagen and type IV collagen to influence adhesion, proliferation and morphology of mesenchymal multipotent stromal cells being cultured on PTFE. Bone marrow multipotent stromal cells taken from second-passage Wistar rats in the amount of 106 per 1 cm2 were applied onto PTFE. We used the following variants of preliminary treatment of the material prior to seeding: fibronectin with type I collagen, fibronectin with type IV collagen, fibronectin with a mixture of type I and IV collagens, as well as a control group without coating. After six weeks of cell growth on PTFE patches the samples were subjected to fixation in 10% formalin followed by haematoxylin-eosin stain and morphometric assessment of adhered cells by calculation using the software AxioVision (Carl Zeiss), assessing the number of cells, area of the cellular monolayer, dimensions and ratios of the area of separate cells and the area of cellular nuclei. The maximal area of the monolayer from mesenchymal multipotent stromal cells on the PTFE surface was revealed while culturing with a mixture of fibronectin and type I and IV collagens. Cell colonization density while treatment of the synthetic material with mixtures of fibronectin with type I collagen, type IV collagen and type I and IV collagens demonstrated the results exceeding the parameters of the control specimen 5-, 2.5- and 7-fold, respectively. Hence, extracellular matrix components considerably increase enhance adhesion of cells to PTFE, as well as improve formation of a monolayer from mesenchymal multipotent stromal cells.
- 1 January 2015
- Vol. 21 (4) , 178-84
[Effect of extracellular matrix components on adhesion of bone marrow multipotent mesenchymal stromal cells to polytetrafluoroethylene].
Search for new bioengineering materials for creation of small-diameter vascular grafts is currently a priority task. One of the promising trends of creating tissue engineering constructions is coating the internal layer of implants made of polytetrafluoroethylene (PTFE) with autologous mesenchymal multipotent stromal cells. In the study we assessed the ability of separate components of the extracellular matrix such as fibronectin, type I collagen and type IV collagen to influence adhesion, proliferation and morphology of mesenchymal multipotent stromal cells being cultured on PTFE. Bone marrow multipotent stromal cells taken from second-passage Wistar rats in the amount of 106 per 1 cm2 were applied onto PTFE. We used the following variants of preliminary treatment of the material prior to seeding: fibronectin with type I collagen, fibronectin with type IV collagen, fibronectin with a mixture of type I and IV collagens, as well as a control group without coating. After six weeks of cell growth on PTFE patches the samples were subjected to fixation in 10% formalin followed by haematoxylin-eosin stain and morphometric assessment of adhered cells by calculation using the software AxioVision (Carl Zeiss), assessing the number of cells, area of the cellular monolayer, dimensions and ratios of the area of separate cells and the area of cellular nuclei. The maximal area of the monolayer from mesenchymal multipotent stromal cells on the PTFE surface was revealed while culturing with a mixture of fibronectin and type I and IV collagens. Cell colonization density while treatment of the synthetic material with mixtures of fibronectin with type I collagen, type IV collagen and type I and IV collagens demonstrated the results exceeding the parameters of the control specimen 5-, 2.5- and 7-fold, respectively. Hence, extracellular matrix components considerably increase enhance adhesion of cells to PTFE, as well as improve formation of a monolayer from mesenchymal multipotent stromal cells.