Hailou Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hailou Wang has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Wei Zhang
National and Local Joint Engineering Research Center of Technical Fiber Composites for Safety and Health, School of Textile and Clothing Nantong University Nantong China
10 shared publicationsFayun Wei
7 shared publicationsBohong Gu
College of Textiles, Key Laboratory of High Performance Fibers & Products, Ministry of Education, Center of Civil Aviation Composite, Donghua University, China
5 shared publications- Jiamu Dai
School of Textile and Clothing, Nantong University, Nantong 226019, China
5 shared publications Baozhong Sun
4 shared publicationsCheng Zhang
4 shared publications
Latest Publications
- 2 October 2026
- Published by Wiley in Polymer Composites
Trade‐Off Between Internal and External Pressure Performance in 3D Angle‐Interlock Tubular Woven Composites
Internal pressure and localized external loads place competing demands on the structural design of tubular composites. Three‐dimensional angle‐interlock tubular woven composites (3DATWCs) with different warp lining yarn ratios and warp column counts were fabricated from carbon fiber and epoxy resin and evaluated through quasi‐static internal pressure, low‐cycle internal pressure fatigue, lateral compression, and low‐energy multiple and high‐energy single drop‐weight impact tests. A mechanical testing device was used to apply internal pressure within the small‐deformation regime. The results demonstrate that reducing the warp column count from 56 to 42 increased the weft density by 36.4% while also reducing wall thickness. At a warp lining yarn ratio of 5:1, the ultimate stress under internal pressure increased from 74.06 to 128.77 MPa, representing a 73.9% increase. Within the 56‐column series, increasing this ratio from 0:1 to 5:1 increased the fatigue life from 25 to 1645 cycles at 80% of the respective maximum internal pressure in quasi‐static tests. However, peak‐load retention after the third impact was 77.2% for ATWC‐1a and 54.6% for ATWC‐5a, despite nearly identical peak loads during the first impact. Under high‐energy single impact, ATWC‐3a reached an ultimate load of 3.79 kN, 17.3% above ATWC‐0a. These findings demonstrate that selecting an appropriate combination of warp column count and warp lining yarn ratio can balance internal pressure resistance and external load‐bearing capacity, guiding the structural design of lightweight woven composite tubes with different requirements for pressure resistance, fatigue life, and repeated‐impact tolerance.
- 2 October 2026
- Published by Wiley in Polymer Composites
Trade‐Off Between Internal and External Pressure Performance in 3D Angle‐Interlock Tubular Woven Composites
Internal pressure and localized external loads place competing demands on the structural design of tubular composites. Three‐dimensional angle‐interlock tubular woven composites (3DATWCs) with different warp lining yarn ratios and warp column counts were fabricated from carbon fiber and epoxy resin and evaluated through quasi‐static internal pressure, low‐cycle internal pressure fatigue, lateral compression, and low‐energy multiple and high‐energy single drop‐weight impact tests. A mechanical testing device was used to apply internal pressure within the small‐deformation regime. The results demonstrate that reducing the warp column count from 56 to 42 increased the weft density by 36.4% while also reducing wall thickness. At a warp lining yarn ratio of 5:1, the ultimate stress under internal pressure increased from 74.06 to 128.77 MPa, representing a 73.9% increase. Within the 56‐column series, increasing this ratio from 0:1 to 5:1 increased the fatigue life from 25 to 1645 cycles at 80% of the respective maximum internal pressure in quasi‐static tests. However, peak‐load retention after the third impact was 77.2% for ATWC‐1a and 54.6% for ATWC‐5a, despite nearly identical peak loads during the first impact. Under high‐energy single impact, ATWC‐3a reached an ultimate load of 3.79 kN, 17.3% above ATWC‐0a. These findings demonstrate that selecting an appropriate combination of warp column count and warp lining yarn ratio can balance internal pressure resistance and external load‐bearing capacity, guiding the structural design of lightweight woven composite tubes with different requirements for pressure resistance, fatigue life, and repeated‐impact tolerance.
- Open Access
Dual−Network PVA/PAM Hydrogel Strain Sensor for Machine−Learning−Assisted Rehabilitation−Oriented Hand Motion Monitoring
Wearable rehabilitation monitoring requires soft strain sensors with mechanical robustness, stable electromechanical responses, and intelligent motion recognition capability. Here, we report a poly(vinyl alcohol)/polyacrylamide (PVA/PAM) double−network hydrogel strain sensor for rehabilitation−oriented wearable monitoring. The hydrogel was prepared by ultraviolet ray (UV)−initiated acrylamide polymerization followed by freeze−thaw−induced PVA crystallization, forming a covalent PAM network interpenetrated with a physically crosslinked PVA network. The resulting hydrogel possessed a compact porous structure, improved stretchability, and stable deformation recovery. The optimized sensor exhibited a tensile strength of approximately 0.52 MPa, an elongation at break of approximately 480%, a response time of 0.12 s, and a recovery time of 0.17 s. It generated repeatable resistance signals under cyclic strain, finger bending, wrist motion, and grip training. Furthermore, the sensor enabled morse−code information transmission and support vector machine (SVM)−based recognition of rehabilitation−related hand states, including straight, bend, and clench. This work provides a soft hydrogel sensing platform for real−time rehabilitation−oriented hand motion, while morse−code encoding provides auxiliary assistance and an emergency communication function.
Open AccessDual−Network PVA/PAM Hydrogel Strain Sensor for Machine−Learning−Assisted Rehabilitation−Oriented Hand Motion Monitoring
Wearable rehabilitation monitoring requires soft strain sensors with mechanical robustness, stable electromechanical responses, and intelligent motion recognition capability. Here, we report a poly(vinyl alcohol)/polyacrylamide (PVA/PAM) double−network hydrogel strain sensor for rehabilitation−oriented wearable monitoring. The hydrogel was prepared by ultraviolet ray (UV)−initiated acrylamide polymerization followed by freeze−thaw−induced PVA crystallization, forming a covalent PAM network interpenetrated with a physically crosslinked PVA network. The resulting hydrogel possessed a compact porous structure, improved stretchability, and stable deformation recovery. The optimized sensor exhibited a tensile strength of approximately 0.52 MPa, an elongation at break of approximately 480%, a response time of 0.12 s, and a recovery time of 0.17 s. It generated repeatable resistance signals under cyclic strain, finger bending, wrist motion, and grip training. Furthermore, the sensor enabled morse−code information transmission and support vector machine (SVM)−based recognition of rehabilitation−related hand states, including straight, bend, and clench. This work provides a soft hydrogel sensing platform for real−time rehabilitation−oriented hand motion, while morse−code encoding provides auxiliary assistance and an emergency communication function.
- Open Access
- 7 August 2026
- Published by Elsevier in SSRN Electronic Journal
Dual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, wireless, and intelligent vascular system capable of self-powered sensing, with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- 7 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, wireless, and intelligent vascular system capable of self-powered sensing, with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- Open Access
- 9 May 2026
- Published by Elsevier in SSRN Electronic Journal
Dual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, self-powered, wireless, and intelligent vascular system with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- 9 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, self-powered, wireless, and intelligent vascular system with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- Open Access
- 7 April 2026
- Published by Elsevier in SSRN Electronic Journal
Dual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, self-powered, wireless, and intelligent vascular system with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- 7 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDual-electrode tube TENG for self-powered artificial blood vessels toward overall human health monitoring
Vascular grafting is an important therapy for cardiovascular diseases (CVDs), yet postoperative complications and the lack of continuous in situ monitoring still limit long-term outcomes. Flexible self-powered bioelectronics have recently enabled intelligent vascular grafts, but existing systems still rely on external power, lack signal continuity, and provide no intelligent analysis. Here, we report an integrated self-powered artificial blood vessel (SPABV) that harvests pulsatile blood-flow energy through a dual-electrode tubular architecture with a PTFE solid–liquid triboelectric interface. The compact SPABV (diameter 6 mm, length 27 cm) generates stable alternating signals under physiological pulsation with a peak voltage of 11.2 V and current of 278 nA, enabling rapid thrombus detection with a response time of 180 ms. A wireless Bluetooth module further allows real-time vascular and blood-status monitoring on mobile terminals. By extracting features from pulsatile electrical signals, an AI-assisted diagnostic model (1D-ResNet-T) achieves 100% prediction accuracy across multiple vascular and blood-condition categories. This work demonstrates a miniaturized, self-powered, wireless, and intelligent vascular system with significant potential for long-term vascular health management and next-generation implantable medical technologies.
- 22 February 2026
- Published by Wiley in Polymer Composites
- Vol. 47 (11) , 10571-10585
The Structural Optimization of Tubular Braided Composites for Axial Compressive Strength and Yarn Utilization Efficiency
In this study, structural optimization through axial yarn replacement and layered braiding was conducted to enhance yarn utilization efficiency and axial compressive strength. In the axial yarn replacement configuration, the primary function of the braiding yarns shifted from load‐bearing to providing constraint. The layered braiding method effectively mitigated the undulation of axial yarns. Additionally, finite element analysis results revealed that exchanging specific braiding yarns in the layered braiding process could enhance the constraint on axial yarns, although it led to premature interfacial and axial yarn failure. Significantly, compressive strength and yarn utilization efficiency were not necessarily positively correlated with the proportion of axial yarn unless the constraint provided by the braiding yarns is sufficient. Compared to the conventional composite, the compressive strength and yarn utilization efficiency of the optimized composite increased by an average of 152.86% and 114.96%, respectively. Noteworthily, the axial yarn replacement can markedly decrease the proportion of braiding yarn and the number of required carriers during braiding, thereby lowering the complexity of the coordinated movement of numerous carriers in a confined space of braiding equipment. This is of great significance for promoting its industrial application.
- 22 February 2026
- Published by Wiley in Polymer Composites
- Vol. 47 (11) , 10571-10585
The Structural Optimization of Tubular Braided Composites for Axial Compressive Strength and Yarn Utilization Efficiency
In this study, structural optimization through axial yarn replacement and layered braiding was conducted to enhance yarn utilization efficiency and axial compressive strength. In the axial yarn replacement configuration, the primary function of the braiding yarns shifted from load‐bearing to providing constraint. The layered braiding method effectively mitigated the undulation of axial yarns. Additionally, finite element analysis results revealed that exchanging specific braiding yarns in the layered braiding process could enhance the constraint on axial yarns, although it led to premature interfacial and axial yarn failure. Significantly, compressive strength and yarn utilization efficiency were not necessarily positively correlated with the proportion of axial yarn unless the constraint provided by the braiding yarns is sufficient. Compared to the conventional composite, the compressive strength and yarn utilization efficiency of the optimized composite increased by an average of 152.86% and 114.96%, respectively. Noteworthily, the axial yarn replacement can markedly decrease the proportion of braiding yarn and the number of required carriers during braiding, thereby lowering the complexity of the coordinated movement of numerous carriers in a confined space of braiding equipment. This is of great significance for promoting its industrial application.
- Open Access
- 10 February 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 41, 4446-4457
Structural effects on the radial mechanical performance of 3D tubular braided composite
- 10 February 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 41, 4446-4457
Open AccessStructural effects on the radial mechanical performance of 3D tubular braided composite
- 20 January 2026
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 14 (2)
Needled Kapok/Luffa composites with enhanced oil absorption and mechanical integrity for sustainable oil spill cleanup
- 20 January 2026
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 14 (2)
Needled Kapok/Luffa composites with enhanced oil absorption and mechanical integrity for sustainable oil spill cleanup
- 24 June 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (24) , 41379-41388
Synthesis of 0D-2D Ni(HCO3)2@NiFe2O4/LLG composites with abundant heterogeneous interface as electromagnetic wave absorber
- 24 June 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (24) , 41379-41388
Synthesis of 0D-2D Ni(HCO3)2@NiFe2O4/LLG composites with abundant heterogeneous interface as electromagnetic wave absorber