Arash Pourghorban
Arash Pourghorban has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jin Zhou
Department of Civil and Environmental Engineering, Monash University, Clayton, Australia
4 shared publications Behrouz Mohammad Kari
Building and Housing Research Center, Iran
2 shared publicationsHedyeh Asoodeh
Monash Univ
2 shared publicationsVictor W-C Chang
2 shared publications- Hua-Yan Deng1 shared publication
Victor Wc Chang
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Thermal Comfort Classification Using Electroencephalogram Spectral and Microstate Features
This study presents an electroencephalogram (EEG)‐based framework for thermal comfort classification by examining epoch sensitivity, feature importance, and interpretability, and the integration of spectral and microstate descriptors. Ninety sessions were conducted in a climate‐controlled chamber under neutral, warm, and cool conditions. Channel‐wise relative‐power (RP) features across five frequency bands were extracted using multiple epoch lengths (2‐, 4‐, 8‐, 16‐, and 32‐s) and evaluated using three classifiers: linear Support Vector Machine (SVM), radial‐basis‐function (RBF) SVM, and Random Forest (RF). Among the tested configurations, SVM‐RBF using 16‐s epochs achieved the highest overall performance when the full‐feature set was used. When reducing feature dimensionality, RF‐based analysis identified a compact top‐15 feature subset that achieved 76.67% accuracy, comparable with full feature set. Feature importance and stability validation consistently indicated that several frontal‐temporal RP features, particularly gamma_T5, theta_T4, gamma_T4, and beta_FP1, were the most reliable contributors to thermal discrimination. Supporting this observation, interpretability analysis showed that theta_T4 was most informative for identifying neutral from warm states, whereas gamma_FP1 activity provided stronger contrast under cool conditions. Finally, combining the selected top‐15 RP features with EEG microstate temporal descriptors further improved RF accuracy to 88.57%, surpassing the SVM‐RBF baseline. Collectively, these findings demonstrate the feasibility of EEG‐based thermal comfort modelling under within‐subject settings and highlight the value of integrating spectral with microstate features, while further validation using larger populations is needed to improve cross‐subject generalizability.
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Open AccessThermal Comfort Classification Using Electroencephalogram Spectral and Microstate Features
This study presents an electroencephalogram (EEG)‐based framework for thermal comfort classification by examining epoch sensitivity, feature importance, and interpretability, and the integration of spectral and microstate descriptors. Ninety sessions were conducted in a climate‐controlled chamber under neutral, warm, and cool conditions. Channel‐wise relative‐power (RP) features across five frequency bands were extracted using multiple epoch lengths (2‐, 4‐, 8‐, 16‐, and 32‐s) and evaluated using three classifiers: linear Support Vector Machine (SVM), radial‐basis‐function (RBF) SVM, and Random Forest (RF). Among the tested configurations, SVM‐RBF using 16‐s epochs achieved the highest overall performance when the full‐feature set was used. When reducing feature dimensionality, RF‐based analysis identified a compact top‐15 feature subset that achieved 76.67% accuracy, comparable with full feature set. Feature importance and stability validation consistently indicated that several frontal‐temporal RP features, particularly gamma_T5, theta_T4, gamma_T4, and beta_FP1, were the most reliable contributors to thermal discrimination. Supporting this observation, interpretability analysis showed that theta_T4 was most informative for identifying neutral from warm states, whereas gamma_FP1 activity provided stronger contrast under cool conditions. Finally, combining the selected top‐15 RP features with EEG microstate temporal descriptors further improved RF accuracy to 88.57%, surpassing the SVM‐RBF baseline. Collectively, these findings demonstrate the feasibility of EEG‐based thermal comfort modelling under within‐subject settings and highlight the value of integrating spectral with microstate features, while further validation using larger populations is needed to improve cross‐subject generalizability.
- Open Access
- 30 April 2025
- Published by Elsevier in Building and Environment
- Vol. 280
Electroencephalograph (EEG) Insights into Short-Term Thermal Adaptation and Alliesthesia: From Rapid Change to Steady State
- 30 April 2025
- Published by Elsevier in Building and Environment
- Vol. 280
Open AccessElectroencephalograph (EEG) Insights into Short-Term Thermal Adaptation and Alliesthesia: From Rapid Change to Steady State
- Open Access
- 22 March 2025
- Published by Elsevier in Measurement
- Vol. 252
Deciphering neural signatures of thermal perception: A fine-grained Electroencephalogram (EEG) analysis approach
- 22 March 2025
- Published by Elsevier in Measurement
- Vol. 252
Open AccessDeciphering neural signatures of thermal perception: A fine-grained Electroencephalogram (EEG) analysis approach
- Open Access
- 16 April 2024
- Published by Elsevier in Building and Environment
- Vol. 257
Delving beneath the surface: A systematic review of human experience of indoor thermal environments through electroencephalogram (EEG)
- 16 April 2024
- Published by Elsevier in Building and Environment
- Vol. 257
Open AccessDelving beneath the surface: A systematic review of human experience of indoor thermal environments through electroencephalogram (EEG)
- 2 September 2022
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 16 (1) , 57-71
Data-driven numerical models for the prediction of the thermal resistance value of the Enclosed Airspaces (EAs) in building envelopes
Enclosed airspaces (EAs) are a common component of different energy efficient technologies in building envelopes which have intrinsic adaptive behavior under various climatic conditions. The need for comprehensive accurate numerical models without restrictions for different applications still exists. Thus, for the first time, machine learning and regression-based techniques (Ordinary least squares Linear Regression (OLR), Support Vector Regression (SVR), Kernel Ridge Regression (KRR), k-Nearest Neighbors (kNN), r-Nearest Neighbors (rNN), and Artificial Neural Network (ANN)) were applied to develop precise models derived from the most credible experimental data with stochastic logic of testing and training in several runs. It was found that application of KRR, SVR, and ANN leads to the most desirable outcomes with highest R2 (0.97–0.99), and lowest errors, however OLR does not provide satisfactory results (R2 <0.6). Moreover, major deviations are observed for calculations by OLR, kNN, and rNN in horizontal EAs (thicknesses = 40mm) with downward heat flow direction.
- 2 September 2022
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 16 (1) , 57-71
Data-driven numerical models for the prediction of the thermal resistance value of the Enclosed Airspaces (EAs) in building envelopes
Enclosed airspaces (EAs) are a common component of different energy efficient technologies in building envelopes which have intrinsic adaptive behavior under various climatic conditions. The need for comprehensive accurate numerical models without restrictions for different applications still exists. Thus, for the first time, machine learning and regression-based techniques (Ordinary least squares Linear Regression (OLR), Support Vector Regression (SVR), Kernel Ridge Regression (KRR), k-Nearest Neighbors (kNN), r-Nearest Neighbors (rNN), and Artificial Neural Network (ANN)) were applied to develop precise models derived from the most credible experimental data with stochastic logic of testing and training in several runs. It was found that application of KRR, SVR, and ANN leads to the most desirable outcomes with highest R2 (0.97–0.99), and lowest errors, however OLR does not provide satisfactory results (R2 <0.6). Moreover, major deviations are observed for calculations by OLR, kNN, and rNN in horizontal EAs (thicknesses = 40mm) with downward heat flow direction.
- 25 February 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 207, 84-97
Evaluation of reflective insulation systems in wall application by guarded hot box apparatus, and comparative investigation with ASHRAE and ISO 15099
- 25 February 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 207, 84-97
Evaluation of reflective insulation systems in wall application by guarded hot box apparatus, and comparative investigation with ASHRAE and ISO 15099