Omnia Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Omnia Ali has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Maha Abdelmonem Hegazy
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
4 shared publications Azza A. Moustafa
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr-El Aini Street, 11562 Cairo, Egypt
3 shared publications- Dalia Mohamed
Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ein Helwan, 11795 Cairo, Egypt; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, October University for Modern Sciences and Arts, 11787 6 October City, Egypt
3 shared publications - Amr Mohamed Mahmoud
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo 11562, Egypt
2 shared publications Azza Aziz Moustafa
Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr-El Aini Street, 11562 Cairo, Egypt
2 shared publicationsHesham Salem
Analytical Chemistry Department, Faculty of Pharmacy, Deraya University, 14511 Cairo, Egypt
2 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 23496
A systematic stepwise optimization framework for rapid multi-analyte UPLC–MS/MS plasma analysis with integrated sustainability assessment
A stepwise optimization guidance model for rapid multi-analyte UPLC–MS/MS is proposed to report recurring limitations in bioanalytical method development. The model involves six stages: (1) physicochemical profiling, (2) extraction strategy selection, (3) chromatographic optimization, (4) mobile phase selection, (5) method validation, and (6) greenness evaluation. The applicability of this framework was demonstrated by determining Rifaximin, Ciprofloxacin, and Fluconazole in spiked human plasma, using Ibuprofen as an internal standard. Physicochemical profiling guided the selection of ionization mode and prediction of solubility behavior. Based on the model recommendations, liquid–liquid extraction using dichloromethane was selected to achieve effective analyte recovery. Chromatographic optimization and mobile phase selection through the proposed framework supported the use of rapid isocratic separation on a C18 column using a methanol/water mixture (95:5, v/v) as mobile phase. The method validation, performed as an integral stage of the workflow according to regulatory guidelines, demonstrated exceptional linearity (r² ≥ 0.999). The final stage of the model involved evaluating environmental applicability using AGSA and EPPI analyses. The proposed sequential framework is intended to serve as a methodological reference for analysts employing LC–MS/MS platforms, to establish a structured and reproducible analytical workflow that advances ecological sustainability in multi-analyte LC–MS/MS bioanalytical applications.
- 28 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 23496
Open AccessA systematic stepwise optimization framework for rapid multi-analyte UPLC–MS/MS plasma analysis with integrated sustainability assessment
A stepwise optimization guidance model for rapid multi-analyte UPLC–MS/MS is proposed to report recurring limitations in bioanalytical method development. The model involves six stages: (1) physicochemical profiling, (2) extraction strategy selection, (3) chromatographic optimization, (4) mobile phase selection, (5) method validation, and (6) greenness evaluation. The applicability of this framework was demonstrated by determining Rifaximin, Ciprofloxacin, and Fluconazole in spiked human plasma, using Ibuprofen as an internal standard. Physicochemical profiling guided the selection of ionization mode and prediction of solubility behavior. Based on the model recommendations, liquid–liquid extraction using dichloromethane was selected to achieve effective analyte recovery. Chromatographic optimization and mobile phase selection through the proposed framework supported the use of rapid isocratic separation on a C18 column using a methanol/water mixture (95:5, v/v) as mobile phase. The method validation, performed as an integral stage of the workflow according to regulatory guidelines, demonstrated exceptional linearity (r² ≥ 0.999). The final stage of the model involved evaluating environmental applicability using AGSA and EPPI analyses. The proposed sequential framework is intended to serve as a methodological reference for analysts employing LC–MS/MS platforms, to establish a structured and reproducible analytical workflow that advances ecological sustainability in multi-analyte LC–MS/MS bioanalytical applications.
- 24 July 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (14) , 147501
Electrochemical Sensor Based on Ferric Oxide/ Reduced Graphene Oxide Nanocomposite for Linezolid Determination
An innovative electrochemical sensor, constructed on a ferric oxide-reduced graphene oxide (Fe 2 O 3 /RGO) nanocomposite-modified carbon paste electrode, was developed for the determination of linezolid (LNZ) in pharmaceutical formulations. LZN is a critically important oxazolidinone antibiotic widely used to treat severe infections caused by multidrug-resistant Gram-positive pathogens. Owing to its narrow therapeutic index and the risk of dose-related adverse effects during prolonged therapy, sensitive and reliable analytical methods for its determination are essential to support quality control and therapeutic drug monitoring. The morphology and electrochemical behavior of the fabricated Fe 2 O 3 /RGO nanocomposite were evaluated. Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical behavior of LNZ at the modified electrode. Optimal analytical performance was accomplished systematically by adjusting different DPV experimental parameters. Under the optimized conditions, a linear response was revealed over the concentration range of 0.4–7.0 µ M, with a limit of detection of 0.152 µ M and a limit of quantification of 0.461 µ M was exhibited by the sensor. This method was successfully employed to the quantification of LNZ in pharmaceutical dosage forms, producing accurate and reproducible results. The developed sensor establishes high sensitivity, good repeatability, and satisfactory analytical performance, confirming its suitability for routine pharmaceutical analysis.
- 24 July 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (14) , 147501
Electrochemical Sensor Based on Ferric Oxide/ Reduced Graphene Oxide Nanocomposite for Linezolid Determination
An innovative electrochemical sensor, constructed on a ferric oxide-reduced graphene oxide (Fe 2 O 3 /RGO) nanocomposite-modified carbon paste electrode, was developed for the determination of linezolid (LNZ) in pharmaceutical formulations. LZN is a critically important oxazolidinone antibiotic widely used to treat severe infections caused by multidrug-resistant Gram-positive pathogens. Owing to its narrow therapeutic index and the risk of dose-related adverse effects during prolonged therapy, sensitive and reliable analytical methods for its determination are essential to support quality control and therapeutic drug monitoring. The morphology and electrochemical behavior of the fabricated Fe 2 O 3 /RGO nanocomposite were evaluated. Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical behavior of LNZ at the modified electrode. Optimal analytical performance was accomplished systematically by adjusting different DPV experimental parameters. Under the optimized conditions, a linear response was revealed over the concentration range of 0.4–7.0 µ M, with a limit of detection of 0.152 µ M and a limit of quantification of 0.461 µ M was exhibited by the sensor. This method was successfully employed to the quantification of LNZ in pharmaceutical dosage forms, producing accurate and reproducible results. The developed sensor establishes high sensitivity, good repeatability, and satisfactory analytical performance, confirming its suitability for routine pharmaceutical analysis.
- Open Access
- 3 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-13
Effective Removal of Levofloxacin from Pharmaceutical Wastewater Using Synthesized Zinc Oxid, Graphen Oxid Nanoparticles Compared with their Combination
The presence of antibiotic traces in the aquatic system due to the inefficient treatment of the pharmaceutical wastewater represented threats, such as bioaccumulation and antibiotic-resistance, to the environment and human health. Accordingly, for the first time, the current work utilized the photocatalytic degradation and the adsorption approach for Levofloxacin (LEVO) in pharmaceutical wastewater using new designed nano aspects. Therefore, spherical Zinc oxide nanoparticles (ZnONP) sized 17 nm and ultrathin sheet-like structure graphene oxide nanosheets (GONS) with layer thickness ~5 nm were fabricated separately or in a combination between them then characterized via Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Fourier Transforms Infrared Spectroscopy (FTIR), absorption spectra (UV-Vis) and Brunauer-Emmett-Teller (BET). Additionally, several parameters were investigated to evaluate the potential of the removal process, such as pH, the exposure time to UV radiation, the type and concentration of the nanoparticles (NPs) and the initial concentration of the drug using a mixed fractional factorial design. The most effective parameter for LEVO removal was the NPs type followed by the initial drug concentration. Furthermore, an RP-HPLC/UV method was developed and validated for measuring the percentage of removal for LEVO drug. The highest percentage removal for both 50 and 400 µg mL−1 LEVO was 99.2% and 99.6%, respectively, which was achieved using ZnONP/GONS combination at pH 9 ± 0.05 and UV light exposure time 120 min. In addition, the negative antibacterial activity of the treated wastewater sample confirmed the drug removal. The established protocol was successfully applied on wastewater samples collected from a pharmaceutical company that encouraged researchers to mainstream this design to be applied on other pharmaceutical wastewater drugs.
- 3 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-13
Open AccessEffective Removal of Levofloxacin from Pharmaceutical Wastewater Using Synthesized Zinc Oxid, Graphen Oxid Nanoparticles Compared with their Combination
The presence of antibiotic traces in the aquatic system due to the inefficient treatment of the pharmaceutical wastewater represented threats, such as bioaccumulation and antibiotic-resistance, to the environment and human health. Accordingly, for the first time, the current work utilized the photocatalytic degradation and the adsorption approach for Levofloxacin (LEVO) in pharmaceutical wastewater using new designed nano aspects. Therefore, spherical Zinc oxide nanoparticles (ZnONP) sized 17 nm and ultrathin sheet-like structure graphene oxide nanosheets (GONS) with layer thickness ~5 nm were fabricated separately or in a combination between them then characterized via Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Fourier Transforms Infrared Spectroscopy (FTIR), absorption spectra (UV-Vis) and Brunauer-Emmett-Teller (BET). Additionally, several parameters were investigated to evaluate the potential of the removal process, such as pH, the exposure time to UV radiation, the type and concentration of the nanoparticles (NPs) and the initial concentration of the drug using a mixed fractional factorial design. The most effective parameter for LEVO removal was the NPs type followed by the initial drug concentration. Furthermore, an RP-HPLC/UV method was developed and validated for measuring the percentage of removal for LEVO drug. The highest percentage removal for both 50 and 400 µg mL−1 LEVO was 99.2% and 99.6%, respectively, which was achieved using ZnONP/GONS combination at pH 9 ± 0.05 and UV light exposure time 120 min. In addition, the negative antibacterial activity of the treated wastewater sample confirmed the drug removal. The established protocol was successfully applied on wastewater samples collected from a pharmaceutical company that encouraged researchers to mainstream this design to be applied on other pharmaceutical wastewater drugs.
- Open Access
- 25 February 2019
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2019, 1-10
Functionalized Fe3O4Magnetic Nanoparticle Potentiometric Detection Strategy versus Classical Potentiometric Strategy for Determination of Chlorpheniramine Maleate and Pseudoephedrine HCl
Nanosized adsorbents when used in potentiometric methods of analysis usually show better performance rather than the traditional potentiometric approach; this is attributed to the high specific surface area of the nanomaterial used in addition to the lack of internal diffusion resistance, thus improving their adsorption capacity. In the presented work, a rapid and sensitive potentiometric determination of chlorpheniramine maleate (CPM) and pseudoephedrine hydrochloride (PSE) in pure form, in pharmaceutical preparation, and in biological fluid was developed based on functionalized magnetic nanoparticles (Fe3O4). This strategy was compared with the classical potentiometric strategy. Three types of sensors were constructed using phosphotungstic acid (PTA),β-cyclodextrin (β-CD), andβ-cyclodextrin-conjugated Fe3O4magnetic nanoparticles for the potentiometric determination of each of CPM and PSE. The prepared sensors were characterized in regards to their composition, life duration, working pH range, and response time. The sensors have demonstrated promising selectivity to CPM and PSE in the presence of pharmaceutical formulation excipients, plasma matrix, and a diversity of both organic and inorganic interfering materials. The developed sensors have displayed good responses. Statistical comparison of the achieved results with a reported method has revealed no significant difference regarding both accuracy and precision.
- 25 February 2019
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2019, 1-10
Open AccessFunctionalized Fe3O4Magnetic Nanoparticle Potentiometric Detection Strategy versus Classical Potentiometric Strategy for Determination of Chlorpheniramine Maleate and Pseudoephedrine HCl
Nanosized adsorbents when used in potentiometric methods of analysis usually show better performance rather than the traditional potentiometric approach; this is attributed to the high specific surface area of the nanomaterial used in addition to the lack of internal diffusion resistance, thus improving their adsorption capacity. In the presented work, a rapid and sensitive potentiometric determination of chlorpheniramine maleate (CPM) and pseudoephedrine hydrochloride (PSE) in pure form, in pharmaceutical preparation, and in biological fluid was developed based on functionalized magnetic nanoparticles (Fe3O4). This strategy was compared with the classical potentiometric strategy. Three types of sensors were constructed using phosphotungstic acid (PTA),β-cyclodextrin (β-CD), andβ-cyclodextrin-conjugated Fe3O4magnetic nanoparticles for the potentiometric determination of each of CPM and PSE. The prepared sensors were characterized in regards to their composition, life duration, working pH range, and response time. The sensors have demonstrated promising selectivity to CPM and PSE in the presence of pharmaceutical formulation excipients, plasma matrix, and a diversity of both organic and inorganic interfering materials. The developed sensors have displayed good responses. Statistical comparison of the achieved results with a reported method has revealed no significant difference regarding both accuracy and precision.
- 1 August 2018
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 31 (4) , 272-279
Simultaneous quantification of chlorpheniramine, pseudoephedrine, and ibuprofen in antitussive preparation by high-performance liquid chromatography and thin-layer chromatography–densitometric methods
Simple, accurate, precise, sensitive, and validated high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC)‒densitometric methods were developed for the simultaneous determination of chlorpheniramine maleate (CPM), pseudoephedrine HCl (PSE), and ibuprofen (IBF) in tablet dosage form. In method A, reversed-phase (RP)-HPLC analysis was performed on Zorbax C8 column (150 mm × 4.6 mm, 5 μm particle size i.d.), using a mobile phase consisting of methanol–acetonitrile–distilled water (pH 4) using orthophosphoric acid in the ratio (80:10:10, v/v) and flow rate of 0.7 mL min−1. Quantification was achieved with ultraviolet (UV) detection at 220 nm. In method B, TLC analysis was carried out on an aluminum-backed sheet of silica gel 60 F254 layer using ethyl acetate‒methanol‒ammonia (8:2:0.8, v/v) as the mobile phase. Quantification was carried out with UV detection at 262 nm. The validation of the proposed methods was applied according to the International Conference on Harmonization (ICH) guidelines. The suggested methods were successfully applied for the determination of the cited drugs in bulk powder and commercial dosage form.
- 1 August 2018
- Published by Akademiai Kiado Zrt. in JPC – Journal of Planar Chromatography – Modern TLC
- Vol. 31 (4) , 272-279
Simultaneous quantification of chlorpheniramine, pseudoephedrine, and ibuprofen in antitussive preparation by high-performance liquid chromatography and thin-layer chromatography–densitometric methods
Simple, accurate, precise, sensitive, and validated high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC)‒densitometric methods were developed for the simultaneous determination of chlorpheniramine maleate (CPM), pseudoephedrine HCl (PSE), and ibuprofen (IBF) in tablet dosage form. In method A, reversed-phase (RP)-HPLC analysis was performed on Zorbax C8 column (150 mm × 4.6 mm, 5 μm particle size i.d.), using a mobile phase consisting of methanol–acetonitrile–distilled water (pH 4) using orthophosphoric acid in the ratio (80:10:10, v/v) and flow rate of 0.7 mL min−1. Quantification was achieved with ultraviolet (UV) detection at 220 nm. In method B, TLC analysis was carried out on an aluminum-backed sheet of silica gel 60 F254 layer using ethyl acetate‒methanol‒ammonia (8:2:0.8, v/v) as the mobile phase. Quantification was carried out with UV detection at 262 nm. The validation of the proposed methods was applied according to the International Conference on Harmonization (ICH) guidelines. The suggested methods were successfully applied for the determination of the cited drugs in bulk powder and commercial dosage form.
- 1 February 2016
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 154, 76-83
Evaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrup
- 1 February 2016
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 154, 76-83
Evaluation of multivariate calibration models with different pre-processing and processing algorithms for a novel resolution and quantitation of spectrally overlapped quaternary mixture in syrup
- 1 February 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 137, 1363-1373
Evaluating the efficiency of spectral resolution of univariate methods manipulating ratio spectra and comparing to multivariate methods: An application to ternary mixture in common cold preparation
- 1 February 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 137, 1363-1373
Evaluating the efficiency of spectral resolution of univariate methods manipulating ratio spectra and comparing to multivariate methods: An application to ternary mixture in common cold preparation
- 2 November 2013
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 3 (5-6) , 342-358
Stability Indicating Spectrophotometric and Chemometric Methods for Determination of Buflomedil in Presence of its Acid Induced Degradation Products
Simple, accurate, sensitive, selective and validated UV spectrophotometric univariate and multivariate methods were developed for determination of Buflomedil (BFM) in presence of BFM degradation products (BFM Deg). The univariate methods includes mean centering of ratio spectra (MCR), ratio difference spectrophotometric method (RDSM) and H-point standard addition method (HPSAM); the first one used the amplitude at 235.7 nm, the second utilized the difference in amplitudes at 250 nm and 282 nm; while, the third method utilized the absorbance values at 247 and 282.4 nm. Linearity was obtained for the proposed methods in the ranges of 10–100 µgmL-1. The percentage recoveries were 100.06±0.963, 100.17±0.962 and 100.90±0.667 for the three methods in a respective order. Multivariate methods involves the application of three chemometric techniques, and classical least square (CLS) principal component regression (PCR) and partial least-squares regression (PLS), which were used for the simultaneous determination of the BFM and its degradation products. The results obtained from the proposed methods, together with the reported one, were statistically compared using one-way analysis of variance (ANOVA). These methods are suitable as stability indicating methods for the determination of BFM in presence of its degradation products either in bulk powder or in pharmaceutical formulations.
- 2 November 2013
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 3 (5-6) , 342-358
Stability Indicating Spectrophotometric and Chemometric Methods for Determination of Buflomedil in Presence of its Acid Induced Degradation Products
Simple, accurate, sensitive, selective and validated UV spectrophotometric univariate and multivariate methods were developed for determination of Buflomedil (BFM) in presence of BFM degradation products (BFM Deg). The univariate methods includes mean centering of ratio spectra (MCR), ratio difference spectrophotometric method (RDSM) and H-point standard addition method (HPSAM); the first one used the amplitude at 235.7 nm, the second utilized the difference in amplitudes at 250 nm and 282 nm; while, the third method utilized the absorbance values at 247 and 282.4 nm. Linearity was obtained for the proposed methods in the ranges of 10–100 µgmL-1. The percentage recoveries were 100.06±0.963, 100.17±0.962 and 100.90±0.667 for the three methods in a respective order. Multivariate methods involves the application of three chemometric techniques, and classical least square (CLS) principal component regression (PCR) and partial least-squares regression (PLS), which were used for the simultaneous determination of the BFM and its degradation products. The results obtained from the proposed methods, together with the reported one, were statistically compared using one-way analysis of variance (ANOVA). These methods are suitable as stability indicating methods for the determination of BFM in presence of its degradation products either in bulk powder or in pharmaceutical formulations.