Yuwang Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuwang Han has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hongman Zhang
College of chemistry and molecular engineering, Nanjing Tech University, Nanjing 211816, China
3 shared publications Lijiang Lei
College of Chemistry and Molecular Engineering, Nanjing Tech University, No. 30 Puzhu Road(S) Nanjing Jiangsu 211816 China
3 shared publicationsHui Feng
College of chemistry and molecular engineering, Nanjing Tech University, Nanjing 211816, China
2 shared publicationsYang Zhou
College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, P. R. China
2 shared publicationsGangqiang Xia
College of chemistry and molecular engineering, Nanjing Tech University, Nanjing 211816, China
1 shared publicationHongman Zhang
College of Chemistry and Molecular Engineering, Nanjing Tech University, No.30 Puzhu Road(S), Nanjing, 211816, China
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by MDPI AG in Spectroscopy Journal
- Vol. 4 (3) , 12
Simultaneous Determination of CH4, C2H6 and C2H4 Mixtures Using MCPSO-Optimized DKELM
Photoacoustic spectroscopy (PAS) is a highly sensitive and non-destructive technique widely used for trace gas detection; however, the simultaneous quantification of methane (CH4), ethane (C2H6), and ethylene (C2H4) remains challenging due to severe spectral cross-interference and non-linear responses across broad concentration ranges. In this work, we propose a high-precision, end-to-end detection framework based on a Deep Kernel Extreme Learning Machine (DKELM) optimized using a Mutation–Chaotic Particle Swarm Optimization (MCPSO) algorithm. To enhance diagnostic information in the photoacoustic signals, a multi-scale wavelet transform based on a db4 wavelet basis with 5-layer decomposition and a Heursure soft threshold strategy is first employed for denoising and enhancing absorption features. To address the hyperparameter sensitivity and local-optimum trapping inherent in deep models, the MCPSO algorithm integrates hybrid chaotic initialization, adaptive mutation probability control, Cauchy-based perturbation, temperature-controlled mutation amplitude, and elite-guided population updating. The proposed MCPSO-DKELM model is evaluated on an expanded dataset of 470 mixed-gas spectra and benchmarked against other frameworks, including the previously reported SVM-CPSO-KELM architecture. The experimental results demonstrate that MCPSO-DKELM achieves stable, segmentation-free quantification across the full dynamic range, with an average detection error below 3.5% and the maximum relative error constrained to under 15%, which represents a substantial improvement over existing approaches. Thus, the combination of deep kernel feature extraction and mutation–chaotic global optimization provides a robust and reliable solution for simultaneous multi-component hydrocarbon gas analysis in complex industrial environments.
- 24 June 2026
- Published by MDPI AG in Spectroscopy Journal
- Vol. 4 (3) , 12
Open AccessSimultaneous Determination of CH4, C2H6 and C2H4 Mixtures Using MCPSO-Optimized DKELM
Photoacoustic spectroscopy (PAS) is a highly sensitive and non-destructive technique widely used for trace gas detection; however, the simultaneous quantification of methane (CH4), ethane (C2H6), and ethylene (C2H4) remains challenging due to severe spectral cross-interference and non-linear responses across broad concentration ranges. In this work, we propose a high-precision, end-to-end detection framework based on a Deep Kernel Extreme Learning Machine (DKELM) optimized using a Mutation–Chaotic Particle Swarm Optimization (MCPSO) algorithm. To enhance diagnostic information in the photoacoustic signals, a multi-scale wavelet transform based on a db4 wavelet basis with 5-layer decomposition and a Heursure soft threshold strategy is first employed for denoising and enhancing absorption features. To address the hyperparameter sensitivity and local-optimum trapping inherent in deep models, the MCPSO algorithm integrates hybrid chaotic initialization, adaptive mutation probability control, Cauchy-based perturbation, temperature-controlled mutation amplitude, and elite-guided population updating. The proposed MCPSO-DKELM model is evaluated on an expanded dataset of 470 mixed-gas spectra and benchmarked against other frameworks, including the previously reported SVM-CPSO-KELM architecture. The experimental results demonstrate that MCPSO-DKELM achieves stable, segmentation-free quantification across the full dynamic range, with an average detection error below 3.5% and the maximum relative error constrained to under 15%, which represents a substantial improvement over existing approaches. Thus, the combination of deep kernel feature extraction and mutation–chaotic global optimization provides a robust and reliable solution for simultaneous multi-component hydrocarbon gas analysis in complex industrial environments.
- Open Access
- 1 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 3169
Methane, Ethylene, and Ethane Detection by Differential Helmholtz Resonance Spectroscopy Using a 3345 nm Mid-Infrared Tunable Diode Laser Source
Gas detection based on photoacoustic spectroscopy (PAS) has attracted extensive attention due to its high sensitivity and large range of linearity. Herein, to achieve the simultaneous detection of the light carbon gases (CH4, C2H4, and C2H6), a gas detection system was constructed using a single mid-infrared tunable diode laser (central wavelength 3345 nm) source based on differential Helmholtz resonance spectroscopy (DHRS). The detection parameters (driving current, modulation depth, phase angle, etc.) were optimized under ambient pressure using the 1f demodulation method. With an integration time of 2 s, the detection limit reached 98.8 ppb, 252 ppb, and 33 ppb for methane, ethylene, and ethane, respectively. The validation test of the three-component mixture shows that the cross-interference can be effectively reduced by multiwavelength linear regression, and single wavelength linear regression causes large errors in the quantification of methane and ethylene.
- 1 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 3169
Open AccessMethane, Ethylene, and Ethane Detection by Differential Helmholtz Resonance Spectroscopy Using a 3345 nm Mid-Infrared Tunable Diode Laser Source
Gas detection based on photoacoustic spectroscopy (PAS) has attracted extensive attention due to its high sensitivity and large range of linearity. Herein, to achieve the simultaneous detection of the light carbon gases (CH4, C2H4, and C2H6), a gas detection system was constructed using a single mid-infrared tunable diode laser (central wavelength 3345 nm) source based on differential Helmholtz resonance spectroscopy (DHRS). The detection parameters (driving current, modulation depth, phase angle, etc.) were optimized under ambient pressure using the 1f demodulation method. With an integration time of 2 s, the detection limit reached 98.8 ppb, 252 ppb, and 33 ppb for methane, ethylene, and ethane, respectively. The validation test of the three-component mixture shows that the cross-interference can be effectively reduced by multiwavelength linear regression, and single wavelength linear regression causes large errors in the quantification of methane and ethylene.
- 15 January 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (9) , 1015-1022
Detection of procalcitonin (PCT) using the double antibody sandwich method based on fluorescence resonance energy transfer between upconversion nanoparticles and quantum dots
A nanosensor is designed using a double antibody sandwich method based on fluorescence resonance energy transfer (FRET) between NaYF4 (Yb, Er) upconversion nanoparticles (UCNPs) and CdTe quantum dots (QDs) for the determination of procalcitonin (PCT). The UCNPs (donor) and CdTe QDs (acceptor) were modified separately with two PCT monoclonal antibodies, and they were bound together through a specific immune reaction via the addition of PCT antigen. The fluorescence intensity of UCNPs was quenched because of the resonant energy transferred between upconversion nanoparticles and quantum dots. Under the optimal conditions, the fluorescence quenching efficiency showed a linear response to the PCT concentration with values ranging from 0.1 to 10 ng mL−1 and a detection limit of 0.25 ng mL−1. This method can be easily extended to the double antibody sandwich assay with potential applications in in vitro diagnostics (IVD).
- 15 January 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (9) , 1015-1022
Detection of procalcitonin (PCT) using the double antibody sandwich method based on fluorescence resonance energy transfer between upconversion nanoparticles and quantum dots
A nanosensor is designed using a double antibody sandwich method based on fluorescence resonance energy transfer (FRET) between NaYF4 (Yb, Er) upconversion nanoparticles (UCNPs) and CdTe quantum dots (QDs) for the determination of procalcitonin (PCT). The UCNPs (donor) and CdTe QDs (acceptor) were modified separately with two PCT monoclonal antibodies, and they were bound together through a specific immune reaction via the addition of PCT antigen. The fluorescence intensity of UCNPs was quenched because of the resonant energy transferred between upconversion nanoparticles and quantum dots. Under the optimal conditions, the fluorescence quenching efficiency showed a linear response to the PCT concentration with values ranging from 0.1 to 10 ng mL−1 and a detection limit of 0.25 ng mL−1. This method can be easily extended to the double antibody sandwich assay with potential applications in in vitro diagnostics (IVD).
- 5 October 2017
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 35 (12) , 1861-1868
Rapid Detection of Serum Procalcitonin by Immunochromatograghy Technology Based on Freeze‐dried Up‐conversion Nanoparticles/Antibody Conjugates
- 5 October 2017
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 35 (12) , 1861-1868
Rapid Detection of Serum Procalcitonin by Immunochromatograghy Technology Based on Freeze‐dried Up‐conversion Nanoparticles/Antibody Conjugates
- 20 September 2016
- Published by Springer Nature in Journal of Fluorescence
- Vol. 26 (6) , 2237-2246
Preparation of K+-Doped Core-Shell NaYF4:Yb, Er Upconversion Nanoparticles and its Application for Fluorescence Immunochromatographic Assay of Human Procalcitonin
In the present study, we reported a convenient route to prepare well dispersed and functionalized K+-doped core-shell upconversion nanoparticles (UCP) by layer-by-layer (LbL) assembly of polyelectrolytes. UCP was firstly transferred to aqueous phase using cationic surfactant cetyl trimethyl ammonium bromide (CTAB) via hydrophobic interaction without removing the existing oleic acid (OA). Then the positively charged hydrophilic UCP@CTAB was further alternately deposited with negatively charged [poly (sodium 4-styrenesulfonate)] (PSS), positively charged [poly (allylamine hydrochloride)] (PAH) and negatively charged [poly (acrylic acid)] (PAA). The final carboxyl functionalized UCP@CTAB@PSS@PAH@PAA was then conjugated with monoclonal antibody1 (AB1) of procalcitonin (PCT), resulting in successful detection of PCT antigens based on the immunochromatographic assay (ICA). Linear response was achieved from 0 to 10 ng/mL, and the lowest limit of detection (LLD) was 0.18 ng/mL.
- 20 September 2016
- Published by Springer Nature in Journal of Fluorescence
- Vol. 26 (6) , 2237-2246
Preparation of K+-Doped Core-Shell NaYF4:Yb, Er Upconversion Nanoparticles and its Application for Fluorescence Immunochromatographic Assay of Human Procalcitonin
In the present study, we reported a convenient route to prepare well dispersed and functionalized K+-doped core-shell upconversion nanoparticles (UCP) by layer-by-layer (LbL) assembly of polyelectrolytes. UCP was firstly transferred to aqueous phase using cationic surfactant cetyl trimethyl ammonium bromide (CTAB) via hydrophobic interaction without removing the existing oleic acid (OA). Then the positively charged hydrophilic UCP@CTAB was further alternately deposited with negatively charged [poly (sodium 4-styrenesulfonate)] (PSS), positively charged [poly (allylamine hydrochloride)] (PAH) and negatively charged [poly (acrylic acid)] (PAA). The final carboxyl functionalized UCP@CTAB@PSS@PAH@PAA was then conjugated with monoclonal antibody1 (AB1) of procalcitonin (PCT), resulting in successful detection of PCT antigens based on the immunochromatographic assay (ICA). Linear response was achieved from 0 to 10 ng/mL, and the lowest limit of detection (LLD) was 0.18 ng/mL.