Anuj Chawla
Research Subjects
Anuj Chawla has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Michael Yam
Tan Tock Seng Hospital, Singapore, Singapore.
2 shared publications - Antony Xavier Rex Premchand
Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, 90 Yishun Central, Singapore 768828, Singapore
1 shared publication - Benjamin Joseph Kang
Singapore General Hospital, Singapore, Singapore
1 shared publication - Derek Howard Park
Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, 90 Yishun Central, Singapore 768828, Singapore
1 shared publication - Ernest Beng Kee Kwek
Department of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore
1 shared publication - Ernest Beng Kee Kwek
Department of Orthopaedic Surgery, Woodlands Health Campus, Singapore, Singapore
1 shared publication
Latest Publications
- 7 April 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (12) , 1939-1945
Cephalomedullary blade cut-ins: a poorly understood phenomenon
Objectives Proximal femoral nail antirotation (PFNA) cut-in is a unique phenomenon seen in pertrochanteric hip fractures treated with the PFNA. Cut-in refers to the superomedial migration of the proximal femoral blade into the femoral head and hip joint. We recognize that cut-in is a completely separate entity from the well-described cut-out failure. This study assesses relevant radiological and patient risks factors for cut-in. Design Retrospective multicenter study looking at patients with pertrochanteric hip fractures managed with the Synthes PFNA Setting Four tertiary hospitals over 7 years. Patients Patients with cut-ins were identified. Outcome measurement The radiological appearance of this mode of failure was assessed and compared to cut-outs. Patient demographics, fracture configuration, time to implant failure (cut-in), bone mineral density, tip–apex distance, neck–shaft angle and position of the tip of the helical blade in the femoral head were collected. Results There was a total of 1027 patients across 4 institutions with 23 patients with cut-in. Average neck–shaft angle was 133 degrees. 16 out of 19 patients had severe osteoporosis with BMD < − 2.5. 14 of 23 patients had poor placement of the blade. 13 of 23 had a tip–apex distance of more than 20 mm. Conclusion We propose a standardized nomenclature of “cut-in” for the phenomenon of superomedial migration of the proximal femoral blade. An anatomical neck–shaft reduction, accurate blade placement and increased surveillance for patients with severe osteoporosis are required to reduce the incidence and morbidity of cut-in.
- 7 April 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (12) , 1939-1945
Cephalomedullary blade cut-ins: a poorly understood phenomenon
Objectives Proximal femoral nail antirotation (PFNA) cut-in is a unique phenomenon seen in pertrochanteric hip fractures treated with the PFNA. Cut-in refers to the superomedial migration of the proximal femoral blade into the femoral head and hip joint. We recognize that cut-in is a completely separate entity from the well-described cut-out failure. This study assesses relevant radiological and patient risks factors for cut-in. Design Retrospective multicenter study looking at patients with pertrochanteric hip fractures managed with the Synthes PFNA Setting Four tertiary hospitals over 7 years. Patients Patients with cut-ins were identified. Outcome measurement The radiological appearance of this mode of failure was assessed and compared to cut-outs. Patient demographics, fracture configuration, time to implant failure (cut-in), bone mineral density, tip–apex distance, neck–shaft angle and position of the tip of the helical blade in the femoral head were collected. Results There was a total of 1027 patients across 4 institutions with 23 patients with cut-in. Average neck–shaft angle was 133 degrees. 16 out of 19 patients had severe osteoporosis with BMD < − 2.5. 14 of 23 patients had poor placement of the blade. 13 of 23 had a tip–apex distance of more than 20 mm. Conclusion We propose a standardized nomenclature of “cut-in” for the phenomenon of superomedial migration of the proximal femoral blade. An anatomical neck–shaft reduction, accurate blade placement and increased surveillance for patients with severe osteoporosis are required to reduce the incidence and morbidity of cut-in.