Jeongseok Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeongseok Oh has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chan Yeong Heo
Department of Plastic and Reconstructive Surgery, College of Medicine, Seoul National University, Seoul 03080, Republic of Korea
3 shared publications - Joon Seok Oh
National University College of Medicine, Seoul, Korea
2 shared publications - Seokchan Eun
Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea
2 shared publications - Ara Kim
Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Eon Ju Park
DI Plastic Surgery Clinic, Seoul, Korea
1 shared publication - Hee Chang Ahn
Department of Plastic and Reconstructive Surgery, Hanyang University College of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 13 December 2022
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 49 (06) , 740-744
Cranioplasty Using Three-Dimensional–Printed Polycaprolactone Implant and Free Latissimus Dorsi Musculocutaneous Flap in a Patient with Repeated Wound Problem following Titanium Cranioplasty
Titanium mesh is an alloplastic material widely used for the reconstruction of moderate-to-large skull defects. Repeated wound problems or infection following these reconstructions inevitably lead to the replacement of the cranioplasty material. Among the various alloplastic materials, polycaprolactone implants are usually used for the coverage of small defects such as burr holes. 1 Herein, we present a case of a large cranial defect successfully reconstructed with three-dimensional-printed polycaprolactone implant and a free latissimus dorsi musculocutaneous flap. Until 1-year follow-up, the patient showed a favorable esthetic outcome with no complications or wound relapse.
- 13 December 2022
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 49 (06) , 740-744
Open AccessCranioplasty Using Three-Dimensional–Printed Polycaprolactone Implant and Free Latissimus Dorsi Musculocutaneous Flap in a Patient with Repeated Wound Problem following Titanium Cranioplasty
Titanium mesh is an alloplastic material widely used for the reconstruction of moderate-to-large skull defects. Repeated wound problems or infection following these reconstructions inevitably lead to the replacement of the cranioplasty material. Among the various alloplastic materials, polycaprolactone implants are usually used for the coverage of small defects such as burr holes. 1 Herein, we present a case of a large cranial defect successfully reconstructed with three-dimensional-printed polycaprolactone implant and a free latissimus dorsi musculocutaneous flap. Until 1-year follow-up, the patient showed a favorable esthetic outcome with no complications or wound relapse.
- Open Access
- 31 January 2022
- Published by Korean Society for Aesthetic Plastic Surgery in Archives of Aesthetic Plastic Surgery
- Vol. 28 (1) , 9-16
Efficacy of breast augmentation using an external breast tissue expander for a shorter period while applying higher pressure: a preliminary study
Background Various types of external breast tissue expanders have been found to be effective for aesthetic breast augmentation. However, their use has been limited when compared with implant-based breast augmentation due to the burdensome nature of their application. This article reports the possibility that external breast tissue expanders may be applied safely and effectively with higher pressure and shorter application time.Methods The participants comprised patients who desired breast augmentation using the EVERA-RAPHA device between January 2020 and March 2020. A double-blinded prospective study was conducted on two groups of eight patients each, with either 60 mmHg or 100 mmHg of pressure applied. Standardized photographs were taken and blinded measurements of volume and circumference were made. The Mann-Whitney and paired t-tests were conducted.Results Sixteen patients were evaluated after 1 month of treatment. The women in groups 1 and 2 (60 mmHg and 100 mmHg, respectively) used EVERA-RAPHA for 15.400± 0.704 and 15.300±0.477 minutes per day, respectively. The mean volume increases in groups 1 and 2 were 39.000±42.526 cc and 27.700±20.260 cc, respectively. No patients dropped out of the study. All patients reported that the device was tolerable. Mild bruising was found in 62.5% of the patients in group 2.Conclusions Breast augmentation using external tissue expanders can be a safe, effective, and practical option. Pressures of 60 mmHg or 100 mmHg can be safely applied for a shorter duration. Larger studies are needed to further confirm our findings.
- 31 January 2022
- Published by Korean Society for Aesthetic Plastic Surgery in Archives of Aesthetic Plastic Surgery
- Vol. 28 (1) , 9-16
Open AccessEfficacy of breast augmentation using an external breast tissue expander for a shorter period while applying higher pressure: a preliminary study
Background Various types of external breast tissue expanders have been found to be effective for aesthetic breast augmentation. However, their use has been limited when compared with implant-based breast augmentation due to the burdensome nature of their application. This article reports the possibility that external breast tissue expanders may be applied safely and effectively with higher pressure and shorter application time.Methods The participants comprised patients who desired breast augmentation using the EVERA-RAPHA device between January 2020 and March 2020. A double-blinded prospective study was conducted on two groups of eight patients each, with either 60 mmHg or 100 mmHg of pressure applied. Standardized photographs were taken and blinded measurements of volume and circumference were made. The Mann-Whitney and paired t-tests were conducted.Results Sixteen patients were evaluated after 1 month of treatment. The women in groups 1 and 2 (60 mmHg and 100 mmHg, respectively) used EVERA-RAPHA for 15.400± 0.704 and 15.300±0.477 minutes per day, respectively. The mean volume increases in groups 1 and 2 were 39.000±42.526 cc and 27.700±20.260 cc, respectively. No patients dropped out of the study. All patients reported that the device was tolerable. Mild bruising was found in 62.5% of the patients in group 2.Conclusions Breast augmentation using external tissue expanders can be a safe, effective, and practical option. Pressures of 60 mmHg or 100 mmHg can be safely applied for a shorter duration. Larger studies are needed to further confirm our findings.
- Open Access
- 1 May 2020
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 47 (03) , 235-241
BellaGel breast implant: 6-Year results of a prospective cohort study
Background This is the first clinical study conducted among Asian women using breast implants manufactured by an Asian company. Four-year data regarding the safety and efficacy of BellaGel breast implants have already been published, and we now report 6-year data. Methods This study was designed to take place over 10 years. It included 103 patients who underwent breast reconstruction or augmentation using BellaGel breast implants. The rates of implant rupture and capsular contracture were measured and analyzed to evaluate the effectiveness of the breast implant. Results At patients’ 6-year postoperative visits, the implant rupture and capsular contracture rates were 1.15% and 2.30%, respectively. The implant rupture rate was 3.77% among reconstruction cases and 0% among augmentation cases. The capsular contracture rate was 5.66% among reconstruction cases and 0.83% among augmentation cases. Conclusions The 6-year data from this planned 10-year study suggest that the BellaGel cohesive silicone gel-filled breast implant is an effective and safe medical device that can be used in breast reconstruction and augmentation.
- 1 May 2020
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 47 (03) , 235-241
Open AccessBellaGel breast implant: 6-Year results of a prospective cohort study
Background This is the first clinical study conducted among Asian women using breast implants manufactured by an Asian company. Four-year data regarding the safety and efficacy of BellaGel breast implants have already been published, and we now report 6-year data. Methods This study was designed to take place over 10 years. It included 103 patients who underwent breast reconstruction or augmentation using BellaGel breast implants. The rates of implant rupture and capsular contracture were measured and analyzed to evaluate the effectiveness of the breast implant. Results At patients’ 6-year postoperative visits, the implant rupture and capsular contracture rates were 1.15% and 2.30%, respectively. The implant rupture rate was 3.77% among reconstruction cases and 0% among augmentation cases. The capsular contracture rate was 5.66% among reconstruction cases and 0.83% among augmentation cases. Conclusions The 6-year data from this planned 10-year study suggest that the BellaGel cohesive silicone gel-filled breast implant is an effective and safe medical device that can be used in breast reconstruction and augmentation.
- Open Access
- 20 February 2020
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 21 (1) , 69-72
Flap reconstruction of soft tissue defect after resecting a huge hemangioma of the nose
Hemangioma is a benign vascular tumor that grows by endothelial cell hyperplasia. It occurs most frequently in the head and neck region. Nose reconstruction is tricky because of its unique threedimensional structure and different tissue components. We report a case of successful reconstruction of near-total nose defect using the paramedian forehead flap combined with a nasolabial flap, immediately after excision of nasal hemangioma. A 49-year-old male patient was presented with a huge mass at the nose. Preoperative magnetic resonance imaging showed prominent vascular channels extending to the forehead and cheek. Complete resection of the mass was performed, which resulted in an eccentric defect. The right paramedian forehead flap and the left nasolabial flap were designed and transferred to the defect. Flap division was performed 1 month later. The patient is satisfied with the overall appearance and did not develop any functional deficit.
- 20 February 2020
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 21 (1) , 69-72
Open AccessFlap reconstruction of soft tissue defect after resecting a huge hemangioma of the nose
Hemangioma is a benign vascular tumor that grows by endothelial cell hyperplasia. It occurs most frequently in the head and neck region. Nose reconstruction is tricky because of its unique threedimensional structure and different tissue components. We report a case of successful reconstruction of near-total nose defect using the paramedian forehead flap combined with a nasolabial flap, immediately after excision of nasal hemangioma. A 49-year-old male patient was presented with a huge mass at the nose. Preoperative magnetic resonance imaging showed prominent vascular channels extending to the forehead and cheek. Complete resection of the mass was performed, which resulted in an eccentric defect. The right paramedian forehead flap and the left nasolabial flap were designed and transferred to the defect. Flap division was performed 1 month later. The patient is satisfied with the overall appearance and did not develop any functional deficit.
- 18 October 2019
- Published by Wiley in Microsurgery
- Vol. 40 (3) , 337-342
Extensive full thickness abdominal wall reconstruction using anterolateral thigh compound flap modifications
Purpose: Abdominal wall reconstruction is challenging, which demands adequate skin coverage and structural support. The anterolateral thigh (ALT) flap including fascial portion can be useful in such cases.Methods: Retrospective chart review of five patients that underwent complex abdominal wall defects reconstruction with ALT free flaps with fascia lata was conducted. Patient age ranged from 49 to 69 years (average: 57.4). The etiology of defects was infected liposuction site, small bowel perforation, esophageal cancer, diverticulum perforation, and Hartmann operation. The average size of the defect was 17.4 × 10 cm (9 × 9 ~ 21 × 18). Single‐stage reconstruction using ALT flaps based on the lateral circumflex femoral artery was done in all patients. Exposed intestines were successfully covered and reinforced utilizing fascial component.Results: The average size of the flap was 17.4 × 8 cm (9 × 9 cm ~25 × 10 cm). One partial flap necrosis, venous congestion, and infection occurred. These complications were treated successfully. During the follow‐up (12–96 months, mean: 63), all patients achieved functional stabilization and returned to normal activities.Conclusion: ALT flap combined with its fascial component is useful for abdominal wall. It can be a reliable option in cases of intestinal exposure.
- 18 October 2019
- Published by Wiley in Microsurgery
- Vol. 40 (3) , 337-342
Extensive full thickness abdominal wall reconstruction using anterolateral thigh compound flap modifications
Purpose: Abdominal wall reconstruction is challenging, which demands adequate skin coverage and structural support. The anterolateral thigh (ALT) flap including fascial portion can be useful in such cases.Methods: Retrospective chart review of five patients that underwent complex abdominal wall defects reconstruction with ALT free flaps with fascia lata was conducted. Patient age ranged from 49 to 69 years (average: 57.4). The etiology of defects was infected liposuction site, small bowel perforation, esophageal cancer, diverticulum perforation, and Hartmann operation. The average size of the defect was 17.4 × 10 cm (9 × 9 ~ 21 × 18). Single‐stage reconstruction using ALT flaps based on the lateral circumflex femoral artery was done in all patients. Exposed intestines were successfully covered and reinforced utilizing fascial component.Results: The average size of the flap was 17.4 × 8 cm (9 × 9 cm ~25 × 10 cm). One partial flap necrosis, venous congestion, and infection occurred. These complications were treated successfully. During the follow‐up (12–96 months, mean: 63), all patients achieved functional stabilization and returned to normal activities.Conclusion: ALT flap combined with its fascial component is useful for abdominal wall. It can be a reliable option in cases of intestinal exposure.
- Open Access
- 20 February 2019
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 20 (1) , 37-43
Exclusive tongue tip reconstruction of hemiglossectomy defects using the underrated lateral arm free flap with bilobed design
Tongue reconstruction is challenging with the unique function and anatomy. Goals for reconstruction differ depending on the extent of reconstruction. Thin and pliable flaps are useful for tongue tip reconstruction, for appearance and mobility. This study reports lateral arm free flap (LAFF) as a safe and optimal option for hemi-tongue reconstruction, especially for tongue tip after hemiglossectomy. Thirteen LAFFs were performed for hemi-tongue reconstruction after hemiglossectomy from 1995 to 2018. Of the 13 patients, seven were male and six were female, age varying from 24 to 64 years. All flaps healed uneventfully without complications. Donor sites were closed primarily. The recipient vessels for microvascular anastomosis were mainly superior thyroidal artery, external jugular vein. All patients returned to normal diet, with no complaints regarding reconstructed tongue and donor site. The LAFF is hairless, thin (especially with lateral epicondyle approach), and potentially sensate. They are advantageous features for tongue tip and hemi-tongue reconstruction. Donor site sacrifices the inessential posterior radial collateral artery, and the scar is hidden under short sleeve shirts. We believe that LAFF can be considered as the first choice flap for hemitongue reconstruction, over radial forearm free flaps.
- 20 February 2019
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 20 (1) , 37-43
Open AccessExclusive tongue tip reconstruction of hemiglossectomy defects using the underrated lateral arm free flap with bilobed design
Tongue reconstruction is challenging with the unique function and anatomy. Goals for reconstruction differ depending on the extent of reconstruction. Thin and pliable flaps are useful for tongue tip reconstruction, for appearance and mobility. This study reports lateral arm free flap (LAFF) as a safe and optimal option for hemi-tongue reconstruction, especially for tongue tip after hemiglossectomy. Thirteen LAFFs were performed for hemi-tongue reconstruction after hemiglossectomy from 1995 to 2018. Of the 13 patients, seven were male and six were female, age varying from 24 to 64 years. All flaps healed uneventfully without complications. Donor sites were closed primarily. The recipient vessels for microvascular anastomosis were mainly superior thyroidal artery, external jugular vein. All patients returned to normal diet, with no complaints regarding reconstructed tongue and donor site. The LAFF is hairless, thin (especially with lateral epicondyle approach), and potentially sensate. They are advantageous features for tongue tip and hemi-tongue reconstruction. Donor site sacrifices the inessential posterior radial collateral artery, and the scar is hidden under short sleeve shirts. We believe that LAFF can be considered as the first choice flap for hemitongue reconstruction, over radial forearm free flaps.