Ann-Sophie Vander Plaetsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ann-Sophie Vander Plaetsen has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Filip Van Nieuwerburgh
Laboratory of Pharmaceutical Biotechnology, Faculty of Pharmaceutical Sciences, Ghent University, Ghent, Belgium
10 shared publications - Dieter Deforce
Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, Gent, 9000, Belgium
8 shared publications - Senne Cornelis
Laboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium
6 shared publications - Jana Weymaere
Laboratory of Pharmaceutical Biotechnology, Ghent University, 9000 Gent, Belgium
3 shared publications Lieselot Deleye
Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium
3 shared publications- Olivier Tytgat
Faculty of Pharmaceutical Sciences, Ghent University
3 shared publications
Latest Publications
- Open Access
- 29 August 2024
- Published by Taylor & Francis in Artificial Cells, Nanomedicine, and Biotechnology
- Vol. 52 (1) , 426-436
High-throughput single-cell screening of viable hybridomas and patient-derived antibody-secreting cells using punchable microwells
Monoclonal antibodies (mAbs) hold significant potential as therapeutic agents and are invaluable tools in biomedical research. However, the lack of efficient high-throughput screening methods for single antibody-secreting cells (ASCs) has limited the diversity of available antibodies. Here, we introduce a novel, integrated workflow employing self-seeding microwells and an automated microscope-puncher system for the swift, high-throughput screening and isolation of single ASCs. The system allows for the individual screening and isolation of up to 6,400 cells within approximately one day, with the opportunity for parallelization and efficient upscaling. We successfully applied this workflow to both hybridomas and human patient-derived B cells, enabling subsequent clonal expansion or antibody sequence analysis through an optimized, single-cell nested reverse transcription-polymerase chain reaction (RT-PCR) procedure. By providing a time-efficient and more streamlined single ASC screening and isolation process, our workflow holds promise for driving forward progress in mAb development.
- 29 August 2024
- Published by Taylor & Francis in Artificial Cells, Nanomedicine, and Biotechnology
- Vol. 52 (1) , 426-436
Open AccessHigh-throughput single-cell screening of viable hybridomas and patient-derived antibody-secreting cells using punchable microwells
Monoclonal antibodies (mAbs) hold significant potential as therapeutic agents and are invaluable tools in biomedical research. However, the lack of efficient high-throughput screening methods for single antibody-secreting cells (ASCs) has limited the diversity of available antibodies. Here, we introduce a novel, integrated workflow employing self-seeding microwells and an automated microscope-puncher system for the swift, high-throughput screening and isolation of single ASCs. The system allows for the individual screening and isolation of up to 6,400 cells within approximately one day, with the opportunity for parallelization and efficient upscaling. We successfully applied this workflow to both hybridomas and human patient-derived B cells, enabling subsequent clonal expansion or antibody sequence analysis through an optimized, single-cell nested reverse transcription-polymerase chain reaction (RT-PCR) procedure. By providing a time-efficient and more streamlined single ASC screening and isolation process, our workflow holds promise for driving forward progress in mAb development.
- Open Access
- 12 January 2021
- Published by Wiley in Prenatal Diagnosis
- Vol. 41 (9) , 1171-1178
Enrichment of circulating trophoblasts from maternal blood using laminar microscale vortices
Objective Enrichment of circulating trophoblasts (CTs) from maternal blood at week 10 – 13 of gestation, using laminar microscale vortices, and evaluation of the performance of the VTX‐1 Liquid Biopsy System in terms of CT recovery and purity. Method 8 mL of blood was collected from 15 pregnant women and processed with the VTX‐1 Liquid Biopsy System. Y‐chromosome specific qPCR was performed to estimate the number of enriched male CTs. To evaluate the VTX‐1 performance, the target cell recovery was characterized by spiking experiments with a trophoblast cell line. Furthermore, the total quantity of DNA after enrichment was used to calculate the number of retained maternal cells. Results Successful recovery of male CTs was established in seven out of ten first trimester samples from pregnant women carrying a male fetus. The number of CTs, recovered from 8 mL of blood, was estimated between 2 and 6. Spiking experiments resulted in a CT recovery of ± 35 % with ± 1,524 retained maternal blood cells. Conclusion CTs can be enriched from maternal blood with high purity, using laminar microscale vortices, starting from 8 mL of blood.
- 12 January 2021
- Published by Wiley in Prenatal Diagnosis
- Vol. 41 (9) , 1171-1178
Open AccessEnrichment of circulating trophoblasts from maternal blood using laminar microscale vortices
Objective Enrichment of circulating trophoblasts (CTs) from maternal blood at week 10 – 13 of gestation, using laminar microscale vortices, and evaluation of the performance of the VTX‐1 Liquid Biopsy System in terms of CT recovery and purity. Method 8 mL of blood was collected from 15 pregnant women and processed with the VTX‐1 Liquid Biopsy System. Y‐chromosome specific qPCR was performed to estimate the number of enriched male CTs. To evaluate the VTX‐1 performance, the target cell recovery was characterized by spiking experiments with a trophoblast cell line. Furthermore, the total quantity of DNA after enrichment was used to calculate the number of retained maternal cells. Results Successful recovery of male CTs was established in seven out of ten first trimester samples from pregnant women carrying a male fetus. The number of CTs, recovered from 8 mL of blood, was estimated between 2 and 6. Spiking experiments resulted in a CT recovery of ± 35 % with ± 1,524 retained maternal blood cells. Conclusion CTs can be enriched from maternal blood with high purity, using laminar microscale vortices, starting from 8 mL of blood.
- Open Access
- 14 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Silicon µPCR Chip for Forensic STR Profiling with Hybeacon Probe Melting Curves
The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.
- 14 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessSilicon µPCR Chip for Forensic STR Profiling with Hybeacon Probe Melting Curves
The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.
- Open Access
- 26 February 2019
- Published by SAGE Publications in Tumor Biology
- Vol. 41 (2)
Feasibility of single-cell analysis of model cancer and foetal cells in blood after isolation by cell picking
The objective of the present feasibility study was to transfer single cell line cells to either microscopy slides for downstream immune characterization or to polymerase chain reaction tubes for downstream DNA quantitation. Tumour cell lines, SKBR3 and MCF7 and trophoblast cell line JEG-3 were spiked in healthy donor blood. The CytoTrack system was used to scan the spiked blood samples to identify target cells. Individual target cells were identified, picked by use of a CytoPicker and deposited to either a microscopic slide or a polymerase chain reaction tube (PCR). Single tumour cells on microscopic slides were further immunostained with human epidermal growth factor receptor 2 (Her2) and epithelial cell adhesion molecule (EpCAM). From the picked cells in polymerase chain reaction tubes, DNA was amplified, quantified and used for Short Tandem Repeat genotyping. Depositing rare cells to microscopy slides was laborious with only five cells per hour. In this study with a trained operator, the picked cells had an 80.5% recovery rate. Depositing single trophoblast cells in PCR tubes was a faster process with 10 cells in 5 min. Immunostaining of isolated cells by both Her2 and EpCAM was possible but showed varying staining intensity. Presence of trophoblasts and contaminating white blood cells in PCR tubes after cell picking was confirmed based on DNA yield and mixed Short Tandem Repeat profiles in five out of eight samples. Using the CytoPicker tool, single tumour and trophoblast cells were successfully isolated and moved from blood samples, allowing subsequent immunostaining or Short Tandem Repeat genotyping.
- 26 February 2019
- Published by SAGE Publications in Tumor Biology
- Vol. 41 (2)
Open AccessFeasibility of single-cell analysis of model cancer and foetal cells in blood after isolation by cell picking
The objective of the present feasibility study was to transfer single cell line cells to either microscopy slides for downstream immune characterization or to polymerase chain reaction tubes for downstream DNA quantitation. Tumour cell lines, SKBR3 and MCF7 and trophoblast cell line JEG-3 were spiked in healthy donor blood. The CytoTrack system was used to scan the spiked blood samples to identify target cells. Individual target cells were identified, picked by use of a CytoPicker and deposited to either a microscopic slide or a polymerase chain reaction tube (PCR). Single tumour cells on microscopic slides were further immunostained with human epidermal growth factor receptor 2 (Her2) and epithelial cell adhesion molecule (EpCAM). From the picked cells in polymerase chain reaction tubes, DNA was amplified, quantified and used for Short Tandem Repeat genotyping. Depositing rare cells to microscopy slides was laborious with only five cells per hour. In this study with a trained operator, the picked cells had an 80.5% recovery rate. Depositing single trophoblast cells in PCR tubes was a faster process with 10 cells in 5 min. Immunostaining of isolated cells by both Her2 and EpCAM was possible but showed varying staining intensity. Presence of trophoblasts and contaminating white blood cells in PCR tubes after cell picking was confirmed based on DNA yield and mixed Short Tandem Repeat profiles in five out of eight samples. Using the CytoPicker tool, single tumour and trophoblast cells were successfully isolated and moved from blood samples, allowing subsequent immunostaining or Short Tandem Repeat genotyping.
- Open Access
- 1 January 2019
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 38, 204-210
Forensic tri-allelic SNP genotyping using nanopore sequencing
- 1 January 2019
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 38, 204-210
Open AccessForensic tri-allelic SNP genotyping using nanopore sequencing
- Open Access
Forensic STR profiling using Oxford Nanopore Technologies’ MinION sequencer
Forensic STR profiling using massively parallel sequencing (MPS) has gained much attention as an alternative for the traditional capillary electrophoresis (CE) methods. Oxford Nanopore Technologies recently developed the ‘MinION’, a pocket-sized nanopore sequencer with promising features that could be useful in the field of forensic genetics. We applied this technology for forensic sequencing in a pilot study. Using standard STR primers, originally designed for multiplex PCR and CE, we developed a library preparation method suited for nanopore sequencing. Several analysis approaches were evaluated to explore the usefulness of the generated data: we developed and applied both a sequence-based and an amplicon length-based analysis on data originating from a 14-loci multiplex PCR on a single contributor DNA sample. Despite the high sequencing error rate, the analyses yielded partial forensic profiles with some useful evidential value.
Open AccessForensic STR profiling using Oxford Nanopore Technologies’ MinION sequencer
Forensic STR profiling using massively parallel sequencing (MPS) has gained much attention as an alternative for the traditional capillary electrophoresis (CE) methods. Oxford Nanopore Technologies recently developed the ‘MinION’, a pocket-sized nanopore sequencer with promising features that could be useful in the field of forensic genetics. We applied this technology for forensic sequencing in a pilot study. Using standard STR primers, originally designed for multiplex PCR and CE, we developed a library preparation method suited for nanopore sequencing. Several analysis approaches were evaluated to explore the usefulness of the generated data: we developed and applied both a sequence-based and an amplicon length-based analysis on data originating from a 14-loci multiplex PCR on a single contributor DNA sample. Despite the high sequencing error rate, the analyses yielded partial forensic profiles with some useful evidential value.
- Open Access
- 29 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-8
Multiplex STR amplification sensitivity in a silicon microchip
The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng–31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.
- 29 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-8
Open AccessMultiplex STR amplification sensitivity in a silicon microchip
The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng–31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.
- Open Access
- 19 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-6
Short Tandem Repeat analysis after Whole Genome Amplification of single B-lymphoblastoid cells
To allow multiple genetic analyses on a single cell, whole genome amplification (WGA) is required. Unfortunately, studies comparing different WGA methods for downstream human identification Short Tandem Repeat (STR) analysis remain absent. Therefore, the aim of this work was to assess the performance of four commercially available WGA kits for downstream human identification STR profiling on a B-lymphoblastoid cell line. The performance was assessed using an input of one or three micromanipulated cells. REPLI-g showed a very low dropout rate, as it was the only WGA method in this study that could provide a complete STR profile in some of its samples. Although Ampli1, DOPlify and PicoPLEX did not detect all selected STR markers, they seem suitable for genetic identification in single-cell applications.
- 19 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-6
Open AccessShort Tandem Repeat analysis after Whole Genome Amplification of single B-lymphoblastoid cells
To allow multiple genetic analyses on a single cell, whole genome amplification (WGA) is required. Unfortunately, studies comparing different WGA methods for downstream human identification Short Tandem Repeat (STR) analysis remain absent. Therefore, the aim of this work was to assess the performance of four commercially available WGA kits for downstream human identification STR profiling on a B-lymphoblastoid cell line. The performance was assessed using an input of one or three micromanipulated cells. REPLI-g showed a very low dropout rate, as it was the only WGA method in this study that could provide a complete STR profile in some of its samples. Although Ampli1, DOPlify and PicoPLEX did not detect all selected STR markers, they seem suitable for genetic identification in single-cell applications.
- Open Access
- 7 December 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-9
STR profiling and Copy Number Variation analysis on single, preserved cells using current Whole Genome Amplification methods
The growing interest in liquid biopsies for cancer research and cell-based non-invasive prenatal testing (NIPT) invigorates the need for improved single cell analysis. In these applications, target cells are extremely rare and fragile in peripheral circulation, which makes the genetic analysis very challenging. To overcome these challenges, cell stabilization and unbiased whole genome amplification are required. This study investigates the performance of four WGA methods on single or a limited number of cells after 24 hour of Streck Cell-Free DNA BCT preservation. The suitability of the DNA, amplified with Ampli1, DOPlify, PicoPLEX and REPLI-g, was assessed for both short tandem repeat (STR) profiling and copy number variant (CNV) analysis after shallow whole genome massively parallel sequencing (MPS). Results demonstrate that Ampli1, DOPlify and PicoPLEX perform well for both applications, with some differences between the methods. Samples amplified with REPLI-g did not result in suitable STR or CNV profiles, indicating that this WGA method is not able to generate high quality DNA after Streck Cell-Free DNA BCT stabilization of the cells.
- 7 December 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-9
Open AccessSTR profiling and Copy Number Variation analysis on single, preserved cells using current Whole Genome Amplification methods
The growing interest in liquid biopsies for cancer research and cell-based non-invasive prenatal testing (NIPT) invigorates the need for improved single cell analysis. In these applications, target cells are extremely rare and fragile in peripheral circulation, which makes the genetic analysis very challenging. To overcome these challenges, cell stabilization and unbiased whole genome amplification are required. This study investigates the performance of four WGA methods on single or a limited number of cells after 24 hour of Streck Cell-Free DNA BCT preservation. The suitability of the DNA, amplified with Ampli1, DOPlify, PicoPLEX and REPLI-g, was assessed for both short tandem repeat (STR) profiling and copy number variant (CNV) analysis after shallow whole genome massively parallel sequencing (MPS). Results demonstrate that Ampli1, DOPlify and PicoPLEX perform well for both applications, with some differences between the methods. Samples amplified with REPLI-g did not result in suitable STR or CNV profiles, indicating that this WGA method is not able to generate high quality DNA after Streck Cell-Free DNA BCT stabilization of the cells.
- Open Access
- 13 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-9
Performance of four modern whole genome amplification methods for copy number variant detection in single cells
Whole genome amplification (WGA) has become an invaluable tool to perform copy number variation (CNV) detection in single, or a limited number of cells. Unfortunately, current WGA methods introduce representation bias that limits the detection of small CNVs. New WGA methods have been introduced that might have the potential to reduce this bias. We compared the performance of PicoPLEX DNA-Seq (Picoseq), DOPlify, REPLI-g and Ampli-1 WGA for aneuploidy screening and copy number analysis using shallow whole genome massively parallel sequencing (MPS), starting from single or a limited number of cells. Although the four WGA methods perform differently, they are all suited for this application.
- 13 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-9
Open AccessPerformance of four modern whole genome amplification methods for copy number variant detection in single cells
Whole genome amplification (WGA) has become an invaluable tool to perform copy number variation (CNV) detection in single, or a limited number of cells. Unfortunately, current WGA methods introduce representation bias that limits the detection of small CNVs. New WGA methods have been introduced that might have the potential to reduce this bias. We compared the performance of PicoPLEX DNA-Seq (Picoseq), DOPlify, REPLI-g and Ampli-1 WGA for aneuploidy screening and copy number analysis using shallow whole genome massively parallel sequencing (MPS), starting from single or a limited number of cells. Although the four WGA methods perform differently, they are all suited for this application.