F. Avraham Dilmanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
F. Avraham Dilmanian has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
John G. Eley
Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
3 shared publicationsSunil Krishnan
Department of Radiation Oncology, MD Anderson Cancer Center
2 shared publicationsAdam Rusek
Brookhaven National Laboratory
1 shared publicationAllen G. Meek
1 shared publicationApril Vassantachart
Loma Linda University School of Medicine, Loma Linda, CA, USA
1 shared publication- Arthur L. Jenkins
Jenkins NeuroSpine, Private Practice, New York, NY, USA
1 shared publication
Latest Publications
- Open Access
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-15
Merging Orthovoltage X-Ray Minibeams spare the proximal tissues while producing a solid beam at the target
Conventional radiation therapy of brain tumors often produces cognitive deficits, particularly in children. We investigated the potential efficacy of merging Orthovoltage X-ray Minibeams (OXM). It segments the beam into an array of parallel, thin (~0.3 mm), planar beams, called minibeams, which are known from synchrotron x-ray experiments to spare tissues. Furthermore, the slight divergence of the OXM array make the individual minibeams gradually broaden, thus merging with their neighbors at a given tissue depth to produce a solid beam. In this way the proximal tissues, including the cerebral cortex, can be spared. Here we present experimental results with radiochromic films to characterize the method’s dosimetry. Furthermore, we present our Monte Carlo simulation results for physical absorbed dose, and a first-order biologic model to predict tissue tolerance. In particular, a 220-kVp orthovoltage beam provides a 5-fold sharper lateral penumbra than a 6-MV x-ray beam. The method can be implemented in arc-scan, which may include volumetric-modulated arc therapy (VMAT). Finally, OXM’s low beam energy makes it ideal for tumor-dose enhancement with contrast agents such as iodine or gold nanoparticles, and its low cost, portability, and small room-shielding requirements make it ideal for use in the low-and-middle-income countries.
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-15
Open AccessMerging Orthovoltage X-Ray Minibeams spare the proximal tissues while producing a solid beam at the target
Conventional radiation therapy of brain tumors often produces cognitive deficits, particularly in children. We investigated the potential efficacy of merging Orthovoltage X-ray Minibeams (OXM). It segments the beam into an array of parallel, thin (~0.3 mm), planar beams, called minibeams, which are known from synchrotron x-ray experiments to spare tissues. Furthermore, the slight divergence of the OXM array make the individual minibeams gradually broaden, thus merging with their neighbors at a given tissue depth to produce a solid beam. In this way the proximal tissues, including the cerebral cortex, can be spared. Here we present experimental results with radiochromic films to characterize the method’s dosimetry. Furthermore, we present our Monte Carlo simulation results for physical absorbed dose, and a first-order biologic model to predict tissue tolerance. In particular, a 220-kVp orthovoltage beam provides a 5-fold sharper lateral penumbra than a 6-MV x-ray beam. The method can be implemented in arc-scan, which may include volumetric-modulated arc therapy (VMAT). Finally, OXM’s low beam energy makes it ideal for tumor-dose enhancement with contrast agents such as iodine or gold nanoparticles, and its low cost, portability, and small room-shielding requirements make it ideal for use in the low-and-middle-income countries.
- Open Access
- 1 December 2015
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 5, 269
Charged Particle Therapy with Mini-Segmented Beams
One of the fundamental attributes of proton therapy and carbon ion therapy is the ability of these charged particles to spare tissue distal to the targeted tumor. This significantly reduces normal tissue toxicity and has the potential to translate to a wider therapeutic index. Although, in general, particle therapy also reduces dose to the proximal tissues, particularly in the vicinity of the target, dose to the skin and to other very superficial tissues tends to be higher than that of megavoltage x-rays. The methods presented here, namely, “interleaved carbon minibeams” and “radiosurgery with arrays of proton and light ion minibeams,” both utilize beams segmented into arrays of parallel “minibeams” of about 0.3 mm incident-beam size. These minibeam arrays spare tissues, as demonstrated by synchrotron x-ray experiments. An additional feature of particle minibeams is their gradual broadening due to multiple Coulomb scattering as they penetrate tissues. In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to “interleave” at the target to produce a solid radiation field within the target. As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared. The method was used in four-directional geometry at the NASA Space Radiation Laboratory to ablate a 6.5-mm target in a rabbit brain at a single exposure with 40 Gy physical absorbed dose. Contrast-enhanced magnetic resonance imaging and histology 6-month later showed very focal target necrosis with nearly no damage to the surrounding brain. As for minibeams of protons and light ions, for which the minibeam broadening is substantial, measurements at MD Anderson Cancer Center in Houston, TX, USA; and Monte Carlo simulations showed that the broadening minibeams will merge with their neighbors at a certain tissue depth to produce a solid beam to treat the target. The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues. This report describes these two methods and discusses their potential clinical applications.
- 1 December 2015
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 5, 269
Open AccessCharged Particle Therapy with Mini-Segmented Beams
One of the fundamental attributes of proton therapy and carbon ion therapy is the ability of these charged particles to spare tissue distal to the targeted tumor. This significantly reduces normal tissue toxicity and has the potential to translate to a wider therapeutic index. Although, in general, particle therapy also reduces dose to the proximal tissues, particularly in the vicinity of the target, dose to the skin and to other very superficial tissues tends to be higher than that of megavoltage x-rays. The methods presented here, namely, “interleaved carbon minibeams” and “radiosurgery with arrays of proton and light ion minibeams,” both utilize beams segmented into arrays of parallel “minibeams” of about 0.3 mm incident-beam size. These minibeam arrays spare tissues, as demonstrated by synchrotron x-ray experiments. An additional feature of particle minibeams is their gradual broadening due to multiple Coulomb scattering as they penetrate tissues. In the case of interleaved carbon minibeams, which do not broaden much, two arrays of planar carbon minibeams that remain parallel at target depth, are aimed at the target from 90° angles and made to “interleave” at the target to produce a solid radiation field within the target. As a result, the surrounding tissues are exposed only to individual carbon minibeam arrays and are therefore spared. The method was used in four-directional geometry at the NASA Space Radiation Laboratory to ablate a 6.5-mm target in a rabbit brain at a single exposure with 40 Gy physical absorbed dose. Contrast-enhanced magnetic resonance imaging and histology 6-month later showed very focal target necrosis with nearly no damage to the surrounding brain. As for minibeams of protons and light ions, for which the minibeam broadening is substantial, measurements at MD Anderson Cancer Center in Houston, TX, USA; and Monte Carlo simulations showed that the broadening minibeams will merge with their neighbors at a certain tissue depth to produce a solid beam to treat the target. The resulting sparing of proximal normal tissue allows radiosurgical ablative treatments with smaller impact on the skin and shallow tissues. This report describes these two methods and discusses their potential clinical applications.
- 1 January 2013
- Published by Radiation Research Society in Radiation Research
- Vol. 179 (1) , 76-88
X-Ray Microbeam Irradiation of the Contusion-Injured Rat Spinal Cord Temporarily Improves Hind-Limb Function
Spinal cord injury is a devastating condition with no effective treatment. The physiological processes that impede recovery include potentially detrimental immune responses and the production of reactive astrocytes. Previous work suggested that radiation treatment might be beneficial in spinal cord injury, although the method carries risk of radiation-induced damage. To overcome this obstacle we used arrays of parallel, synchrotron-generated X-ray microbeams (230 μm with 150 μm gaps between them) to irradiate an established model of rat spinal cord contusion injury. This technique is known to have a remarkable sparing effect in tissue, including the central nervous system. Injury was induced in adult female Long-Evans rats at the level of the thoracic vertebrae T9-T10 using 25 mm rod drop on an NYU Impactor. Microbeam irradiation was given to groups of 6-8 rats each, at either Day 10 (50 or 60 Gy in-beam entrance doses) or Day 14 (50, 60 or 70 Gy). The control group was comprised of two subgroups: one studied three months before the irradiation experiment (n = 9) and one at the time of the irradiations (n = 7). Hind-limb function was blindly scored with the Basso, Beattie and Bresnahan (BBB) rating scale on a nearly weekly basis. The scores for the rats irradiated at Day 14 post-injury, when using t test with 7-day data-averaging time bins, showed statistically significant improvement at 28-42 days post-injury (P < 0.038). H&E staining, tissue volume measurements and immunohistochemistry at day ≈ 110 post-injury did not reveal obvious differences between the irradiated and nonirradiated injured rats. The same microbeam irradiation of normal rats at 70 Gy in-beam entrance dose caused no behavioral deficits and no histological effects other than minor microglia activation at 110 days. Functional improvement in the 14-day irradiated group might be due to a reduction in populations of immune cells and/or reactive astrocytes, while the Day 10/Day 14 differences may indicate time-sensitive changes in these cells and their populations. With optimizations, including those of the irradiation time(s), microbeam pattern, dose, and perhaps concomitant treatments such as immunological intervention this method may ultimately reach clinical use.
- 1 January 2013
- Published by Radiation Research Society in Radiation Research
- Vol. 179 (1) , 76-88
X-Ray Microbeam Irradiation of the Contusion-Injured Rat Spinal Cord Temporarily Improves Hind-Limb Function
Spinal cord injury is a devastating condition with no effective treatment. The physiological processes that impede recovery include potentially detrimental immune responses and the production of reactive astrocytes. Previous work suggested that radiation treatment might be beneficial in spinal cord injury, although the method carries risk of radiation-induced damage. To overcome this obstacle we used arrays of parallel, synchrotron-generated X-ray microbeams (230 μm with 150 μm gaps between them) to irradiate an established model of rat spinal cord contusion injury. This technique is known to have a remarkable sparing effect in tissue, including the central nervous system. Injury was induced in adult female Long-Evans rats at the level of the thoracic vertebrae T9-T10 using 25 mm rod drop on an NYU Impactor. Microbeam irradiation was given to groups of 6-8 rats each, at either Day 10 (50 or 60 Gy in-beam entrance doses) or Day 14 (50, 60 or 70 Gy). The control group was comprised of two subgroups: one studied three months before the irradiation experiment (n = 9) and one at the time of the irradiations (n = 7). Hind-limb function was blindly scored with the Basso, Beattie and Bresnahan (BBB) rating scale on a nearly weekly basis. The scores for the rats irradiated at Day 14 post-injury, when using t test with 7-day data-averaging time bins, showed statistically significant improvement at 28-42 days post-injury (P < 0.038). H&E staining, tissue volume measurements and immunohistochemistry at day ≈ 110 post-injury did not reveal obvious differences between the irradiated and nonirradiated injured rats. The same microbeam irradiation of normal rats at 70 Gy in-beam entrance dose caused no behavioral deficits and no histological effects other than minor microglia activation at 110 days. Functional improvement in the 14-day irradiated group might be due to a reduction in populations of immune cells and/or reactive astrocytes, while the Day 10/Day 14 differences may indicate time-sensitive changes in these cells and their populations. With optimizations, including those of the irradiation time(s), microbeam pattern, dose, and perhaps concomitant treatments such as immunological intervention this method may ultimately reach clinical use.