Nora Sophie Marita Kuhnt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nora Sophie Marita Kuhnt has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ingo Nolte
Clinic for Small Animals, University of Veterinary Medicine Hannover, Foundation, 30559 Hannover, Germany
2 shared publications - Lisa Katharina Harder
Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, 30559 Hannover, Germany
2 shared publications - Matthias Lüpke
Institute for General Radiology and Medical Physics, University of Veterinary Medicine Hannover, Foundation, 30173 Hannover, Germany
2 shared publications - Patrick Wefstaedt
Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover
2 shared publications - Katharina Haverkamp
Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, D-30559, Hannover, Germany
1 shared publication - Katharina Haverkamp
Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Hannover, Germany
1 shared publication
Latest Publications
- Open Access
- 22 October 2019
- Published by Springer Nature in BMC Veterinary Research
- Vol. 15 (1) , 1-12
Evaluation of canine prostate volume in calculated tomographic images - comparison of two assessment methods
Background: Since most prostatic diseases are associated with the organ’s enlargement, evaluation of prostatic size is a main criterion in the diagnosis of prostatic state of health. While enlargement is a non-uniform process, volumetric measurements are believed to be advantageous to any single dimensional parameter for the diagnosis of prostatomegaly. In a previous study, volume was analysed with a slice addition technique (SAT), which was validated as highly accurate. Irrespective of high accuracy, SAT represents a complex and time-consuming procedure, which limits its clinical use. Thus, demand exists for more practical volume assessment methods. In this study, the prostatic volume of 95 canine patients (58 intact males, 37 neutered males) were analysed retrospectively by using the ellipsoid formula (Formula) and an imaging “wrap” function tool (Wrap) to help assess accuracy and applicability. Accuracy was checked against phantom measurements and results were compared to SAT measurements of the same patient pool obtained from a previously published paper. Patients were grouped according to prostatic structure (H = homogeneous, I = inhomogeneous, C = cystic) and volume using the SAT (volume group = vg: 1, 2 and 3). Results: High correlation between the Formula or Wrap volume and the phantom volume was found, the values being higher for the Formula. Mean Formula volumes (vg 1: 2.2 cm3, vg 2: 14.5 cm3, vg 3: 109.4 cm3, respectively) were significantly underestimated, while mean Wrap volumes (vg 1: 3.8 cm3, vg 2: 19.5 cm3, vg 3: 159.2 cm3) were statistically equivalent to SAT measurements (vg 1: 3.1 cm3, vg 2: 18.6 cm3, vg 3: 157.2 cm3, respectively). Differences between Formula and SAT volumes ranged from 22.4–31.1%, while differences between Wrap and SAT volumes were highest in small prostates (vg 1: 22.1%) and fell with increasing prostatic size (vg 3: 1.3%). Conclusion: The Wrap function is highly accurate, less time-consuming and complex compared to SAT and could serve as beneficial tool for measuring prostatic volume in clinical routine after further validation in future studies. The Formula method cannot be recommended as an alternative for volumetric measurements of the prostate gland due to its underestimation of volumes compared to SAT results.
- 22 October 2019
- Published by Springer Nature in BMC Veterinary Research
- Vol. 15 (1) , 1-12
Open AccessEvaluation of canine prostate volume in calculated tomographic images - comparison of two assessment methods
Background: Since most prostatic diseases are associated with the organ’s enlargement, evaluation of prostatic size is a main criterion in the diagnosis of prostatic state of health. While enlargement is a non-uniform process, volumetric measurements are believed to be advantageous to any single dimensional parameter for the diagnosis of prostatomegaly. In a previous study, volume was analysed with a slice addition technique (SAT), which was validated as highly accurate. Irrespective of high accuracy, SAT represents a complex and time-consuming procedure, which limits its clinical use. Thus, demand exists for more practical volume assessment methods. In this study, the prostatic volume of 95 canine patients (58 intact males, 37 neutered males) were analysed retrospectively by using the ellipsoid formula (Formula) and an imaging “wrap” function tool (Wrap) to help assess accuracy and applicability. Accuracy was checked against phantom measurements and results were compared to SAT measurements of the same patient pool obtained from a previously published paper. Patients were grouped according to prostatic structure (H = homogeneous, I = inhomogeneous, C = cystic) and volume using the SAT (volume group = vg: 1, 2 and 3). Results: High correlation between the Formula or Wrap volume and the phantom volume was found, the values being higher for the Formula. Mean Formula volumes (vg 1: 2.2 cm3, vg 2: 14.5 cm3, vg 3: 109.4 cm3, respectively) were significantly underestimated, while mean Wrap volumes (vg 1: 3.8 cm3, vg 2: 19.5 cm3, vg 3: 159.2 cm3) were statistically equivalent to SAT measurements (vg 1: 3.1 cm3, vg 2: 18.6 cm3, vg 3: 157.2 cm3, respectively). Differences between Formula and SAT volumes ranged from 22.4–31.1%, while differences between Wrap and SAT volumes were highest in small prostates (vg 1: 22.1%) and fell with increasing prostatic size (vg 3: 1.3%). Conclusion: The Wrap function is highly accurate, less time-consuming and complex compared to SAT and could serve as beneficial tool for measuring prostatic volume in clinical routine after further validation in future studies. The Formula method cannot be recommended as an alternative for volumetric measurements of the prostate gland due to its underestimation of volumes compared to SAT results.
- Open Access
- 4 February 2019
- Published by Springer Nature in BMC Veterinary Research
- Vol. 15 (1) , 1-11
Validation of canine prostate volumetric measurements in computed tomography determined by the slice addition technique using the Amira program
Prostatic diseases are common and mostly associated with enlargement of the accessory gland. Thus, determining the prostate size has become a main criterion for evaluating prostate health status. Computed tomography (CT) is recommended as a beneficial tool for evaluating prostate size, morphology and surrounding tissues. The purpose of this study was to establish an accurate procedure for volume estimation and afterwards evaluate the prostate volume in CT. Data of 95 dogs were analysed (58 male intact, 37 male neutered) using the slice addition technique with the Amira program. Accuracy of volumetric measurements by CT was validated by comparing them with those of phantoms of known volume. Patients were grouped according to age (< 4 yrs., 4–8 yrs., > 8 yrs) and prostate morphology in CT (H = homogeneous, I = inhomogeneous, C = cystic). The length of the sixth lumbar vertebra was measured to relate prostate volume to body size. This ratio was generated to compare prostate volume between the groups, irrespective of body size (ratio volume = Rv). A high correlation between the CT-derived and phantom volume was found. Overall, the mean prostate volume was 58.6 cm3. The mean ratio volume was 1.3 in intact male dogs, this being significantly higher than in neutered dogs (0.7). The lowest ratio volume values were found in group H for intact (Rv = 0.9) and neutered dogs (Rv = 0.6), followed by group I (intact: Rv = 1.1; neutered: Rv = 0.7) and C (intact: Rv = 1.4; neutered: Rv = 0.8). The length of the sixth lumbar vertebra was well correlated with the prostate volume (intact: r = 0.63, p < 0.001; neutered: r = 0.48, p = 0.003), while age exhibited a correlation only in intact dogs (r = 0.52, p < 0.001). The present study is pioneering in applying a slice addition technique to volumetric measurements of the prostate gland in CT, resulting in a highly precise method. Volumetric measurements of the canine prostate gland in CT images provide information about the prostate structure, castration status, age and body size of the patients. Therefore, prostate volume is a relevant parameter for evaluating prostate health status.
- 4 February 2019
- Published by Springer Nature in BMC Veterinary Research
- Vol. 15 (1) , 1-11
Open AccessValidation of canine prostate volumetric measurements in computed tomography determined by the slice addition technique using the Amira program
Prostatic diseases are common and mostly associated with enlargement of the accessory gland. Thus, determining the prostate size has become a main criterion for evaluating prostate health status. Computed tomography (CT) is recommended as a beneficial tool for evaluating prostate size, morphology and surrounding tissues. The purpose of this study was to establish an accurate procedure for volume estimation and afterwards evaluate the prostate volume in CT. Data of 95 dogs were analysed (58 male intact, 37 male neutered) using the slice addition technique with the Amira program. Accuracy of volumetric measurements by CT was validated by comparing them with those of phantoms of known volume. Patients were grouped according to age (< 4 yrs., 4–8 yrs., > 8 yrs) and prostate morphology in CT (H = homogeneous, I = inhomogeneous, C = cystic). The length of the sixth lumbar vertebra was measured to relate prostate volume to body size. This ratio was generated to compare prostate volume between the groups, irrespective of body size (ratio volume = Rv). A high correlation between the CT-derived and phantom volume was found. Overall, the mean prostate volume was 58.6 cm3. The mean ratio volume was 1.3 in intact male dogs, this being significantly higher than in neutered dogs (0.7). The lowest ratio volume values were found in group H for intact (Rv = 0.9) and neutered dogs (Rv = 0.6), followed by group I (intact: Rv = 1.1; neutered: Rv = 0.7) and C (intact: Rv = 1.4; neutered: Rv = 0.8). The length of the sixth lumbar vertebra was well correlated with the prostate volume (intact: r = 0.63, p < 0.001; neutered: r = 0.48, p = 0.003), while age exhibited a correlation only in intact dogs (r = 0.52, p < 0.001). The present study is pioneering in applying a slice addition technique to volumetric measurements of the prostate gland in CT, resulting in a highly precise method. Volumetric measurements of the canine prostate gland in CT images provide information about the prostate structure, castration status, age and body size of the patients. Therefore, prostate volume is a relevant parameter for evaluating prostate health status.