Jiawei Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiawei Shi has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Bingyu Wang
Department of Science and Education, The Affiliated TCM Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
1 shared publication- Bingyu Wang
NanFang Hospital, Guangzhou, China
1 shared publication - Cheng Liu
Department of Anesthesiology, Nan Fang Hospital, Southern Medical University, Guangzhou, China
1 shared publication ChongSen Lin
Department of Orthopedics, Huizhou Hospital of Guangzhou University of Chinese Medicine, Huicheng, Guangdong, China
1 shared publicationDandan Liu
Department of Respiratory Medicine, Taixing Hospital of TCM, Taixing, Jiangsu, China
1 shared publication- Dongbin Qu
Division of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China
1 shared publication
Latest Publications
- 4 September 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (2) , 559-571
LASSO-based machine learning algorithm for prediction of dysphagia in patients suffering anterior cervical discectomy and fusion
Purpose To develop and validate a predictive model for postoperative dysphagia in patients undergoing anterior cervical discectomy and fusion (ACDF). Methods We retrospectively analyzed 500 patients who underwent ACDF at our institution between 2018 and 2022. A total of 53 candidate predictors—including 21 radiographic measurements, 19 preoperative blood biomarkers, 9 medical history variables, and 4 surgical characteristics—were evaluated. Patients were randomly partitioned into a training cohort (75%, n = 375) and a validation cohort (25%, n = 125). We determine independent prognostic factors used univariate comparisons between dysphagia and non-dysphagia groups, the least absolute shrinkage and selection operator (LASSO) regression, receiver operating characteristic (ROC) curves analysis, followed by an interaction analysis. The LASSO regression model was applied for predictive signature building in the training set. Model performance was assessed by receiver operating characteristic (ROC) curve analysis, decision curve analysis (DCA), and calibration plots in both cohorts. Results Within one month after ACDF, 115 of 500 patients (23.0%) developed dysphagia. Univariate analysis yielded 37 variables associated with dysphagia. LASSO regression retained 13 predictors, and ROC analysis identified 30 variables with area under the curve (AUC) > 0.6. Intersecting these sets produced a final panel of 9 key predictors. The model achieved an AUC of 0.969 in the training cohort and 0.954 in the validation cohort. The DCA and calibration curve analysis showed good performance for the diagnostic model in both sets. Conclusion A LASSO-penalized logistic regression model incorporating radiographic parameters, blood biomarkers, medical history variables, and surgical characteristics accurately predicts postoperative dysphagia following ACDF and may guide individualized risk stratification.
- 4 September 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (2) , 559-571
LASSO-based machine learning algorithm for prediction of dysphagia in patients suffering anterior cervical discectomy and fusion
Purpose To develop and validate a predictive model for postoperative dysphagia in patients undergoing anterior cervical discectomy and fusion (ACDF). Methods We retrospectively analyzed 500 patients who underwent ACDF at our institution between 2018 and 2022. A total of 53 candidate predictors—including 21 radiographic measurements, 19 preoperative blood biomarkers, 9 medical history variables, and 4 surgical characteristics—were evaluated. Patients were randomly partitioned into a training cohort (75%, n = 375) and a validation cohort (25%, n = 125). We determine independent prognostic factors used univariate comparisons between dysphagia and non-dysphagia groups, the least absolute shrinkage and selection operator (LASSO) regression, receiver operating characteristic (ROC) curves analysis, followed by an interaction analysis. The LASSO regression model was applied for predictive signature building in the training set. Model performance was assessed by receiver operating characteristic (ROC) curve analysis, decision curve analysis (DCA), and calibration plots in both cohorts. Results Within one month after ACDF, 115 of 500 patients (23.0%) developed dysphagia. Univariate analysis yielded 37 variables associated with dysphagia. LASSO regression retained 13 predictors, and ROC analysis identified 30 variables with area under the curve (AUC) > 0.6. Intersecting these sets produced a final panel of 9 key predictors. The model achieved an AUC of 0.969 in the training cohort and 0.954 in the validation cohort. The DCA and calibration curve analysis showed good performance for the diagnostic model in both sets. Conclusion A LASSO-penalized logistic regression model incorporating radiographic parameters, blood biomarkers, medical history variables, and surgical characteristics accurately predicts postoperative dysphagia following ACDF and may guide individualized risk stratification.
- Open Access
- 26 May 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4220-4228
Pathogen detection in suspected spinal infection: metagenomic next-generation sequencing versus culture
Purpose: The aim is to compare the pathogen detection performance of metagenomic next-generation sequencing (mNGS) and the culturing of percutaneous needle biopsy samples obtained from an individual with a suspected spinal infection. Methods: A retrospective study of 141 individuals with a suspected spinal infection was conducted, and mNGS was performed. The microbial spectra and detection performance between mNGS and the culturing-based method were compared, and the effects of antibiotic intervention and biopsy on the detection performance were assessed. Results: The microorganisms isolated most commonly via the culturing-based method were Mycobacterium tuberculosis (n = 21), followed by Staphylococcus epidermidis (n = 13). The most common microorganisms detected via mNGS were Mycobacterium tuberculosis complex (MTBC) (n = 39), followed by Staphylococcus aureus (n = 15). The difference in the type of detected microorganisms between culturing and mNGS was observed only in Mycobacterium (P = 0.001). mNGS helped identify potential pathogens in 80.9% of cases, which was significantly higher than the positivity rate of 59.6% observed for the culturing-based method (P < 0.001). Moreover, mNGS had a sensitivity of 85.7% (95% CI, 78.4% to 91.3%), a specificity of 86.7% (95% CI, 59.5% to 98.3%), and sensitivity gains of 35% (85.7% vs. 50.8%; P < 0.001) during culturing, while no differences were observed in the specificity (86.7% vs. 93.3%; P = 0.543). In addition, antibiotic interventions significantly lowered the positivity rate of the culturing-based method (66.0% vs. 45.5%, P = 0.021) but had no effects on the results of mNGS (82.5% vs. 77.3%, P = 0.467). Conclusion: The use of mNGS could result in a higher detection rate compared to that observed with the culturing-based method in an individual with spinal infection and is particularly valuable for evaluating the effects of a mycobacterial infection or previous antibiotic intervention.
- 26 May 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4220-4228
Open AccessPathogen detection in suspected spinal infection: metagenomic next-generation sequencing versus culture
Purpose: The aim is to compare the pathogen detection performance of metagenomic next-generation sequencing (mNGS) and the culturing of percutaneous needle biopsy samples obtained from an individual with a suspected spinal infection. Methods: A retrospective study of 141 individuals with a suspected spinal infection was conducted, and mNGS was performed. The microbial spectra and detection performance between mNGS and the culturing-based method were compared, and the effects of antibiotic intervention and biopsy on the detection performance were assessed. Results: The microorganisms isolated most commonly via the culturing-based method were Mycobacterium tuberculosis (n = 21), followed by Staphylococcus epidermidis (n = 13). The most common microorganisms detected via mNGS were Mycobacterium tuberculosis complex (MTBC) (n = 39), followed by Staphylococcus aureus (n = 15). The difference in the type of detected microorganisms between culturing and mNGS was observed only in Mycobacterium (P = 0.001). mNGS helped identify potential pathogens in 80.9% of cases, which was significantly higher than the positivity rate of 59.6% observed for the culturing-based method (P < 0.001). Moreover, mNGS had a sensitivity of 85.7% (95% CI, 78.4% to 91.3%), a specificity of 86.7% (95% CI, 59.5% to 98.3%), and sensitivity gains of 35% (85.7% vs. 50.8%; P < 0.001) during culturing, while no differences were observed in the specificity (86.7% vs. 93.3%; P = 0.543). In addition, antibiotic interventions significantly lowered the positivity rate of the culturing-based method (66.0% vs. 45.5%, P = 0.021) but had no effects on the results of mNGS (82.5% vs. 77.3%, P = 0.467). Conclusion: The use of mNGS could result in a higher detection rate compared to that observed with the culturing-based method in an individual with spinal infection and is particularly valuable for evaluating the effects of a mycobacterial infection or previous antibiotic intervention.
- Open Access
- 7 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-9
Pedicle screw loosening: the value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgery
Pedicle screw loosening is a common complication after spine surgeries. Traditionally, it was assessed by radiological approaches, both X-ray and CT (computed tomography) scan, while reports using mechanical method to study screw loosening after spine surgery are rare. The primary objective was to study the prevalent of pedicle screw loosening according to extraction torque during screw removal surgery and access the sensitivity and specificity of both X-ray and CT scan for diagnosing screw loosening. The second objective was to identify the risk factors for low extraction torque of pedicle screw that might lead to loosening. Thirty-three patients who underwent pedicle screw removal surgery after at least 2 years from primary surgery were evaluated preoperatively for fixation stability by X-ray and CT scan. In total, 236 screws were taken out, and the extraction torque data was recorded and analyzed to identify the sensitivity and specificity of both imaging studies for screw loosening. Furthermore, risk factors that might contribute to low extraction torque were also studied. The mean extraction torque of removed screws was 1.55 ± 1.00 Nm; a torque force of less than 1.02 Nm was used to define a screw as loosened. According to such criterion, the loosening rate was found to be 33%. X-ray had a sensitivity of 24% and a specificity of 98%, while CT scan had a sensitivity of 22% and a specificity of 96%. Extraction torque of pedicle screws inserted in fractured vertebrae was significantly lower than those in non-fractured vertebrae (p = 0.009); meanwhile, screws of non-fusion surgery had lower extraction torque when compared to those in fusion surgery (p = 0.001). BMD (bone mineral density) and age had low but significant linear relationship with screw extraction torque (p = 0.01, R2 = 0.304; p = 0.045, R2 = 0.123). Our findings showed that both X-ray and CT scan had high specificity for screw loosening detection, but their sensitivities were relatively low. Surgeons needed to be more cautious when assessing screw loosening merely according to radiological examination, and aware of that screws in fractured vertebrae or non-fusion surgery were vulnerable to loosening.
- 7 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-9
Open AccessPedicle screw loosening: the value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgery
Pedicle screw loosening is a common complication after spine surgeries. Traditionally, it was assessed by radiological approaches, both X-ray and CT (computed tomography) scan, while reports using mechanical method to study screw loosening after spine surgery are rare. The primary objective was to study the prevalent of pedicle screw loosening according to extraction torque during screw removal surgery and access the sensitivity and specificity of both X-ray and CT scan for diagnosing screw loosening. The second objective was to identify the risk factors for low extraction torque of pedicle screw that might lead to loosening. Thirty-three patients who underwent pedicle screw removal surgery after at least 2 years from primary surgery were evaluated preoperatively for fixation stability by X-ray and CT scan. In total, 236 screws were taken out, and the extraction torque data was recorded and analyzed to identify the sensitivity and specificity of both imaging studies for screw loosening. Furthermore, risk factors that might contribute to low extraction torque were also studied. The mean extraction torque of removed screws was 1.55 ± 1.00 Nm; a torque force of less than 1.02 Nm was used to define a screw as loosened. According to such criterion, the loosening rate was found to be 33%. X-ray had a sensitivity of 24% and a specificity of 98%, while CT scan had a sensitivity of 22% and a specificity of 96%. Extraction torque of pedicle screws inserted in fractured vertebrae was significantly lower than those in non-fractured vertebrae (p = 0.009); meanwhile, screws of non-fusion surgery had lower extraction torque when compared to those in fusion surgery (p = 0.001). BMD (bone mineral density) and age had low but significant linear relationship with screw extraction torque (p = 0.01, R2 = 0.304; p = 0.045, R2 = 0.123). Our findings showed that both X-ray and CT scan had high specificity for screw loosening detection, but their sensitivities were relatively low. Surgeons needed to be more cautious when assessing screw loosening merely according to radiological examination, and aware of that screws in fractured vertebrae or non-fusion surgery were vulnerable to loosening.