Philippe Aubert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philippe Aubert has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Arash Najafi
Department of Radiology and Nuclear Medicine, Kantonsspital Winterthur, Winterthur, Switzerland
2 shared publications - Christoph A. Binkert
Department of Radiology and Nuclear Medicine, Cantonal Hospital Winterthur, Winterthur, Switzerland
2 shared publications - Katerina Koulia
Institute of Radiology and Nuclear Medicine, Kantonsspital Winterthur, Brauerstrasse 15, 8405, Winterthur, Switzerland
1 shared publication
Latest Publications
- 8 April 2019
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (7) , 1041-1044
Monomelic Ischemic Neuropathy of the Tibial and Peroneal Nerve After Onyx Embolization of Vasa Nervorum Supplying a Surgically Excluded Popliteal Artery Aneurysm
Ischemic neuropathy is an exceedingly rare complication after peripheral artery embolization. We report a case of ischemic damage to the tibial and peroneal nerve after embolization of the vasa nervorum that served as feeding collaterals to a surgically excluded popliteal artery aneurysm.
- 8 April 2019
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (7) , 1041-1044
Monomelic Ischemic Neuropathy of the Tibial and Peroneal Nerve After Onyx Embolization of Vasa Nervorum Supplying a Surgically Excluded Popliteal Artery Aneurysm
Ischemic neuropathy is an exceedingly rare complication after peripheral artery embolization. We report a case of ischemic damage to the tibial and peroneal nerve after embolization of the vasa nervorum that served as feeding collaterals to a surgically excluded popliteal artery aneurysm.
- Open Access
- 20 December 2018
- Published by Springer Nature in CVIR Endovascular
- Vol. 1 (1) , 1-4
Multi loop snare technique for difficult inferior vena cava filter retrievals
Use of optional vena cava filters has steadily increased. In the majority of cases removal is successful using standard techniques. In cases of tilting and migration of the filter however, more advanced techniques are necessary. The “loop-snare” technique has been described for such cases. Difficulties arise when the loop starts to slip around the legs and arms of the filter. We present an improved loop-snare technique which allows to retrieve IVC filters when the simple loop-snare technique fails. We used additional loops, in one case one additional loop in another case two additional loops around the filter tip which allowed successful retrieval. The additional loops were created with a reversed shaped catheter. All guidewires were then engaged with a snare and pulled into a large sheath. The additional loops stabilize the tip and the filter can be pulled into the sheath. The “multiple-loop-snare” technique is a refinement of the previously described “single loop-snare” technique and can be used when one loop fails.
- 20 December 2018
- Published by Springer Nature in CVIR Endovascular
- Vol. 1 (1) , 1-4
Open AccessMulti loop snare technique for difficult inferior vena cava filter retrievals
Use of optional vena cava filters has steadily increased. In the majority of cases removal is successful using standard techniques. In cases of tilting and migration of the filter however, more advanced techniques are necessary. The “loop-snare” technique has been described for such cases. Difficulties arise when the loop starts to slip around the legs and arms of the filter. We present an improved loop-snare technique which allows to retrieve IVC filters when the simple loop-snare technique fails. We used additional loops, in one case one additional loop in another case two additional loops around the filter tip which allowed successful retrieval. The additional loops were created with a reversed shaped catheter. All guidewires were then engaged with a snare and pulled into a large sheath. The additional loops stabilize the tip and the filter can be pulled into the sheath. The “multiple-loop-snare” technique is a refinement of the previously described “single loop-snare” technique and can be used when one loop fails.