Hisatake Okada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hisatake Okada has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yasushi Nakano
Corporate R&D Headquarters, Konica Minolta Inc
2 shared publications - Akiko Sato-Tadano
Department of Breast Surgery, Tohoku Kosai Hospital
1 shared publication - Armen Soukiazian
Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, USA
1 shared publication - Bradley M. Turner
University of Rochester Medical Center
1 shared publication - Brandon Buscaglia
Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, USA
1 shared publication - David G. Hicks
Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, 601 Elmwood Ave., Rochester, NY 14620, USA
1 shared publication
Latest Publications
- Open Access
- 13 May 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (5) , 114
Construction of a Non-Targeted Pattern Analysis Platform with Diverse Chemical Probe Arrays
Chemical probe-based pattern analysis offers a powerful approach for evaluating complex mixtures, particularly in non-target sensing scenarios where components are unknown or where multivariate interactions, such as those involved in taste perception, dominate the response behavior. However, its broader applicability has been limited by challenges in generating sufficiently diverse probe sets and in acquiring multidimensional response data from large probe arrays. In this study, we address both limitations by constructing a high-capacity sensing platform that integrates artificial DNA-derived chemical probes with conventional fluorescent probes. Artificial DNA probes were synthesized following established modular assembly methods, enabling large-scale generation of structurally diverse sensing elements. An imaging-based detection instrument—combining controlled excitation and high-resolution fluorescence capture—was developed to simultaneously quantify color and intensity responses from up to 88 probes. We applied this system to the analysis of 20 taste-related compounds, demonstrating clear discrimination based on multidimensional fluorescence patterns. Furthermore, systematic evaluation of probe number versus classification accuracy revealed that increased probe diversity substantially enhances non-target discrimination performance, supporting the value of using low-specificity artificial DNA probes in high-density arrays. These results establish a versatile and scalable platform for non-target pattern analysis and highlight the importance of probe multiplicity in complex mixture sensing.
- 13 May 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (5) , 114
Open AccessConstruction of a Non-Targeted Pattern Analysis Platform with Diverse Chemical Probe Arrays
Chemical probe-based pattern analysis offers a powerful approach for evaluating complex mixtures, particularly in non-target sensing scenarios where components are unknown or where multivariate interactions, such as those involved in taste perception, dominate the response behavior. However, its broader applicability has been limited by challenges in generating sufficiently diverse probe sets and in acquiring multidimensional response data from large probe arrays. In this study, we address both limitations by constructing a high-capacity sensing platform that integrates artificial DNA-derived chemical probes with conventional fluorescent probes. Artificial DNA probes were synthesized following established modular assembly methods, enabling large-scale generation of structurally diverse sensing elements. An imaging-based detection instrument—combining controlled excitation and high-resolution fluorescence capture—was developed to simultaneously quantify color and intensity responses from up to 88 probes. We applied this system to the analysis of 20 taste-related compounds, demonstrating clear discrimination based on multidimensional fluorescence patterns. Furthermore, systematic evaluation of probe number versus classification accuracy revealed that increased probe diversity substantially enhances non-target discrimination performance, supporting the value of using low-specificity artificial DNA probes in high-density arrays. These results establish a versatile and scalable platform for non-target pattern analysis and highlight the importance of probe multiplicity in complex mixture sensing.
- Open Access
Automated Quantification of Extranuclear ERα Using Phosphor-Integrated Dots for Predicting Endocrine Therapy Resistance in HR+/HER2− Breast Cancer
In addition to genomic signaling, Estrogen receptor alpha (ERα) is associated with cell proliferation and survival through extranuclear signaling contributing to endocrine therapy (ET) resistance. However, the relationship between extranuclear ERα and ET resistance has not been extensively studied. We sought to measure extranuclear ERα expression by immunohistochemistry using phosphor-integrated dots (IHC-PIDs) and to assess its predictive value for ET resistance. After quantitative detection of ERα by IHC-PIDs in vitro, we developed “the nearest-neighbor method” to calculate the extranuclear ERα. Furthermore, tissue sections from 65 patients with HR+/HER2- BC were examined by IHC-PIDs, and the total ERα, nuclear ERα, extranuclear ERα PIDs score, and ratio of extranuclear-to-nuclear ERα (ENR) were measured using the novel method. We demonstrate that quantification of ERα using IHC-PIDs exhibited strong correlations to real-time qRT-PCR (r2 = 0.94) and flow cytometry (r2 = 0.98). High ERα ENR was significantly associated with poor overall survival (p = 0.048) and disease-free survival (DFS) (p = 0.007). Multivariate analysis revealed that the ERα ENR was an independent prognostic factor for DFS [hazard ratio, 3.8; 95% CI, 1.4–11.8; p = 0.006]. Our automated measurement has high accuracy to localize and assess extranuclear ERα. A high ERα ENR in HR+/HER2− BC indicates decreased likelihood of benefiting from ET.
Open AccessAutomated Quantification of Extranuclear ERα Using Phosphor-Integrated Dots for Predicting Endocrine Therapy Resistance in HR+/HER2− Breast Cancer
In addition to genomic signaling, Estrogen receptor alpha (ERα) is associated with cell proliferation and survival through extranuclear signaling contributing to endocrine therapy (ET) resistance. However, the relationship between extranuclear ERα and ET resistance has not been extensively studied. We sought to measure extranuclear ERα expression by immunohistochemistry using phosphor-integrated dots (IHC-PIDs) and to assess its predictive value for ET resistance. After quantitative detection of ERα by IHC-PIDs in vitro, we developed “the nearest-neighbor method” to calculate the extranuclear ERα. Furthermore, tissue sections from 65 patients with HR+/HER2- BC were examined by IHC-PIDs, and the total ERα, nuclear ERα, extranuclear ERα PIDs score, and ratio of extranuclear-to-nuclear ERα (ENR) were measured using the novel method. We demonstrate that quantification of ERα using IHC-PIDs exhibited strong correlations to real-time qRT-PCR (r2 = 0.94) and flow cytometry (r2 = 0.98). High ERα ENR was significantly associated with poor overall survival (p = 0.048) and disease-free survival (DFS) (p = 0.007). Multivariate analysis revealed that the ERα ENR was an independent prognostic factor for DFS [hazard ratio, 3.8; 95% CI, 1.4–11.8; p = 0.006]. Our automated measurement has high accuracy to localize and assess extranuclear ERα. A high ERα ENR in HR+/HER2− BC indicates decreased likelihood of benefiting from ET.
- Open Access
- 18 December 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1266
A novel detection methodology for HER2 protein quantitation in formalin-fixed, paraffin embedded clinical samples using fluorescent nanoparticles: an analytical and clinical validation study
Clinical assays for the assessment of the human epidermal growth factor receptor-2 (HER2) status in breast cancer include immunohistochemistry (IHC) and in situ hybridization (ISH), both of which have limitations. Recent studies have suggested that a more quantitative approach to the measurement of HER2 protein expression may improve specificity in selecting patients for HER-2 targeted therapy. In the current study, we have used HER2 expression in breast cancer cell lines and clinical samples as a model to explore the potential utility of a novel immunodetection technique, using streptavidin coated Phosphor Integrated Dot fluorescent nanoparticles (PID), which can be quantitatively measured using computer analysis. The expression of HER2 protein in cell lines was evaluated with antibody-binding capacity using fluorescence-activated cell sorting (FACS) for comparison with PID measurements to test for correlations with existing quantitative protein analysis methodologies. Various other analytic validation tests were also performed, including accuracy, precision, sensitivity, robustness and reproducibility. A methods comparison study investigated correlations between PID versus IHC and ISH in clinical samples. Lastly, we measured HER2 protein expression using PID in the pretreatment biopsies from 34 HER2-positive carcinomas that had undergone neoadjuvant trastuzumab-based chemotherapy. In the analytic validation, PID HER2 measurements showed a strong linear correlation with FACS analysis in breast cell lines, and demonstrated significant correlations with all aspects of precision, sensitivity, robustness and reproducibility. PID also showed strong correlations with conventional HER2 testing methodologies (IHC and ISH). In the neoadjuvant study, patients with a pathologic complete response (pCR) had a significantly higher PID score compared with patients who did not achieve a pCR (p = 0.011), and was significantly correlated to residual cancer burden (RCB) class (p = 0.026, R2 = 0.9975). Analytic testing of PID showed that it may be a viable testing methodology that could offer advantages over other experimental or conventional biomarker diagnostic methodologies. Our data also suggests that PID quantitation of HER2 protein may offer an improvement over conventional HER2 testing in the selection of patients who will be the most likely to benefit from HER2-targeted therapy. Further studies with a larger cohort are warranted.
- 18 December 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1266
Open AccessA novel detection methodology for HER2 protein quantitation in formalin-fixed, paraffin embedded clinical samples using fluorescent nanoparticles: an analytical and clinical validation study
Clinical assays for the assessment of the human epidermal growth factor receptor-2 (HER2) status in breast cancer include immunohistochemistry (IHC) and in situ hybridization (ISH), both of which have limitations. Recent studies have suggested that a more quantitative approach to the measurement of HER2 protein expression may improve specificity in selecting patients for HER-2 targeted therapy. In the current study, we have used HER2 expression in breast cancer cell lines and clinical samples as a model to explore the potential utility of a novel immunodetection technique, using streptavidin coated Phosphor Integrated Dot fluorescent nanoparticles (PID), which can be quantitatively measured using computer analysis. The expression of HER2 protein in cell lines was evaluated with antibody-binding capacity using fluorescence-activated cell sorting (FACS) for comparison with PID measurements to test for correlations with existing quantitative protein analysis methodologies. Various other analytic validation tests were also performed, including accuracy, precision, sensitivity, robustness and reproducibility. A methods comparison study investigated correlations between PID versus IHC and ISH in clinical samples. Lastly, we measured HER2 protein expression using PID in the pretreatment biopsies from 34 HER2-positive carcinomas that had undergone neoadjuvant trastuzumab-based chemotherapy. In the analytic validation, PID HER2 measurements showed a strong linear correlation with FACS analysis in breast cell lines, and demonstrated significant correlations with all aspects of precision, sensitivity, robustness and reproducibility. PID also showed strong correlations with conventional HER2 testing methodologies (IHC and ISH). In the neoadjuvant study, patients with a pathologic complete response (pCR) had a significantly higher PID score compared with patients who did not achieve a pCR (p = 0.011), and was significantly correlated to residual cancer burden (RCB) class (p = 0.026, R2 = 0.9975). Analytic testing of PID showed that it may be a viable testing methodology that could offer advantages over other experimental or conventional biomarker diagnostic methodologies. Our data also suggests that PID quantitation of HER2 protein may offer an improvement over conventional HER2 testing in the selection of patients who will be the most likely to benefit from HER2-targeted therapy. Further studies with a larger cohort are warranted.