YKYuki Kato

Yuki Kato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuki Kato has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Shuzo Takazawa

    Department of Sports Medicine, Kameda Medical Center, Chiba, JPN

    10 shared publications
  • Shin Yamada

    Joint Preservation & Reconstruction Center, Kameda Medical Center, 929 Higashi-Cho, Kamogawa City, Chiba Prefecture, 296-8602, Japan; Department of Sports Medicine, Kameda Medical Center, 929 Higashi-Cho, Kamogawa City, Chiba Prefecture, 296-8602, Japan

    8 shared publications
  • Soichi Hattori

    Department of Sports Medicine, Kameda Medical Center, Kamogawa City, Japan

    7 shared publications
  • Hiroshi Ohuchi

    Department of Sports Medicine, Kameda Medical Center, 929 Higashi-Cho, Kamogawa City, Chiba Prefecture, 296-8602, Japan

    5 shared publications
  • Hiroshi Ohuchi

    Department of Sports Medicine Kameda Medical Center Kamogawa Chiba Japan

    5 shared publications
  • Takuya Adachi

    Department of Sports Medicine, Kameda Medical Center, Chiba, JPN

    4 shared publications

Latest Publications

  • Open Access

    Bidirectional joint line convergence angle changes and their preoperative predictors 12 months after medial closing‐wedge distal femoral osteotomy for valgus knees: A single‐centre exploratory study

    by Yuki Kato, Ken Ichikawa, Hiroki Matsui, Shuzo Takazawa, Shunsuke Koga, Shin Yamada, Asami Kiuchi, Akira Ryu, Hiroshi Ohuchi

    Purpose: To characterize the signed 12‐month change in joint line convergence angle (JLCA) after medial closing‐wedge distal femoral osteotomy (MCWDFO) for valgus knees and assess associations with preoperative factors, particularly its preoperative value. Methods: This retrospective single‐centre cohort included 62 knees treated with MCWDFO between October 2017 and December 2024 without additional osteotomy or ligament repair or reconstruction. The primary outcome was signed change (12‐month postoperative minus preoperative JLCA) on weight‐bearing full‐length radiographs. Univariable and multivariable linear regression analyses were performed. The primary model included preoperative JLCA, mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), age, sex and body mass index (BMI). Cluster‐robust standard errors accounted for within‐patient dependence (eight bilateral patients). Internal performance was assessed using patient‐grouped 10‐fold cross‐validation (50 repeats), pooling out‐of‐fold predictions within each repeat. Results: Preoperative JLCA was −1.13 ± 2.04° and the 12‐month value was −0.56 ± 1.61°, with postoperative values more concentrated near 0°. Mean signed change was 0.57 ± 1.90° (median, 0.3°; range, −4.6° to 6.9°). Preoperative JLCA showed the strongest association with signed change (coefficient, −0.56; 95% confidence interval, −0.78 to −0.34; p < 0.001). mMPTA was also independently associated, whereas mLDFA, age, sex and BMI were not. Primary and cross‐validated coefficients of determination were 0.602 and 0.474; cross‐validated root mean squared and mean absolute errors were 1.36° and 1.10°. Conclusions: Signed change showed substantial between‐knee variability despite a small mean change. The association with preoperative JLCA should be interpreted cautiously because of mathematical coupling. The model showed moderate internal predictive performance and remains exploratory rather than a precise individual‐level prediction tool. External validation and formal radiographic reliability assessment are required before clinical implementation. Level of Evidence: Level III, retrospective cohort study.

  • Open Access

    Histological effects of intra-articular allogeneic leukocyte-rich and leukocyte-poor platelet-rich plasma in healthy rabbit knees: an exploratory study

    by Yuki Kato, Shinobu Yanada, Hitoshi Morikawa, Airi Ota

    Platelet-rich plasma (PRP) is used to treat knee osteoarthritis and cartilage injuries, but its effects on healthy joint tissues are unclear. This explorat

  • Open Access

    Trochlear cartilage status at second‐look arthroscopy predicts 2‐year outcomes after around‐knee osteotomy, especially in older patients

    by Yuki Kato, Ken Ichikawa, Hiroki Matsui, Shuzo Takazawa, Shin Yamada, Takuya Okada, Akira Ryu, Hiroshi Ohuchi

    Purpose: To investigate whether trochlear surface cartilage degeneration of the patellofemoral joint, assessed by second‐look arthroscopy after around‐knee osteotomy (AKO), affects postoperative patient‐reported outcomes and to examine the influence of patient age on this relationship. Methods: This retrospective cohort study included 331 patients who underwent AKO for varus knee deformity between November 2016 and June 2022. Second‐look arthroscopy was performed approximately 1 year postoperatively, and patients were classified according to femoral trochlear cartilage status at second‐look arthroscopy. International Cartilage Repair Society (ICRS) grades 0–2 were defined as nearly normal and ICRS Grades 3–4 as abnormal for the purpose of this study. The primary outcomes were the Knee Injury and Osteoarthritis Outcome Score (KOOS) and Lysholm score at 2 years. Overlap weighting based on propensity score was used to adjust for confounders. Results: Of 331 patients, 229 were classified as nearly normal and 102 as abnormal. The abnormal group was older (67.15 ± 8.27 vs. 64.63 ± 9.74 years; p < 0.05) and showed persistently lower KOOS Symptoms at 12 and 24 months. In patients ≥65 years, adjusted 24‑month differences favoured the nearly normal group for KOOS Symptoms (−6.83; 95% confidence interval [CI]−12.48 to −1.19). In younger patients, early KOOS symptom deficits resolved by 24 months. Conclusions: Trochlear cartilage degeneration observed at second‐look arthroscopy after AKO is associated with poorer 2‐year outcomes, particularly in older patients. These findings suggest that a favourable trochlear cartilage status at second‐look is a meaningful prognostic indicator. Monitoring postoperative cartilage status—especially improvement or stability—may aid in identifying patients likely to achieve better recovery and inform age‐specific treatment strategies. Level of Evidence: Level III.

  • Open Access

    Accuracy Verification of Four-Dimensional CT Analysis of Knee Joint Movements: A Pilot Study Using a Knee Joint Model and Motion-Capture System

    by Takuya Adachi, Yuki Kato, Dai Kiyotomo, Katsushige Kawamukai, Shuzo Takazawa, Takahiro Suzuki, Youichi Machida

    The Ethics Statement and Conflict of Interest Disclosures section has been updated to disclose the following: Financial relationships: Dai Kiyotomo declare(s) employment from Teijin Nakashima Co., Ltd. This study was conducted as a collaborative research project with Teijin Nakashima Co., Ltd. The company’s research-use, non-commercial navigation software (N-view) was utilized. Dr. Kiyotomo prepared the knee joint model and performed the 3D-CT model reconstruction; data analysis was conducted by Drs. Yuki Kato (corresponding author) and Adachi. Teijin Nakashima Co., Ltd. had no role in the study design, decision to publish, or manuscript preparation.

  • Open Access

    Novel Use of Inverted V-shaped High Tibial Osteotomy in Treating Valgus Knee via Double-Level Osteotomy: A Clinical Case Report

    by Shuzo Takazawa, Yuki Kato, Ken Ichikawa

    Valgus knee deformity presents a surgical challenge when severe, especially with a hip-knee-ankle (HKA) angle exceeding 10°. While double-level osteotomy (DLO) is often used to correct complex deformities, the application of inverted V-shaped high tibial osteotomy (iVHTO) in valgus knees is rare. We present the case of a 70-year-old man with lateral compartment osteoarthritis and HKA of −18°, treated with DLO combining medial closing wedge distal femoral osteotomy and iVHTO. A correction of 10° at the femur and 12° at the tibia was achieved, with final alignment aimed at a mechanical axis of 45%. At the one-year follow-up, radiographic parameters showed maintained correction and bone union, with improved Knee Injury and Osteoarthritis Outcome Score. This case suggests that iVHTO, although typically used in varus knees, can be safely and effectively applied in valgus deformity as part of a DLO strategy.

  • Open Access

    Comparative study on clinical outcomes in autologous chondrocyte implantation using three-dimensional cultured JACC® with collagen versus periosteum coverings

    by Yuki Kato, Shin Yamada, Shuzo Takazawa, Soichi Hattori, Takuya Okada, Hiroshi Ohuchi

    This study investigates the efficacy of a collagen membrane as a substitute for autologous periosteum in atelocollagen-assisted autologous chondrocyte implantation (ACI) using J-TEC autologous cultured cartilage (JACC®). Sixty-nine patients with knee joint chondral defects underwent ACI using JACC®—34 with periosteum-covered ACI (P-ACIs) and 35 with collagen-covered ACI (C-ACIs). Clinical outcomes were compared through patient-reported measures, International Cartilage Repair Society (ICRS) Cartilage Repair Assessment (CRA) scores at second-look arthroscopy one year postoperatively, and adverse event incidence. Postoperative subjective scores significantly improved up to two years, with no significant differences between P-ACI and C-ACI groups. However, C-ACI exhibited a lower adverse event rate (p = 0.034) and significantly higher ICRS CRA scores (p = 0.0001). Notably, C-ACI outperformed P-ACI in both femoral condyle and trochlea assessments (p = 0.0157 and 0.0005, respectively). While clinical outcomes were comparable, the use of a collagen membrane demonstrated superiority in ICRS CRA during second-look arthroscopy and adverse event occurrence.


  • Open Access

    Accuracy Verification of Four-Dimensional CT Analysis of Knee Joint Movements: A Pilot Study Using a Knee Joint Model and Motion-Capture System

    by Takuya Adachi, Yuki Kato, Dai Kiyotomo, Katsushige Kawamukai, Shuzo Takazawa, Takahiro Suzuki, Youichi Machida

    Objective This study aimed to use the optical motion-capture method to verify the accuracy of four-dimensional computed tomography (4D-CT) analysis of knee joint movement. Methods One static CT and three 4D-CT examinations of the knee joint model were obtained. The knee joint model was passively moved in the CT gantry during 4D-CT acquisitions. 4D-CT and static CT examinations were matched to perform 3D-3D registration. An optical-motion capture system recorded the position-posture of the knee joint model simultaneously with the 4D-CT acquisitions. Reference axes (X, Y, and Z directions) were defined based on static CT and applied to 4D-CT and the optical-motion capture system. Using the position-posture of the motion capture system as a reference standard, the position-posture measurements using 4D-CT were compared to these values, and the accuracy of the 4D-CT analysis of knee joint movements was quantitatively assessed. Results The position-posture measurements obtained from 4D-CT showed a similar tendency to those obtained from the motion-capture system. In the femorotibial joint, the difference in the spatial orientation between the two measurements was 0.7 mm in the X direction, 0.9 mm in the Y direction, and 2.8 mm in the Z direction. The difference in angle was 1.9° in the varus/valgus direction, 1.1° in the internal/external rotation, and 1.8° in extension/flexion. In the patellofemoral joint, the difference between the two measurements was 0.9 mm in the X direction, 1.3 mm in the Y direction, and 1.2 mm in the Z direction. The difference in angle was 0.9° for varus/valgus, 1.1° for internal/external rotation, and 1.3° for extension/flexion. Conclusions 4D-CT with 3D-3D registration could record the position-posture of knee joint movements with an error of less than 3 mm and less than 2° when compared with the highly accurate optical-motion capture system. Knee joint movement analysis using 4D-CT with 3D-3D registration showed excellent accuracy for in vivo applications.