Marinês Dalla Valle Martino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marinês Dalla Valle Martino has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Paula Célia Mariko Koga
Laboratório Clínico, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
3 shared publications - André Mario Doi
Laboratório Clínico, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
2 shared publications - Adagmar Andriolo
Universidade Federal de São Paulo, Brazil; Sociedade Brasileira de Patologia Clínica e Medicina Laboratorial, Brazil
1 shared publication - Alexandra Do Rosário Toniolo
Hospital Israelita Albert Einstein, São Paulo, Brazil
1 shared publication - Alexandre Gimenes Marques
Hospital Israelita Albert Einstein, São Paulo, SP, Brasil
1 shared publication - Alexandre Rodrigues Marra
Hospital Israelita Albert Einstein
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 24, eAO1627
COVID-19 pandemic-driven evolution of Klebsiella pneumoniae : rising resistance, genetic diversity, and virulence in a Brazilian tertiary hospital
Coronavirus disease 2019 (COVID-19) caused increased intensive care unit admissions, invasive procedures, and antimicrobial use, potentially worsening bacterial infections and multidrug resistance. Retrospective studies have found that Klebsiella pneumoniae co-infections in COVID-19 patients were significant and possibly linked to mechanical ventilation and central catheter placement. In the present study, we assessed the genetic diversity and antimicrobial resistance of K. pneumoniae isolates collected before and during the pandemic to evaluate the effect of the pandemic on these factors. Antimicrobial resistance profiling, whole-genome sequencing, and phylogenetic analyses were used to examine resistance patterns, genetic diversity, and mobile genetic elements. From January 2018 to January 2021, 263 K. pneumoniae isolates were identified from infection sites. Carbapenem-resistant isolates increased from 32.5% in 2019 to 60.3% in 2020, remaining stable until January 2021. Nevertheless, healthcare-associated infections did not increase significantly, highlighting the effectiveness of infection control programs. Whole-genome sequencing showed that 54% of carbapenem-resistant isolates carried plasmids resembling pKPC_FCF3SP (IncN) and pKpQIL-like (IncFII) plasmids; however, the number of pKpQIL-like plasmid carriers declined during the pandemic likely due to patient transfer carrying isolates with distinct mobilome. Simultaneously, the number of plasmid-negative isolates increased by 25%. Carbapenem-resistant isolates showed multidrug resistance, particularly to cephalosporins and fluoroquinolones; however, aminoglycosides remained effective. Genetic analysis identified ten aminoglycoside resistance genes, with aac(6')-Ib-D181Y associated with improved substrate recognition, being the most prevalent. Virulence factors included four integrative conjugative elements, with the integrative conjugative element K. pneumoniae ICEKp4 found only in pandemic period isolates. The O4 and O2 antigens predominated, whereas O3b appeared exclusively during the pandemic. The COVID-19 pandemic has contributed to a rise in carbapenem-resistant K. pneumoniae , underscoring the need for ongoing surveillance. Molecular shifts reflect the adaptation of the pathogen to evolving clinical settings.
- 1 April 2026
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 24, eAO1627
Open AccessCOVID-19 pandemic-driven evolution of Klebsiella pneumoniae : rising resistance, genetic diversity, and virulence in a Brazilian tertiary hospital
Coronavirus disease 2019 (COVID-19) caused increased intensive care unit admissions, invasive procedures, and antimicrobial use, potentially worsening bacterial infections and multidrug resistance. Retrospective studies have found that Klebsiella pneumoniae co-infections in COVID-19 patients were significant and possibly linked to mechanical ventilation and central catheter placement. In the present study, we assessed the genetic diversity and antimicrobial resistance of K. pneumoniae isolates collected before and during the pandemic to evaluate the effect of the pandemic on these factors. Antimicrobial resistance profiling, whole-genome sequencing, and phylogenetic analyses were used to examine resistance patterns, genetic diversity, and mobile genetic elements. From January 2018 to January 2021, 263 K. pneumoniae isolates were identified from infection sites. Carbapenem-resistant isolates increased from 32.5% in 2019 to 60.3% in 2020, remaining stable until January 2021. Nevertheless, healthcare-associated infections did not increase significantly, highlighting the effectiveness of infection control programs. Whole-genome sequencing showed that 54% of carbapenem-resistant isolates carried plasmids resembling pKPC_FCF3SP (IncN) and pKpQIL-like (IncFII) plasmids; however, the number of pKpQIL-like plasmid carriers declined during the pandemic likely due to patient transfer carrying isolates with distinct mobilome. Simultaneously, the number of plasmid-negative isolates increased by 25%. Carbapenem-resistant isolates showed multidrug resistance, particularly to cephalosporins and fluoroquinolones; however, aminoglycosides remained effective. Genetic analysis identified ten aminoglycoside resistance genes, with aac(6')-Ib-D181Y associated with improved substrate recognition, being the most prevalent. Virulence factors included four integrative conjugative elements, with the integrative conjugative element K. pneumoniae ICEKp4 found only in pandemic period isolates. The O4 and O2 antigens predominated, whereas O3b appeared exclusively during the pandemic. The COVID-19 pandemic has contributed to a rise in carbapenem-resistant K. pneumoniae , underscoring the need for ongoing surveillance. Molecular shifts reflect the adaptation of the pathogen to evolving clinical settings.
- Open Access
- 25 January 2024
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 82 (01) , 001-008
Evaluation of pathogen from the FilmArray meningitis/encephalitis panel and recommendations on atypical findings
Background Infectious meningoencephalitis is a potentially fatal clinical condition that causes inflammation of the central nervous system secondary to the installation of different microorganisms. The FilmArray meningitis/encephalitis panel allows the simultaneous detection of 14 pathogens with results in about one hour. Objective This study is based on retrospectively evaluating the implementation of the FilmArray meningitis/encephalitis panel in a hospital environment, highlighting the general results and, especially, analyzing the consistency of the test results against the clinical and laboratory conditions of the patients. Methods Data were collected through the results reported by the BioFire FilmArray system software from the meningitis/encephalitis panel. The correlated laboratory tests used in our analysis, when available, included biochemical, cytological, direct and indirect microbiological tests. Results In the analyzed period, there were 496 samples with released results. Of the total of 496 samples analyzed, 88 (17.75%) were considered positive, and 90 pathogens were detected, and in 2 of these (2.27%) there was co-detection of pathogens. Viruses were the agents most frequently found within the total number of pathogens detected. Of the 496 proven samples, 20 (4.03%) were repeated, 5 of which were repeated due to invalid results, 6 due to the detection of multiple pathogens and 9 due to disagreement between the panel results and the other laboratory tests and/or divergence of the clinical-epidemiological picture. Of these 20 repeated samples, only 4 of them (20%) maintained the original result after repeating the test, with 16 (80%) being non-reproducible. The main factor related to the disagreement of these 16 samples during retesting was the detection of bacterial agents without any relationship with other laboratory tests or with the patients' clinical condition. Conclusion In our study, simply reproducing tests with atypical results from the FilmArray meningitis/encephalitis panel proved, in most cases, effective and sufficient for interpreting these results.
- 25 January 2024
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 82 (01) , 001-008
Open AccessEvaluation of pathogen from the FilmArray meningitis/encephalitis panel and recommendations on atypical findings
Background Infectious meningoencephalitis is a potentially fatal clinical condition that causes inflammation of the central nervous system secondary to the installation of different microorganisms. The FilmArray meningitis/encephalitis panel allows the simultaneous detection of 14 pathogens with results in about one hour. Objective This study is based on retrospectively evaluating the implementation of the FilmArray meningitis/encephalitis panel in a hospital environment, highlighting the general results and, especially, analyzing the consistency of the test results against the clinical and laboratory conditions of the patients. Methods Data were collected through the results reported by the BioFire FilmArray system software from the meningitis/encephalitis panel. The correlated laboratory tests used in our analysis, when available, included biochemical, cytological, direct and indirect microbiological tests. Results In the analyzed period, there were 496 samples with released results. Of the total of 496 samples analyzed, 88 (17.75%) were considered positive, and 90 pathogens were detected, and in 2 of these (2.27%) there was co-detection of pathogens. Viruses were the agents most frequently found within the total number of pathogens detected. Of the 496 proven samples, 20 (4.03%) were repeated, 5 of which were repeated due to invalid results, 6 due to the detection of multiple pathogens and 9 due to disagreement between the panel results and the other laboratory tests and/or divergence of the clinical-epidemiological picture. Of these 20 repeated samples, only 4 of them (20%) maintained the original result after repeating the test, with 16 (80%) being non-reproducible. The main factor related to the disagreement of these 16 samples during retesting was the detection of bacterial agents without any relationship with other laboratory tests or with the patients' clinical condition. Conclusion In our study, simply reproducing tests with atypical results from the FilmArray meningitis/encephalitis panel proved, in most cases, effective and sufficient for interpreting these results.
- Open Access
- 11 August 2023
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 10 (9) , ofad433
Diagnostic Stewardship: A Systematic Review and Meta-analysis of Blood Collection Diversion Devices Used to Reduce Blood Culture Contamination and Improve the Accuracy of Diagnosis in Clinical Settings
Blood culture contamination may lead to misdiagnosis, overutilization of antibiotics, and prolonged length of stay. Blood specimen diversion devices can reduce contamination rates during blood culture collection procedures. We performed a systematic literature review and meta-analysis evaluating the influence of blood specimen diversion devices in blood culture contamination rates. We searched Medline, Cumulative Index to Nursing and Allied Health Literature, Embase, Cochrane, Scopus, and Web of Science, from database inception to 1 March 2023, for studies evaluating the impact of a diversion device on blood culture contamination. Blood culture contamination was a positive blood culture with microorganisms not representative of true bacteremia, but rather introduced during collection or processing the blood sample. Random-effects models were used to obtain pooled mean differences, and heterogeneity was assessed using the I2 test. Of 1768 screened studies, 12 met inclusion criteria for this systematic literature review. Of them, 9 studies were included in the meta-analysis. Studies were substantially heterogeneous, but stratified analyses considering only high-quality studies revealed that venipuncture using a diversion device was associated with a significant reduction in blood culture contamination in comparison to the standard procedure of collection (pooled odds ratio [OR], 0.26 [95% confidence interval {CI}, .13–.54]; I2 = 19%). Furthermore, the stratified analysis showed that the adoption of a diversion device did not reduce the detection of true infection (pooled OR, 0.85 [95% CI, .65–1.11]; I2 = 0%). Blood culture diversion devices was associated with decreased contamination rates and could improve quality of care, reduce costs, and avoid unnecessary antibiotic use.
- 11 August 2023
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 10 (9) , ofad433
Open AccessDiagnostic Stewardship: A Systematic Review and Meta-analysis of Blood Collection Diversion Devices Used to Reduce Blood Culture Contamination and Improve the Accuracy of Diagnosis in Clinical Settings
Blood culture contamination may lead to misdiagnosis, overutilization of antibiotics, and prolonged length of stay. Blood specimen diversion devices can reduce contamination rates during blood culture collection procedures. We performed a systematic literature review and meta-analysis evaluating the influence of blood specimen diversion devices in blood culture contamination rates. We searched Medline, Cumulative Index to Nursing and Allied Health Literature, Embase, Cochrane, Scopus, and Web of Science, from database inception to 1 March 2023, for studies evaluating the impact of a diversion device on blood culture contamination. Blood culture contamination was a positive blood culture with microorganisms not representative of true bacteremia, but rather introduced during collection or processing the blood sample. Random-effects models were used to obtain pooled mean differences, and heterogeneity was assessed using the I2 test. Of 1768 screened studies, 12 met inclusion criteria for this systematic literature review. Of them, 9 studies were included in the meta-analysis. Studies were substantially heterogeneous, but stratified analyses considering only high-quality studies revealed that venipuncture using a diversion device was associated with a significant reduction in blood culture contamination in comparison to the standard procedure of collection (pooled odds ratio [OR], 0.26 [95% confidence interval {CI}, .13–.54]; I2 = 19%). Furthermore, the stratified analysis showed that the adoption of a diversion device did not reduce the detection of true infection (pooled OR, 0.85 [95% CI, .65–1.11]; I2 = 0%). Blood culture diversion devices was associated with decreased contamination rates and could improve quality of care, reduce costs, and avoid unnecessary antibiotic use.
- Open Access
- 30 April 2020
- Published by Elsevier in The Brazilian Journal of Infectious Diseases
- Vol. 24 (2) , 110-119
Joint report of SBI (Brazilian Society of Infectious Diseases), FEBRASGO (Brazilian Federation of Gynecology and Obstetrics Associations), SBU (Brazilian Society of Urology) and SBPC/ML (Brazilian Society of Clinical Pathology/Laboratory Medicine): recommendations for the clinical management of lower urinary tract infections in pregnant and non-pregnant women
- 30 April 2020
- Published by Elsevier in The Brazilian Journal of Infectious Diseases
- Vol. 24 (2) , 110-119
Open AccessJoint report of SBI (Brazilian Society of Infectious Diseases), FEBRASGO (Brazilian Federation of Gynecology and Obstetrics Associations), SBU (Brazilian Society of Urology) and SBPC/ML (Brazilian Society of Clinical Pathology/Laboratory Medicine): recommendations for the clinical management of lower urinary tract infections in pregnant and non-pregnant women
- Open Access
- 12 December 2018
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 17 (1) , eAI4441
Desafio no diagnóstico de estrongiloidíase pulmonar
- 12 December 2018
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 17 (1) , eAI4441
Open AccessDesafio no diagnóstico de estrongiloidíase pulmonar
- Open Access
- 1 August 2011
- Published by FapUNIFESP (SciELO) in Jornal Brasileiro de Patologia e Medicina Laboratorial
- Vol. 47 (4) , 427-430
Estudo comparativo de detecção de metapneumovírus humano pelos métodos de PCR e imunofluorescência direta
INTRODUÇÃO: O metapneumovírus humano (MPVh) causa infecções respiratórias em crianças, adultos e idosos imunodeprimidos. O diagnóstico é realizado por imunofluorescência (IF) ou biologia molecular. OBJETIVO: Detectar o MPVh em amostras clínicas pelos métodos de reação em cadeia da polimerase (PCR) e imunofluorescência direta (IFD). RESULTADOS: Das 202 amostras, a positividade foi de 2% e 4% para IFD e RT-PCR, respectivamente. Sensibilidade e especificidade da IFD foram de 50% e 100%, respectivamente, considerando o PCR com transcrição reversa (RT-PCR) como padrão-ouro. CONCLUSÃO: O estudo indica a RT-PCR como o melhor método para a identificação de MPVh em amostras clínicas respiratórias e mostra a importância da padronização do teste para inclusão na rotina laboratorial. INTRODUCTION: Human metapneumovirus (HMPV) is responsible for respiratory infections in children and immunocompromised adults and elders. It is commonly diagnosed by immunofluorescence or molecular biology. OBJECTIVE: To detect HMPV in clinical samples by polymerase chain reaction (PCR) and direct imunofluorescence (DIF) methods. RESULTS: Two percent of 202 samples were positive for DIF and 4% of them for reverse transcriptase PCR (RT-PCR), respectively. Considering RT-PCR as gold standard, DIF sensitivity and specificity were 50% and 100%, respectively. CONCLUSION: Not only does the study show that RT-PCR is the best method for HMPV detection in clinical respiratory samples but it also substantiates the importance of test standardization in laboratory routine
- 1 August 2011
- Published by FapUNIFESP (SciELO) in Jornal Brasileiro de Patologia e Medicina Laboratorial
- Vol. 47 (4) , 427-430
Open AccessEstudo comparativo de detecção de metapneumovírus humano pelos métodos de PCR e imunofluorescência direta
INTRODUÇÃO: O metapneumovírus humano (MPVh) causa infecções respiratórias em crianças, adultos e idosos imunodeprimidos. O diagnóstico é realizado por imunofluorescência (IF) ou biologia molecular. OBJETIVO: Detectar o MPVh em amostras clínicas pelos métodos de reação em cadeia da polimerase (PCR) e imunofluorescência direta (IFD). RESULTADOS: Das 202 amostras, a positividade foi de 2% e 4% para IFD e RT-PCR, respectivamente. Sensibilidade e especificidade da IFD foram de 50% e 100%, respectivamente, considerando o PCR com transcrição reversa (RT-PCR) como padrão-ouro. CONCLUSÃO: O estudo indica a RT-PCR como o melhor método para a identificação de MPVh em amostras clínicas respiratórias e mostra a importância da padronização do teste para inclusão na rotina laboratorial. INTRODUCTION: Human metapneumovirus (HMPV) is responsible for respiratory infections in children and immunocompromised adults and elders. It is commonly diagnosed by immunofluorescence or molecular biology. OBJECTIVE: To detect HMPV in clinical samples by polymerase chain reaction (PCR) and direct imunofluorescence (DIF) methods. RESULTS: Two percent of 202 samples were positive for DIF and 4% of them for reverse transcriptase PCR (RT-PCR), respectively. Considering RT-PCR as gold standard, DIF sensitivity and specificity were 50% and 100%, respectively. CONCLUSION: Not only does the study show that RT-PCR is the best method for HMPV detection in clinical respiratory samples but it also substantiates the importance of test standardization in laboratory routine