Eduardo Messias Hirano Padrao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eduardo Messias Hirano Padrao has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Isabela Reis Marques
Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
5 shared publications - Elias Baedorf Kassis
Dr. Baedorf-Kassis is affiliated with Division of Pulmonary, Critical Care & Sleep Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
3 shared publications - Izabela Pera Calvi
Division of Medicine, Immanuel Kant Baltic Federal University, Kaliningrad, Russia
3 shared publications - Sara Almeida Cruz
Immanuel Kant Baltic Federal University, Russia
3 shared publications - Alper Gulluoglu
Harvard Medical School
2 shared publications Ashwin Mahesh
Department of Medicine, University of Connecticut, Farmington, CT, USA
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 141 (2) , 653-660
The association of elevated pleural pressures with airway collapse during inspiration and expiration in mechanically ventilated patients
In our hypothesis-generating study, elevated pleural pressures and auto-PEEP correlate with the degree of AOP (measured by slow-flow pressure-volume curves). Elevated pleural pressures also correlated with the presence of EFL. There is an association between the presence of AOP and EFL when measured by the Rex method. In patients with EFL, resolution occurred in most patients with 80% of the measured auto-PEEP at zero PEEP.
- 1 September 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 141 (2) , 653-660
Open AccessThe association of elevated pleural pressures with airway collapse during inspiration and expiration in mechanically ventilated patients
In our hypothesis-generating study, elevated pleural pressures and auto-PEEP correlate with the degree of AOP (measured by slow-flow pressure-volume curves). Elevated pleural pressures also correlated with the presence of EFL. There is an association between the presence of AOP and EFL when measured by the Rex method. In patients with EFL, resolution occurred in most patients with 80% of the measured auto-PEEP at zero PEEP.
- 1 May 2026
- Published by Springer Nature in Journal of Medical Systems
- Vol. 50 (1) , 69
Automated data extraction from electronic medical records for pragmatic clinical trials
Data collection in randomized trials is expensive and labor intensive. With the rise in ongoing pragmatic trials, the use of electronic medical records (EMR) as a source of data has increased. Although potentially faster and cheaper, EMR use can lead to errors. Therefore, to ensure accurate data collection and to avoid systematic errors we performed a study comparing automated data extraction (ADE) with manual data extraction (MDE). We performed a retrospective cohort study to compare the accuracy of ADE using Structured Query Language with MDE by blinded physicians from our EMR. We tested the interrater agreement and intraclass correlation coefficient of clinical baseline data and outcomes of a random sample of 30 patients admitted to the ICU, on mechanical ventilation, requiring opioids for analgosedation for an upcoming pragmatic clinical trial. Key data compared included, but not limited to, patient’s demographics, laboratory and vital signs, daily morphine milligram equivalent (MME), days alive and free of mechanical ventilation, days alive and free of hospitalization, days alive and free of ICU, days alive and free of vasopressors, and death. Among 238 patients screened over 1-month period, 72 fulfilled inclusion criteria and 30 were randomly selected to be included in the evaluation. We blindly collected 1320 baseline data, 2160 categorical outcomes and 705 continuous outcomes for a total of 4185 data points. The intraclass correlation coefficient and the Cohen’s Kappa were perfect or almost perfect for all data, including outcomes such as daily MME, days alive and free of mechanical ventilation, days alive and free of ICU and days alive and free of hospital with p < 0.001. Among all rechecked data, the ADE was correct in 53 (77.9%) of cases, while MDE in 15 (22.1%). The inaccurate data collected by ADE accounted for 0.36% of the total data-points. The performance of ADE had almost perfect agreement for all outcomes and when rechecking for disagreements, it was more accurate than MDE.
- 1 May 2026
- Published by Springer Nature in Journal of Medical Systems
- Vol. 50 (1) , 69
Automated data extraction from electronic medical records for pragmatic clinical trials
Data collection in randomized trials is expensive and labor intensive. With the rise in ongoing pragmatic trials, the use of electronic medical records (EMR) as a source of data has increased. Although potentially faster and cheaper, EMR use can lead to errors. Therefore, to ensure accurate data collection and to avoid systematic errors we performed a study comparing automated data extraction (ADE) with manual data extraction (MDE). We performed a retrospective cohort study to compare the accuracy of ADE using Structured Query Language with MDE by blinded physicians from our EMR. We tested the interrater agreement and intraclass correlation coefficient of clinical baseline data and outcomes of a random sample of 30 patients admitted to the ICU, on mechanical ventilation, requiring opioids for analgosedation for an upcoming pragmatic clinical trial. Key data compared included, but not limited to, patient’s demographics, laboratory and vital signs, daily morphine milligram equivalent (MME), days alive and free of mechanical ventilation, days alive and free of hospitalization, days alive and free of ICU, days alive and free of vasopressors, and death. Among 238 patients screened over 1-month period, 72 fulfilled inclusion criteria and 30 were randomly selected to be included in the evaluation. We blindly collected 1320 baseline data, 2160 categorical outcomes and 705 continuous outcomes for a total of 4185 data points. The intraclass correlation coefficient and the Cohen’s Kappa were perfect or almost perfect for all data, including outcomes such as daily MME, days alive and free of mechanical ventilation, days alive and free of ICU and days alive and free of hospital with p < 0.001. Among all rechecked data, the ADE was correct in 53 (77.9%) of cases, while MDE in 15 (22.1%). The inaccurate data collected by ADE accounted for 0.36% of the total data-points. The performance of ADE had almost perfect agreement for all outcomes and when rechecking for disagreements, it was more accurate than MDE.
- Open Access
- 1 March 2026
- Vol. 7 (1) , 86-88
A Bedside Assessment of Auto-Positive End-Expiratory Pressure: Identifying Expiratory Flow Limitation.
- 1 March 2026
- Vol. 7 (1) , 86-88
Open AccessA Bedside Assessment of Auto-Positive End-Expiratory Pressure: Identifying Expiratory Flow Limitation.
- 14 August 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (11) , e2271-e2281
Lung Ultrasound Findings and Algorithms to Detect Pneumonia: A Systematic Review and Diagnostic Testing Meta-Analysis
OBJECTIVE: Lung ultrasound is increasingly used for diagnosing pneumonia due to its accessibility, low cost, and lack of radiation exposure. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of individual lung ultrasound findings and algorithms for pneumonia across various clinical settings compared with chest radiography and CT. DATA SOURCES: We systematically searched PubMed, Embase, and Cochrane databases. STUDY SELECTION AND DATA EXTRACTION: We searched for studies assessing the sensitivity and specificity of lung ultrasound findings and algorithms for pneumonia. Studies including adult patients with community-acquired, hospital-acquired, or ventilator-associated pneumonia (VAP) were eligible. Data on sensitivity, specificity, and likelihood ratios for ultrasonographic findings and algorithms were pooled using bivariate linear mixed models and Bayesian analyses. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. DATA SYNTHESIS: Twenty-six studies, totaling 3454 patients, were included. The Bed Lung Ultrasound in Emergency (BLUE) protocol demonstrated the highest sensitivity (0.88; 95% CI, 0.84–0.92) among all criteria studies, whereas dynamic air bronchograms had the highest specificity (0.96; 95% CI, 0.91–0.99). Focal B-lines had low sensitivity (0.24; 95% CI, 0.12–0.43) and high specificity (0.96; 95% CI, 0.86–0.99). Sensitivity analyses indicated reduced specificity for lung ultrasound in patients with VAP across all evaluated criteria. Bayesian analyses yielded consistent results across different prior assumptions. CONCLUSIONS: Lung ultrasound demonstrates good diagnostic performance for detecting community-acquired and hospital-acquired pneumonia. However, its utility in diagnosing VAP is limited, suggesting the need for complementary diagnostic tools in this patient group. This underscores the importance of lung ultrasound as a frontline diagnostic tool for pneumonia. To the best of our knowledge, this is the first meta-analysis to evaluate the specificity and sensitivity of each specific finding identified by lung ultrasound.
- 14 August 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (11) , e2271-e2281
Lung Ultrasound Findings and Algorithms to Detect Pneumonia: A Systematic Review and Diagnostic Testing Meta-Analysis
OBJECTIVE: Lung ultrasound is increasingly used for diagnosing pneumonia due to its accessibility, low cost, and lack of radiation exposure. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of individual lung ultrasound findings and algorithms for pneumonia across various clinical settings compared with chest radiography and CT. DATA SOURCES: We systematically searched PubMed, Embase, and Cochrane databases. STUDY SELECTION AND DATA EXTRACTION: We searched for studies assessing the sensitivity and specificity of lung ultrasound findings and algorithms for pneumonia. Studies including adult patients with community-acquired, hospital-acquired, or ventilator-associated pneumonia (VAP) were eligible. Data on sensitivity, specificity, and likelihood ratios for ultrasonographic findings and algorithms were pooled using bivariate linear mixed models and Bayesian analyses. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. DATA SYNTHESIS: Twenty-six studies, totaling 3454 patients, were included. The Bed Lung Ultrasound in Emergency (BLUE) protocol demonstrated the highest sensitivity (0.88; 95% CI, 0.84–0.92) among all criteria studies, whereas dynamic air bronchograms had the highest specificity (0.96; 95% CI, 0.91–0.99). Focal B-lines had low sensitivity (0.24; 95% CI, 0.12–0.43) and high specificity (0.96; 95% CI, 0.86–0.99). Sensitivity analyses indicated reduced specificity for lung ultrasound in patients with VAP across all evaluated criteria. Bayesian analyses yielded consistent results across different prior assumptions. CONCLUSIONS: Lung ultrasound demonstrates good diagnostic performance for detecting community-acquired and hospital-acquired pneumonia. However, its utility in diagnosing VAP is limited, suggesting the need for complementary diagnostic tools in this patient group. This underscores the importance of lung ultrasound as a frontline diagnostic tool for pneumonia. To the best of our knowledge, this is the first meta-analysis to evaluate the specificity and sensitivity of each specific finding identified by lung ultrasound.
- Open Access
- 21 May 2025
- Published by Associação de Medicina Intensiva Brasileira in Critical Care Science
- Vol. 37, e20250228
Cardiopulmonary resuscitation in Brazilian medical television shows: a descriptive and quality assessment study
Objective: To assess the accuracy of Brazilian television depictions of cardiopulmonary arrest, their management, and outcomes and to compare the observed outcomes with prior data from observational studies. Methods: Investigators screened episodes, identified cardiac arrest scenes, collected relevant information, and assessed outcomes. Cardiac arrest scenes were then analyzed using the American Heart Association guidelines. […] ABSTRACT Objective: To assess the accuracy of Brazilian television depictions of cardiopulmonary arrest, their management, and outcomes and to compare the observed outcomes with prior data from observational studies. Methods: Investigators screened episodes, identified cardiac arrest scenes, collected relevant information, and assessed outcomes. Cardiac arrest scenes were then analyzed using the American Heart Association guidelines. […]
- 21 May 2025
- Published by Associação de Medicina Intensiva Brasileira in Critical Care Science
- Vol. 37, e20250228
Open AccessCardiopulmonary resuscitation in Brazilian medical television shows: a descriptive and quality assessment study
Objective: To assess the accuracy of Brazilian television depictions of cardiopulmonary arrest, their management, and outcomes and to compare the observed outcomes with prior data from observational studies. Methods: Investigators screened episodes, identified cardiac arrest scenes, collected relevant information, and assessed outcomes. Cardiac arrest scenes were then analyzed using the American Heart Association guidelines. […] ABSTRACT Objective: To assess the accuracy of Brazilian television depictions of cardiopulmonary arrest, their management, and outcomes and to compare the observed outcomes with prior data from observational studies. Methods: Investigators screened episodes, identified cardiac arrest scenes, collected relevant information, and assessed outcomes. Cardiac arrest scenes were then analyzed using the American Heart Association guidelines. […]
- Open Access
- 28 September 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-18
Glucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials
Background: Glycaemic control of Type 1 Diabetes Mellitus (T1DM) remains a challenge due to hypoglycaemic episodes and the burden of insulin self-management. Advancements have been made with the development of automated insulin delivery (AID) devices, yet, previous reviews have only assessed the use of AID over days or weeks, and potential benefits with longer time of AID use in this population remain unclear. Methods: We performed a systematic review and meta-analysis of randomised controlled trials comparing AID (hybrid and fully closed-loop systems) to usual care (sensor augmented pumps, multiple daily insulin injections, continuous glucose monitoring and predictive low-glucose suspend) for adults and children with T1DM with a minimum duration of 3 months. We searched PubMed, Embase, Cochrane Central, and Clinicaltrials.gov for studies published up until April 4, 2023. Main outcomes included time in range 70–180 mg/dL as the primary outcome, and change in HbA1c (%, mmol/mol), glucose variability, and psychosocial impact (diabetes distress, treatment satisfaction and fear of hypoglycaemia) as secondary outcomes. Adverse events included diabetic ketoacidosis (DKA) and severe hypoglycaemia. Statistical analyses were conducted using mean differences and odds ratios. Sensitivity analyses were performed according to age, study duration and type of AID device. The protocol was registered in PROSPERO, CRD42022366710. Results: We identified 25 comparisons from 22 studies (six crossover and 16 parallel designs) including a total of 2376 participants (721 in adult studies, 621 in paediatric studies, and 1034 in combined studies) which were eligible for analysis. Use of AID devices ranged from 12 to 96 weeks. Patients using AID had 10.87% higher time in range [95% CI 9.38 to 12.37; p < 0.0001, I2 = 87%) and 0.37% (4.77 mmol/mol) lower HbA1c (95% CI − 0.49% (− 6.39 mmol/mol) to – 0.26 (− 3.14 mmol/mol); p < 0·0001, I2 = 77%]. AID systems decreased night hypoglycaemia, time in hypoglycaemia and hyperglycaemia and improved patient distress, with no increase in the risk of DKA or severe hypoglycaemia. No difference was found regarding treatment satisfaction or fear of hypoglycaemia. Among children, there was no difference in glucose variability or time spent in hypoglycaemia between the use of AID systems or usual care. In sensitivity analyses, results remained consistent with the overall analysis favouring AID. Conclusion: The use of AID systems over 12 weeks, regardless of technical or clinical differences, improved glycaemic outcomes and diabetes distress without increasing the risk of adverse events in adults and children with T1DM.
- 28 September 2023
- Published by Springer Nature in Diabetology & Metabolic Syndrome
- Vol. 15 (1) , 1-18
Open AccessGlucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials
Background: Glycaemic control of Type 1 Diabetes Mellitus (T1DM) remains a challenge due to hypoglycaemic episodes and the burden of insulin self-management. Advancements have been made with the development of automated insulin delivery (AID) devices, yet, previous reviews have only assessed the use of AID over days or weeks, and potential benefits with longer time of AID use in this population remain unclear. Methods: We performed a systematic review and meta-analysis of randomised controlled trials comparing AID (hybrid and fully closed-loop systems) to usual care (sensor augmented pumps, multiple daily insulin injections, continuous glucose monitoring and predictive low-glucose suspend) for adults and children with T1DM with a minimum duration of 3 months. We searched PubMed, Embase, Cochrane Central, and Clinicaltrials.gov for studies published up until April 4, 2023. Main outcomes included time in range 70–180 mg/dL as the primary outcome, and change in HbA1c (%, mmol/mol), glucose variability, and psychosocial impact (diabetes distress, treatment satisfaction and fear of hypoglycaemia) as secondary outcomes. Adverse events included diabetic ketoacidosis (DKA) and severe hypoglycaemia. Statistical analyses were conducted using mean differences and odds ratios. Sensitivity analyses were performed according to age, study duration and type of AID device. The protocol was registered in PROSPERO, CRD42022366710. Results: We identified 25 comparisons from 22 studies (six crossover and 16 parallel designs) including a total of 2376 participants (721 in adult studies, 621 in paediatric studies, and 1034 in combined studies) which were eligible for analysis. Use of AID devices ranged from 12 to 96 weeks. Patients using AID had 10.87% higher time in range [95% CI 9.38 to 12.37; p < 0.0001, I2 = 87%) and 0.37% (4.77 mmol/mol) lower HbA1c (95% CI − 0.49% (− 6.39 mmol/mol) to – 0.26 (− 3.14 mmol/mol); p < 0·0001, I2 = 77%]. AID systems decreased night hypoglycaemia, time in hypoglycaemia and hyperglycaemia and improved patient distress, with no increase in the risk of DKA or severe hypoglycaemia. No difference was found regarding treatment satisfaction or fear of hypoglycaemia. Among children, there was no difference in glucose variability or time spent in hypoglycaemia between the use of AID systems or usual care. In sensitivity analyses, results remained consistent with the overall analysis favouring AID. Conclusion: The use of AID systems over 12 weeks, regardless of technical or clinical differences, improved glycaemic outcomes and diabetes distress without increasing the risk of adverse events in adults and children with T1DM.
- 18 September 2023
- Published by Wiley in Pediatric Dermatology
- Vol. 40 (6) , 1060-1063
Safety and efficacy of topical nitric oxide‐releasing berdazimer gel for molluscum contagiosum clearance: A systematic review and meta‐analysis of randomized controlled trials
Molluscum contagiosum (MC) is a contagious infection that, although benign, can become an aesthetic burden and lead to other opportunistic infections, secondary dermatitis, and self‐isolation. Currently, several treatment options are available for MC, including the newly investigated nitric oxide‐releasing berdazimer gel, leading this review to evaluate randomized controlled trials (RCT) comparing berdazimer gel with a vehicle for treating MC. The meta‐analysis included three reports and four RCT involving 1854 patients, with 1106 (59.6%) randomized to receive berdazimer. Our findings suggest that berdazimer is effective in the management of MC lesions, but the increased clearance of lesions and reduction of scarring must be weighed against the potential for topical adverse effects, particularly when considering the use of this therapy in pediatric patients.
- 18 September 2023
- Published by Wiley in Pediatric Dermatology
- Vol. 40 (6) , 1060-1063
Safety and efficacy of topical nitric oxide‐releasing berdazimer gel for molluscum contagiosum clearance: A systematic review and meta‐analysis of randomized controlled trials
Molluscum contagiosum (MC) is a contagious infection that, although benign, can become an aesthetic burden and lead to other opportunistic infections, secondary dermatitis, and self‐isolation. Currently, several treatment options are available for MC, including the newly investigated nitric oxide‐releasing berdazimer gel, leading this review to evaluate randomized controlled trials (RCT) comparing berdazimer gel with a vehicle for treating MC. The meta‐analysis included three reports and four RCT involving 1854 patients, with 1106 (59.6%) randomized to receive berdazimer. Our findings suggest that berdazimer is effective in the management of MC lesions, but the increased clearance of lesions and reduction of scarring must be weighed against the potential for topical adverse effects, particularly when considering the use of this therapy in pediatric patients.
- 17 July 2023
- Published by Springer Nature in International Journal of Obesity
- Vol. 47 (10) , 883-892
Efficacy and safety of the dual GIP and GLP-1 receptor agonist tirzepatide for weight loss: a meta-analysis of randomized controlled trials
Objectives Tirzepatide is a dual glucose-dependent insulinotropic polypeptide and glucagon-like peptide-1 receptor agonist approved for type 2 diabetes. We performed a meta-analysis to assess tirzepatide’s weight reduction efficacy and safety. Methods We searched PubMed, Embase, and Cochrane for randomized controlled trials published from inception to July 2022, comparing tirzepatide with placebo for the co-primary endpoints of absolute and percent change in weight. Mean difference (MD) and odds ratio (OR) were calculated for continuous and binary outcomes, respectively. Review Manager 5.4.1 and RStudio were used for the statistical analysis, and RoB-2 (Cochrane) to assess the risk of bias. Results Of 397 search results, 6 studies (4036 participants) ranging from 12 to 72 weeks were included. Pooled analysis showed that tirzepatide 5 mg, 10 mg, and 15 mg were more effective than placebo, with MD in body weight of −7.7 kg (95% CI −11.0, −4.4; p < 0.001), −11.6 kg (95% CI −18.8, −4.3; p = 0.002), and −11.8 kg (95% CI −17.4, -6.2; p < 0.001), respectively, and MD in percent change in weight of −8.1% (95% CI −11.0, −5.2; p < 0.001), −11.9% (95% CI −18.1, −5.6; p < 0.001), and -12.4% (95% CI −17.2, −7.5; p < 0.001), respectively. Tirzepatide also reduced BMI and waist circumference. Adverse events were more common with tirzepatide with respect to nausea (OR 4.2; 95% CI 2.4, 7.5; p < 0.001), vomiting (OR 7.0; 95% CI 4.3, 11.4; p < 0.001), and diarrhea (OR 2.8; 95% CI 1.6, 4.9; p < 0.001) (15 mg dose), when compared with placebo. Conclusions The results support that tirzepatide leads to substantial weight reduction and constitutes a valuable therapeutic option for weight management, despite an increase in gastrointestinal symptoms. Protocol registration CRD42022348576.
- 17 July 2023
- Published by Springer Nature in International Journal of Obesity
- Vol. 47 (10) , 883-892
Efficacy and safety of the dual GIP and GLP-1 receptor agonist tirzepatide for weight loss: a meta-analysis of randomized controlled trials
Objectives Tirzepatide is a dual glucose-dependent insulinotropic polypeptide and glucagon-like peptide-1 receptor agonist approved for type 2 diabetes. We performed a meta-analysis to assess tirzepatide’s weight reduction efficacy and safety. Methods We searched PubMed, Embase, and Cochrane for randomized controlled trials published from inception to July 2022, comparing tirzepatide with placebo for the co-primary endpoints of absolute and percent change in weight. Mean difference (MD) and odds ratio (OR) were calculated for continuous and binary outcomes, respectively. Review Manager 5.4.1 and RStudio were used for the statistical analysis, and RoB-2 (Cochrane) to assess the risk of bias. Results Of 397 search results, 6 studies (4036 participants) ranging from 12 to 72 weeks were included. Pooled analysis showed that tirzepatide 5 mg, 10 mg, and 15 mg were more effective than placebo, with MD in body weight of −7.7 kg (95% CI −11.0, −4.4; p < 0.001), −11.6 kg (95% CI −18.8, −4.3; p = 0.002), and −11.8 kg (95% CI −17.4, -6.2; p < 0.001), respectively, and MD in percent change in weight of −8.1% (95% CI −11.0, −5.2; p < 0.001), −11.9% (95% CI −18.1, −5.6; p < 0.001), and -12.4% (95% CI −17.2, −7.5; p < 0.001), respectively. Tirzepatide also reduced BMI and waist circumference. Adverse events were more common with tirzepatide with respect to nausea (OR 4.2; 95% CI 2.4, 7.5; p < 0.001), vomiting (OR 7.0; 95% CI 4.3, 11.4; p < 0.001), and diarrhea (OR 2.8; 95% CI 1.6, 4.9; p < 0.001) (15 mg dose), when compared with placebo. Conclusions The results support that tirzepatide leads to substantial weight reduction and constitutes a valuable therapeutic option for weight management, despite an increase in gastrointestinal symptoms. Protocol registration CRD42022348576.
- 10 May 2023
- Published by Springer Nature in American Journal of Cardiovascular Drugs
- Vol. 23 (4) , 341-353
The Single-Syringe Versus the Double-Syringe Techniques of Adenosine Administration for Supraventricular Tachycardia: A Systematic Review and Meta-Analysis
Introduction The intravenous double-syringe technique (DST) of adenosine administration is the first-line treatment for stable supraventricular tachycardia (SVT). Alternatively, the single-syringe technique (SST) was recently found to be potentially beneficial in several studies. This study aimed to perform a meta-analysis of the SST versus the DST of adenosine administration for the treatment of SVT. Methods We assessed EMBASE, PubMed, Cochrane, and ClinicalTrials.gov databases for randomized controlled trials (RCTs) and non-randomized studies of intervention (NRSIs) comparing the DST to the SST of adenosine administration in patients with SVT. Outcomes included termination rate, termination rate at first dose, total administered dose, adverse effects, and discharge rate. Results We included four studies (three RCTs and one NRSI) with a total of 178 patients, of whom 99 underwent the SST of adenosine administration. No significant difference was found between treatment groups regarding termination rate, termination rate restricted to RCTs, total administered dose, and discharge rate. Termination rate at first dose (odds ratio 2.87; confidence interval 1.11–7.41; p = 0.03; I2 = 0%) was significantly increased in patients who received the SST. Major adverse effects were observed in only one study. Conclusions The SST is probably as safe as the DST and at least as effective for SVT termination, SVT termination at first dose, and discharge rate from the emergency department. However, definitive superiority of one technique is not feasible given the limited sample size. Registration PROSPERO identifier nº CRD42022345125.
- 10 May 2023
- Published by Springer Nature in American Journal of Cardiovascular Drugs
- Vol. 23 (4) , 341-353
The Single-Syringe Versus the Double-Syringe Techniques of Adenosine Administration for Supraventricular Tachycardia: A Systematic Review and Meta-Analysis
Introduction The intravenous double-syringe technique (DST) of adenosine administration is the first-line treatment for stable supraventricular tachycardia (SVT). Alternatively, the single-syringe technique (SST) was recently found to be potentially beneficial in several studies. This study aimed to perform a meta-analysis of the SST versus the DST of adenosine administration for the treatment of SVT. Methods We assessed EMBASE, PubMed, Cochrane, and ClinicalTrials.gov databases for randomized controlled trials (RCTs) and non-randomized studies of intervention (NRSIs) comparing the DST to the SST of adenosine administration in patients with SVT. Outcomes included termination rate, termination rate at first dose, total administered dose, adverse effects, and discharge rate. Results We included four studies (three RCTs and one NRSI) with a total of 178 patients, of whom 99 underwent the SST of adenosine administration. No significant difference was found between treatment groups regarding termination rate, termination rate restricted to RCTs, total administered dose, and discharge rate. Termination rate at first dose (odds ratio 2.87; confidence interval 1.11–7.41; p = 0.03; I2 = 0%) was significantly increased in patients who received the SST. Major adverse effects were observed in only one study. Conclusions The SST is probably as safe as the DST and at least as effective for SVT termination, SVT termination at first dose, and discharge rate from the emergency department. However, definitive superiority of one technique is not feasible given the limited sample size. Registration PROSPERO identifier nº CRD42022345125.