Jean Paquet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean Paquet has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Cournoyer
Université de Montréal, Montréal, Canada
3 shared publications - Raoul Daoust
Université de Montréal
2 shared publications - Éric Piette
Université de Montréal, Montréal, Canada
2 shared publications - Ann-Sophie Turcotte
Université de Montréal, Montréal, Canada
1 shared publication - Arnaud Robitaille
Medical Simulation Centre, Centre D’apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Université de Montréal, Pavillon Roger-Gaudry, 2900, Boulevard Édouard-Montpetit, 8e étage, Local N-805, Montréal, QC H3T 1J4, Canada
1 shared publication - Caroline Ranger
Department of Family Medicine and Emergency Medicine, Université de Montréal, Montréal, Canada
1 shared publication
Latest Publications
- 27 April 2026
- Published by Springer Nature in Canadian Journal of Emergency Medicine
- Vol. 28 (7) , 618-625
Point-of-care ultrasound-guided external aortic compression compared to manual external aortic compression: a prospective crossover trial on healthy volunteers
Objectives External compression of the abdominal aorta is a promising bridging therapy to reduce bleeding at non-compressible sites in trauma patients with hemorrhagic shock. This study aimed to evaluate femoral arterial flow reduction and pain associated with ultrasound-guided versus blind manual aortic-compression, performed by a low-weight versus medium-weight clinician. Methods We conducted a crossover experimental study on healthy volunteers. Ultrasound-guided and manual aortic-compression were performed by two physicians (80 kg and 54 kg). The primary outcome—originally defined as the difference in femoral blood flow reduction measured by Doppler—was modified early in data collection to the proportion of participants with complete flow occlusion, as this was found to be a more objective and physiologically relevant measure. Mixed models with two repeated measures compared complete occlusion between techniques and operator weights (alpha = 0.05). Pain scores and adverse effects at 0, 24 hour, and 7 days were also measured. Results The study was stopped after 20 volunteers underwent compression (mean BMI: 22; female: 65%) due to significant pain and two vasovagal syncopal episodes. Complete femoral flow occlusion was achieved using either technique in 19 (95%) and 17 (85%) participants for the 80-kg and 54-kg operators, respectively. No significant effect of technique was observed (p = 0.54). A trend toward an operator effect (greater effectiveness for the 80-kg operator; p = 0.07) was noted, with no interaction between operator weight and technique (p = 1.0). Conclusion This exploratory study on healthy volunteers suggests that both ultrasound-guided and manual external aortic-compression can achieve complete femoral arterial occlusion in most participants but cause significant pain and adverse events. Although the clinical implications remain uncertain, the procedure could be considered as a temporary, last resort measure for temporizing patients with severe, uncontrolled hemorrhagic shock. Registered at clinical.gov NCT04745585.
- 27 April 2026
- Published by Springer Nature in Canadian Journal of Emergency Medicine
- Vol. 28 (7) , 618-625
Point-of-care ultrasound-guided external aortic compression compared to manual external aortic compression: a prospective crossover trial on healthy volunteers
Objectives External compression of the abdominal aorta is a promising bridging therapy to reduce bleeding at non-compressible sites in trauma patients with hemorrhagic shock. This study aimed to evaluate femoral arterial flow reduction and pain associated with ultrasound-guided versus blind manual aortic-compression, performed by a low-weight versus medium-weight clinician. Methods We conducted a crossover experimental study on healthy volunteers. Ultrasound-guided and manual aortic-compression were performed by two physicians (80 kg and 54 kg). The primary outcome—originally defined as the difference in femoral blood flow reduction measured by Doppler—was modified early in data collection to the proportion of participants with complete flow occlusion, as this was found to be a more objective and physiologically relevant measure. Mixed models with two repeated measures compared complete occlusion between techniques and operator weights (alpha = 0.05). Pain scores and adverse effects at 0, 24 hour, and 7 days were also measured. Results The study was stopped after 20 volunteers underwent compression (mean BMI: 22; female: 65%) due to significant pain and two vasovagal syncopal episodes. Complete femoral flow occlusion was achieved using either technique in 19 (95%) and 17 (85%) participants for the 80-kg and 54-kg operators, respectively. No significant effect of technique was observed (p = 0.54). A trend toward an operator effect (greater effectiveness for the 80-kg operator; p = 0.07) was noted, with no interaction between operator weight and technique (p = 1.0). Conclusion This exploratory study on healthy volunteers suggests that both ultrasound-guided and manual external aortic-compression can achieve complete femoral arterial occlusion in most participants but cause significant pain and adverse events. Although the clinical implications remain uncertain, the procedure could be considered as a temporary, last resort measure for temporizing patients with severe, uncontrolled hemorrhagic shock. Registered at clinical.gov NCT04745585.
- 1 March 2020
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 38 (3) , 521-525
Can the “important brain injury criteria” predict neurosurgical intervention in mild traumatic brain injury? A validation study
- 1 March 2020
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 38 (3) , 521-525
Can the “important brain injury criteria” predict neurosurgical intervention in mild traumatic brain injury? A validation study
- Open Access
- 7 December 2018
- Published by Springer Nature in Advances in Simulation
- Vol. 3 (1) , 24
Transcutaneous cardiac pacing competency among junior residents undergoing an ACLS course: impact of a modified high fidelity manikin
Transcutaneous cardiac pacing (TCP) is recommended to treat unstable bradycardia. Simulation might improve familiarity with this low-frequency procedure. Current mannequins fail to reproduce key features of TCP, limiting their usefulness. The objective of this study was to measure the impact of a modified high-fidelity mannequin on the ability of junior residents to achieve six critical tasks for successful TCP. First-year residents from various postgraduate programs taking an advanced cardiovascular life support (ACLS) course were enrolled two consecutive years (2015 and 2016). Both cohorts received the same standardized course content. An ALS simulator® mannequin was used to demonstrate and practice TCP during the bradycardia workshop of the first cohort (control cohort, 2015) and a modified high-fidelity mannequin that reproduces key features of TCP was used for the second cohort (intervention cohort, 2016). Participants were tested after training with a simulation scenario requiring TCP. Performances were graded based on six critical tasks. The primary outcome was the successful use of TCP, defined as having completed all tasks. Eighteen participants in the intervention cohort completed all tasks during the simulation scenario compared to none in the control cohort (36 vs 0%, p < 0.001). Participants in the intervention cohort were more likely to recognize when pacing was inefficient (86 vs 12%), obtain ventricular capture (48 vs 2%), and check for a pulse rate to confirm capture (48 vs 0%). TCP is a difficult skill to master for junior residents. Training using a modified high-fidelity mannequin significantly improved their ability to establish TCP during a simulation scenario.
- 7 December 2018
- Published by Springer Nature in Advances in Simulation
- Vol. 3 (1) , 24
Open AccessTranscutaneous cardiac pacing competency among junior residents undergoing an ACLS course: impact of a modified high fidelity manikin
Transcutaneous cardiac pacing (TCP) is recommended to treat unstable bradycardia. Simulation might improve familiarity with this low-frequency procedure. Current mannequins fail to reproduce key features of TCP, limiting their usefulness. The objective of this study was to measure the impact of a modified high-fidelity mannequin on the ability of junior residents to achieve six critical tasks for successful TCP. First-year residents from various postgraduate programs taking an advanced cardiovascular life support (ACLS) course were enrolled two consecutive years (2015 and 2016). Both cohorts received the same standardized course content. An ALS simulator® mannequin was used to demonstrate and practice TCP during the bradycardia workshop of the first cohort (control cohort, 2015) and a modified high-fidelity mannequin that reproduces key features of TCP was used for the second cohort (intervention cohort, 2016). Participants were tested after training with a simulation scenario requiring TCP. Performances were graded based on six critical tasks. The primary outcome was the successful use of TCP, defined as having completed all tasks. Eighteen participants in the intervention cohort completed all tasks during the simulation scenario compared to none in the control cohort (36 vs 0%, p < 0.001). Participants in the intervention cohort were more likely to recognize when pacing was inefficient (86 vs 12%), obtain ventricular capture (48 vs 2%), and check for a pulse rate to confirm capture (48 vs 0%). TCP is a difficult skill to master for junior residents. Training using a modified high-fidelity mannequin significantly improved their ability to establish TCP during a simulation scenario.