Abel Guzmán Calvete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abel Guzmán Calvete has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Alejandra Kontides
Med-EL, Innsbruck, Austria
1 shared publication - Alexandra Cortés-Arciniegas
Department of Otorhinolaryngology, Hospital Universitari i Politècnic La Fe, Valencia, Spain
1 shared publication - Carlos De Paula-Vernetta
Servicio de Otorrinolaringología, Hospital Universitario y Politécnico La Fe, Valencia, España
1 shared publication - Carlos de Paula Vernetta
Department of ENT, La Fe University and Polytechnic Hospital, Valencia, Spain
1 shared publication - Kathrin Lauss
R&D, MED-EL Medical Electronics
1 shared publication - Konrad Schwarz
MED-EL GMBH
1 shared publication
Latest Publications
- Open Access
- 21 September 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (5) , 1-9
The Current Role of Blue Laser in Otologic Surgery: A Narrative Review
Blue laser technology, specifically the 445-450 nm wavelength blue diode laser, represents an emerging innovation in otologic surgery with unique photoangiolytic and hemostatic properties. This narrative review discusses evidence from otologic studies directly addressing the 445-450 nm blue diode laser to evaluate the clinical applications, outcomes, and safety profile of blue laser systems in ear surgery. The technology hasbeen explored in stapedotomy procedures for otosclerosis, middle ear paraganglioma excision, and cholesteatoma surgery. Preliminary and still limited clinical data suggest audiological outcomes broadly comparable to traditional carbon dioxide laser systems, with a proposed advantage in hemostasis and thermal. Direct otologic evidence remains limited to a small number of case series and retrospective comparisons, with most publications emerging between 2018 and 2025. This review identifies blue laser technology as a promising adjunct to the otologic surgeon’s armamentarium, warranting larger randomized controlled trials to establish definitive clinical guidelines and long-term safety profiles.
- 21 September 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (5) , 1-9
Open AccessThe Current Role of Blue Laser in Otologic Surgery: A Narrative Review
Blue laser technology, specifically the 445-450 nm wavelength blue diode laser, represents an emerging innovation in otologic surgery with unique photoangiolytic and hemostatic properties. This narrative review discusses evidence from otologic studies directly addressing the 445-450 nm blue diode laser to evaluate the clinical applications, outcomes, and safety profile of blue laser systems in ear surgery. The technology hasbeen explored in stapedotomy procedures for otosclerosis, middle ear paraganglioma excision, and cholesteatoma surgery. Preliminary and still limited clinical data suggest audiological outcomes broadly comparable to traditional carbon dioxide laser systems, with a proposed advantage in hemostasis and thermal. Direct otologic evidence remains limited to a small number of case series and retrospective comparisons, with most publications emerging between 2018 and 2025. This review identifies blue laser technology as a promising adjunct to the otologic surgeon’s armamentarium, warranting larger randomized controlled trials to establish definitive clinical guidelines and long-term safety profiles.
- Open Access
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (3) , 353-358
Comparison of a Traditional and Novel Evoked Compound Action Potentials Recording Approach and Evoked Auditory Brainstem Responses in Pediatric Cochlear Implants Users
OBJECTIVES: Electrically evoked compound action potentials (eCAP) recordings are widely used in functional evaluation and fitting of cochlear implants (CI) in clinics. We compared the results from two eCAP recording approaches (StandardART and FineGrain, MED-EL, Austria). The FineGrain method is more advanced than the Auditory Nerve Response Telemetry (StandardART) method in terms of the stimulation and algorithm for the eCAP threshold detection. To understand the benefits of these alterations, we compared the two methods on a larger scale in pediatric CI users alongside evoked auditory brainstem responses (eABR). MATERIALS and METHODS: We collected the eCAP recordings obtained with both methods from a population of pediatric subjects with CI, either intra- or post-operatively. The eABR recordings were only collected post-operatively. For comparability reasons, we used the same stimulation rate and similar amplitude levels for all three approaches. RESULTS: Our results demonstrate that, although the success rates are similar, the FineGrain method outperforms traditional StandardART in terms of robustness and measurement duration. The eCAP recordings in general outperform the eABR in terms of speed. CONCLUSION: We conclude that the eCAP recordings are the method of choice for measuring the auditory neural activity, and FineGrain outperforms StandardART. From the three investigated approaches, we conclude that FineGrain performed best and should be the first-choice method in pediatric patients. Cite this article as: Cavalle Garrido L, Schwarz K, Lauss K, de Paula Vernetta C, Kontides A, Diaz Gomez M, et al. Comparison of a Traditional and Novel Evoked Compound Action Potentials Recording Approach and Evoked Auditory Brainstem Responses in Pediatric Cochlear Implants Users. J Int Adv Otol 2018; 14(3): 353-8.
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (3) , 353-358
Open AccessComparison of a Traditional and Novel Evoked Compound Action Potentials Recording Approach and Evoked Auditory Brainstem Responses in Pediatric Cochlear Implants Users
OBJECTIVES: Electrically evoked compound action potentials (eCAP) recordings are widely used in functional evaluation and fitting of cochlear implants (CI) in clinics. We compared the results from two eCAP recording approaches (StandardART and FineGrain, MED-EL, Austria). The FineGrain method is more advanced than the Auditory Nerve Response Telemetry (StandardART) method in terms of the stimulation and algorithm for the eCAP threshold detection. To understand the benefits of these alterations, we compared the two methods on a larger scale in pediatric CI users alongside evoked auditory brainstem responses (eABR). MATERIALS and METHODS: We collected the eCAP recordings obtained with both methods from a population of pediatric subjects with CI, either intra- or post-operatively. The eABR recordings were only collected post-operatively. For comparability reasons, we used the same stimulation rate and similar amplitude levels for all three approaches. RESULTS: Our results demonstrate that, although the success rates are similar, the FineGrain method outperforms traditional StandardART in terms of robustness and measurement duration. The eCAP recordings in general outperform the eABR in terms of speed. CONCLUSION: We conclude that the eCAP recordings are the method of choice for measuring the auditory neural activity, and FineGrain outperforms StandardART. From the three investigated approaches, we conclude that FineGrain performed best and should be the first-choice method in pediatric patients. Cite this article as: Cavalle Garrido L, Schwarz K, Lauss K, de Paula Vernetta C, Kontides A, Diaz Gomez M, et al. Comparison of a Traditional and Novel Evoked Compound Action Potentials Recording Approach and Evoked Auditory Brainstem Responses in Pediatric Cochlear Implants Users. J Int Adv Otol 2018; 14(3): 353-8.