Tiannian Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tiannian Zhou has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Yu Liu
State Key Laboratory of Disaster Prevention & Reduction for Power Grid, Changsha 410129, China
4 shared publications - Jian Wang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, China
3 shared publications - Baohui Chen
State Key Laboratory of Disaster Prevention & Reduction for Power Grid, State Grid Hunan Electric Company Limited Disaster Prevention and Reduction Center, Changsha 410007, China
2 shared publications - Chuanping Wu
Disaster Prevention and Reduction Center, State Grid Hunan Electric Power Company Ltd
2 shared publications Baohui Chen
State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, State Grid Hunan Electric Company Limited Disaster Prevention and Reduction Center, Changsha, Hunan, P.R. China
1 shared publication- Bichen Pan
State Key Laboratory of Disaster Prevention and Reduction for Power Grid, State Grid Hunan Electric Power Company Limited, Changsha 410129, China
1 shared publication
Latest Publications
- Open Access
Development and Evaluation of Steel Component Coatings for Substations/Converter Stations with Both Fire and Corrosion Prevention Functions
There are a large number of steel components in substations/converter stations whose performance is seriously affected by being exposed to environmental corrosion and fire, endangering the operation of the substation/converter station. The current protective measures for steel components in substations/converter stations primarily involve the application of anti-corrosion and fireproof coatings. However, these coatings can easily peel off, resulting in a significant loss of their protective effectiveness. In response to this challenge, a new type of silicone-modified epoxy resin substrate has been synthesized by chemically grafting silicone resin onto epoxy resin segments, which retains the high adhesion of epoxy resin while enhancing its weather resistance. The use of synthesized nano zinc oxide-modified graphene oxide as a fireproof filler significantly improves the physical barrier effect and corrosion resistance of the coating. Additionally, the innovative addition of new metal anti-corrosion active pigments improves the adhesion and impermeability of the coating. Therefore, a steel structure coating for substations/converter stations with both fire and corrosion prevention functions has been developed. Standard tests conducted by national institutions have shown that the coating meets the performance requirements.
Open AccessDevelopment and Evaluation of Steel Component Coatings for Substations/Converter Stations with Both Fire and Corrosion Prevention Functions
There are a large number of steel components in substations/converter stations whose performance is seriously affected by being exposed to environmental corrosion and fire, endangering the operation of the substation/converter station. The current protective measures for steel components in substations/converter stations primarily involve the application of anti-corrosion and fireproof coatings. However, these coatings can easily peel off, resulting in a significant loss of their protective effectiveness. In response to this challenge, a new type of silicone-modified epoxy resin substrate has been synthesized by chemically grafting silicone resin onto epoxy resin segments, which retains the high adhesion of epoxy resin while enhancing its weather resistance. The use of synthesized nano zinc oxide-modified graphene oxide as a fireproof filler significantly improves the physical barrier effect and corrosion resistance of the coating. Additionally, the innovative addition of new metal anti-corrosion active pigments improves the adhesion and impermeability of the coating. Therefore, a steel structure coating for substations/converter stations with both fire and corrosion prevention functions has been developed. Standard tests conducted by national institutions have shown that the coating meets the performance requirements.
- Open Access
Experimental Study and Application of Unmanned Aerial Vehicle Releasing Fire-Extinguishing Bomb on Transmission Line Wildfires
Experimental studies on the application of unmanned aerial vehicles (UAVs) to extinguish high-repeatability transmission line wildfires are not available. In this study, a scheme involving a UAV releasing a fire-extinguishing bomb at a high altitude for firefighting was proposed, and a simulated fire-extinguishing experimental platform was constructed to simulate a UAV releasing a fire-extinguishing bomb. In addition, the characteristics of water-based fire-extinguishing bombs of 5, 10, 20, and 50 kg as well as dry powder bombs of 25, 30, and 50 kg were investigated by changing parameters such as the type and mass of the fire-extinguishing agent carried by the bombs. It was noted that a 30 kg or more dry powder fire-extinguishing bomb could extinguish a fire in four 1A cribs at one time. The diffusion area of the fire-extinguishing medium was obtained from the perspective of the UAV. The diffusion area was 45–90 m2 for the water-based fire-extinguishing bomb and 130–700 m2 for the dry powder bomb. As calculated from the area of the fire scene extinguished by each fire-extinguishing bomb per unit mass, the utilization rate of a fire-extinguishing medium was highest with the 30 kg fire-extinguishing bomb, followed by the 50 kg bomb. In the high wildfire incidence period during the Qingming Festival in 2024, a UAV was used to release fire-extinguishing bombs to extinguish an incipient wildfire near a transmission line at a Hunan Power Grid site.
Open AccessExperimental Study and Application of Unmanned Aerial Vehicle Releasing Fire-Extinguishing Bomb on Transmission Line Wildfires
Experimental studies on the application of unmanned aerial vehicles (UAVs) to extinguish high-repeatability transmission line wildfires are not available. In this study, a scheme involving a UAV releasing a fire-extinguishing bomb at a high altitude for firefighting was proposed, and a simulated fire-extinguishing experimental platform was constructed to simulate a UAV releasing a fire-extinguishing bomb. In addition, the characteristics of water-based fire-extinguishing bombs of 5, 10, 20, and 50 kg as well as dry powder bombs of 25, 30, and 50 kg were investigated by changing parameters such as the type and mass of the fire-extinguishing agent carried by the bombs. It was noted that a 30 kg or more dry powder fire-extinguishing bomb could extinguish a fire in four 1A cribs at one time. The diffusion area of the fire-extinguishing medium was obtained from the perspective of the UAV. The diffusion area was 45–90 m2 for the water-based fire-extinguishing bomb and 130–700 m2 for the dry powder bomb. As calculated from the area of the fire scene extinguished by each fire-extinguishing bomb per unit mass, the utilization rate of a fire-extinguishing medium was highest with the 30 kg fire-extinguishing bomb, followed by the 50 kg bomb. In the high wildfire incidence period during the Qingming Festival in 2024, a UAV was used to release fire-extinguishing bombs to extinguish an incipient wildfire near a transmission line at a Hunan Power Grid site.
- Open Access
A Multistage Current Charging Method for Energy Storage Device of Microgrid Considering Energy Consumption and Capacity of Lithium Battery
Modular multilevel converter battery energy storage systems (MMC-BESSs) have become an important device for the energy storage of grid-connected microgrids. The efficiency of the power transmission of MMC-BESSs has become a new research hotspot. This paper outlines a multi-stage charging method to minimize energy consumption and maximize the capacity of MMC-BESSs. Firstly, based on condition monitoring and data collection, the functional relationship between the internal resistance/capacity and other states of lithium batteries is established. Since the energy consumption of the battery is related to internal resistance, current, and time, the energy consumption calculation expression of the battery pack is established, and the objective function is designed to optimize energy consumption and capacity in order to determine the charging current curve of each stage. Compared with the constant current charging method, the proposed multistage current charging method for an MMC-BESS decreases energy consumption by 4.3% and increases the capacity of 5 SOC intervals by 1.56%.
Open AccessA Multistage Current Charging Method for Energy Storage Device of Microgrid Considering Energy Consumption and Capacity of Lithium Battery
Modular multilevel converter battery energy storage systems (MMC-BESSs) have become an important device for the energy storage of grid-connected microgrids. The efficiency of the power transmission of MMC-BESSs has become a new research hotspot. This paper outlines a multi-stage charging method to minimize energy consumption and maximize the capacity of MMC-BESSs. Firstly, based on condition monitoring and data collection, the functional relationship between the internal resistance/capacity and other states of lithium batteries is established. Since the energy consumption of the battery is related to internal resistance, current, and time, the energy consumption calculation expression of the battery pack is established, and the objective function is designed to optimize energy consumption and capacity in order to determine the charging current curve of each stage. Compared with the constant current charging method, the proposed multistage current charging method for an MMC-BESS decreases energy consumption by 4.3% and increases the capacity of 5 SOC intervals by 1.56%.
- 6 July 2020
- Published by Springer Nature in Fire Technology
- Vol. 57 (1) , 461-481
Experimental Study on Burning Characteristics of the Large-Scale Transformer Oil Pool Fire with Different Extinguishing Methods
- 6 July 2020
- Published by Springer Nature in Fire Technology
- Vol. 57 (1) , 461-481
Experimental Study on Burning Characteristics of the Large-Scale Transformer Oil Pool Fire with Different Extinguishing Methods
- 2 March 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 143 (4) , 3057-3064
Experimental study on combustion and yield characteristics of dimethyl carbonate/n-heptane blends in the cone calorimeter
- 2 March 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 143 (4) , 3057-3064
Experimental study on combustion and yield characteristics of dimethyl carbonate/n-heptane blends in the cone calorimeter
- Open Access
- 4 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (7) , 1431
Investigation on Smoke Flow in Stairwells induced by an Adjacent Compartment Fire in High Rise Buildings
The aim of this study was to evaluate the transport phenomena of smoke flow and vertical temperature distribution in a 21-story stairwell with multiple fire locations and openings. A large eddy simulation (LES) method was used to model the smoke flow in a stairwell model with a set of simulation parameters, wherein the fire heat release rate (HRR) and fire location were varied. Based on the results, a wall attachment effect was found in three-dimensional figures. Moreover, with an increase in the fire HRR, the effects were more pronounced. The simulation results verified that the vertical temperature distribution is an index model with a natural logarithm, where the pre-finger factor and attenuation coefficient increase considerably in accordance with an increase in the fire HRR. Moreover, there was a decrease in the maximum temperature (Tm) with an increase in the fire location factor (h*) due to the upward thermal smoke. Moreover, heat mainly accumulates in the area above a fire source. However, h* has a slight influence on the time required to reach Tm within the range of 53–64 s. Furthermore, the direction of the airflow at each side opening in the stairwell varied in accordance with the variation in the fire location changes, and a regular calculation was carried out.
- 4 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (7) , 1431
Open AccessInvestigation on Smoke Flow in Stairwells induced by an Adjacent Compartment Fire in High Rise Buildings
The aim of this study was to evaluate the transport phenomena of smoke flow and vertical temperature distribution in a 21-story stairwell with multiple fire locations and openings. A large eddy simulation (LES) method was used to model the smoke flow in a stairwell model with a set of simulation parameters, wherein the fire heat release rate (HRR) and fire location were varied. Based on the results, a wall attachment effect was found in three-dimensional figures. Moreover, with an increase in the fire HRR, the effects were more pronounced. The simulation results verified that the vertical temperature distribution is an index model with a natural logarithm, where the pre-finger factor and attenuation coefficient increase considerably in accordance with an increase in the fire HRR. Moreover, there was a decrease in the maximum temperature (Tm) with an increase in the fire location factor (h*) due to the upward thermal smoke. Moreover, heat mainly accumulates in the area above a fire source. However, h* has a slight influence on the time required to reach Tm within the range of 53–64 s. Furthermore, the direction of the airflow at each side opening in the stairwell varied in accordance with the variation in the fire location changes, and a regular calculation was carried out.
- 27 February 2019
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 192 (4) , 592-609
Investigation of the Fire-Extinguishing Performance of Water Mist with Various Additives on Typical Pool Fires
To investigate the efficiency of water mist with additives on suppressing the typical pool fires including gasoline fire, diesel fire and transformer oil fire, a water mist generating system was employed to conduct a series of fire-extinguishing experiments. In this paper, the suppression effectiveness of the pure water mist was used to compare with the water mist containing additives, which comprises of KHCO3, carbamide, cocamidopropyl betaine and Capstone FS-1157. Meanwhile, the corresponding temperature characteristics and flame shape were measured and recorded. Results demonstrated that the fire-extinguishing performance of the water mist was improved significantly by containing additives. Wherein, the suppression efficiency of carbamide was higher than that of KHCO3 and surfactant because its decomposition reaction absorbed a large amount of heat, as a result, leading to reduction in the flame temperature. Also, the flame-retardant gases were generated and they can dilute oxygen concentration in the combustion region. However, the surfactant was better to be selected as the additive of water mist for the transformer oil fires in comparison with other additives. In contrast to the pure water mist, the average fire-extinguishing time was greatly reduced, particularly for the Capstone FS-1157. This is because the emulsification of surface-active agent plays a key role for heavy oil in the suppression process.
- 27 February 2019
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 192 (4) , 592-609
Investigation of the Fire-Extinguishing Performance of Water Mist with Various Additives on Typical Pool Fires
To investigate the efficiency of water mist with additives on suppressing the typical pool fires including gasoline fire, diesel fire and transformer oil fire, a water mist generating system was employed to conduct a series of fire-extinguishing experiments. In this paper, the suppression effectiveness of the pure water mist was used to compare with the water mist containing additives, which comprises of KHCO3, carbamide, cocamidopropyl betaine and Capstone FS-1157. Meanwhile, the corresponding temperature characteristics and flame shape were measured and recorded. Results demonstrated that the fire-extinguishing performance of the water mist was improved significantly by containing additives. Wherein, the suppression efficiency of carbamide was higher than that of KHCO3 and surfactant because its decomposition reaction absorbed a large amount of heat, as a result, leading to reduction in the flame temperature. Also, the flame-retardant gases were generated and they can dilute oxygen concentration in the combustion region. However, the surfactant was better to be selected as the additive of water mist for the transformer oil fires in comparison with other additives. In contrast to the pure water mist, the average fire-extinguishing time was greatly reduced, particularly for the Capstone FS-1157. This is because the emulsification of surface-active agent plays a key role for heavy oil in the suppression process.
- Open Access
- 17 October 2018
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 28 (11) , 2664-2680
Transport phenomena of fire-induced smoke flow in a semi-open vertical shaft
Purpose: The purpose of this study is to investigate the transport phenomena of smoke flow in a semi-open vertical shaft. Design/methodology/approach: The large eddy simulation (LES) method was used to model the movement of fire-induced thermal flow in a full-scale vertical shaft. With this model, different fire locations and heat release rates (HRRs) were considered simultaneously. Findings: It was determined that the burning intensity of the fire is enhanced when the fire attaches to the sidewall, resulting in a larger continuous flame region in the compartment and higher temperatures of the spill plume in the shaft compared to a center fire. In the initial stage of the fire with a small HRR, the buoyancy-driven spill plumes incline toward the side of the shaft opposite the window. Meanwhile, the thermal plumes are also directed away from the center of the shaft by the entrained airflow, but the inclination diminishes as HRR increases. This is because a greater HRR produces higher temperatures, resulting in a stronger buoyancy to drive smoke movement evenly in the shaft. In addition, a dimensionless equation was proposed to predict the rise-time of the smoke plume front in the shaft. Research limitations/implications: The results need to be verified with experiments. Practical implications: The results could be applied for design and assessment of semi-open shafts. Originality/value: This study shows the transport phenomena of smoke flow in a vertical shaft with one open side.
- 17 October 2018
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 28 (11) , 2664-2680
Open AccessTransport phenomena of fire-induced smoke flow in a semi-open vertical shaft
Purpose: The purpose of this study is to investigate the transport phenomena of smoke flow in a semi-open vertical shaft. Design/methodology/approach: The large eddy simulation (LES) method was used to model the movement of fire-induced thermal flow in a full-scale vertical shaft. With this model, different fire locations and heat release rates (HRRs) were considered simultaneously. Findings: It was determined that the burning intensity of the fire is enhanced when the fire attaches to the sidewall, resulting in a larger continuous flame region in the compartment and higher temperatures of the spill plume in the shaft compared to a center fire. In the initial stage of the fire with a small HRR, the buoyancy-driven spill plumes incline toward the side of the shaft opposite the window. Meanwhile, the thermal plumes are also directed away from the center of the shaft by the entrained airflow, but the inclination diminishes as HRR increases. This is because a greater HRR produces higher temperatures, resulting in a stronger buoyancy to drive smoke movement evenly in the shaft. In addition, a dimensionless equation was proposed to predict the rise-time of the smoke plume front in the shaft. Research limitations/implications: The results need to be verified with experiments. Practical implications: The results could be applied for design and assessment of semi-open shafts. Originality/value: This study shows the transport phenomena of smoke flow in a vertical shaft with one open side.