KGKaiyun Gu

Kaiyun Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaiyun Gu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computational analysis of the hemodynamic characteristics under interaction influence of β-blocker and LVAD

    by Kaiyun Gu, Zhe Zhang, Yu Chang, Bin Gao, Feng Wan

    Hemodynamic characteristics of the interaction influence among support level and model of LVAD, and coupling β-blocker has not been reported. In this study, the effect of support level and model of LVAD on cardiovascular hemodynamic characteristics is investigated. In addition, the effect of β-blocker on unloading with LVAD is analyzed to elucidate the mechanism of LVAD coupling β-blocker. A multi-scale model from cell level to system level is proposed. Moreover, LVAD coupling β-blocker has been researching to explain the hemodynamics of cardiovascular system. Myocardial force was decreased along with the increase of support level of LVAD, and co-pulse mode was the lowest among the three support modes. Additionally, the β-blocker combined with LVAD significantly reduced the left ventricular volume compared with LVAD support without β-blocker. However, the left ventricular pressure under both cases has no significant difference. External work of right ventricular was increased along with the growth of support level of only LVAD. The LVAD under co-pulse mode achieved the lowest right-ventricular EW among the three support modes. Co-pulse mode with β-blocker could be an optimal strategy for promoting cardiac structure and function recovery.


  • Open Access

    Hemodynamic effects of perfusion level of peripheral ECMO on cardiovascular system

    by Kaiyun Gu, Zhe Zhang, Bin Gao, Yu Chang, Feng Wan

    Peripheral ECMO is an effective cardiopulmonary support in clinical. The perfusion level could directly influence the performances and complications. However, there are few studies on the effects of the perfusion level on hemodynamics of peripheral ECMO. The geometric model of cardiovascular system with peripheral ECMO was established. The blood assist index was used to classify the perfusion level of the ECMO. The flow pattern from the aorta to the femoral artery and their branches, blood flow rate from aorta to brain and limbs, flow interface, harmonic index of blood flow, wall shear stress and oscillatory shear index were chosen to evaluate the hemodynamic effects of peripheral ECMO. The results demonstrated that the flow rate of aorta outlets increased and perfusion condition had been improved. And the average flow to the upper limbs and brain has a positive correlation with BAI (r = 0.037, p < 0.05), while there is a negative correlation with lower limbs (r = − 0.054, p < 0.05). The HI has negative correlation with BAI (p < 0.05, r < 0). The blood interface is further from the heart with the BAI decrease. And the average WSS has negative correlation with BAI (p < 0.05, r = − 0.983) at the bifurcation of femoral aorta and has positive correlation with BAI (p < 0.05, r = 0.99) at the inner aorta. The OSI under different BAI is higher (reaching 0.4) at the inner wall of the aortic arch, the descending aorta and the femoral access. The pathogenesis of peripheral ECMO with different perfusion levels varies; its further research will be thorough and extensive.