Andrew Cannon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrew Cannon has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Jessica Peacock
1 shared publication- John A. Gallagher
Merrimack College
1 shared publication Kaylyn Stewart
1 shared publicationKevin Finn
Merrimack College, School of Health Sciences, North Andover, MA, USA
1 shared publication- Tori N. Thistle
Department of Mechanical Engineering, Merrimack College, 315 Turnpike Street, North Andover, MA 01845
1 shared publication Zi Yan
Merrimack College, School of Health Sciences, North Andover, MA, USA
1 shared publication
Latest Publications
- 1 July 2020
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 52 (7S) , 385
Collegiate Club Figure Skater Lower Extremity Performance Assessment Bilaterally In And Out Of Skates
- 1 July 2020
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 52 (7S) , 385
Collegiate Club Figure Skater Lower Extremity Performance Assessment Bilaterally In And Out Of Skates
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
Pressure Distribution Across the Handle of an Instrument-Assisted Soft Tissue Mobilization Tool
Instrument-assisted soft tissue mobilization (IASTM) tools are used during rehabilitative care for treatment of injuries to muscles, tendons, and ligaments. Many studies have quantified treatment application forces between tools and the patient. However, the effect of force on the clinician has not been studied even though research shows that clinicians experience discomfort and fatigue during treatment. This work presents a method to accurately measure the pressure profile between the IASTM tool handle and hand of the clinician. Flexible pressure indicating film was used to measure the pressure magnitude and distribution on the hand. These tests were performed at varying treatment application forces between 15 and 60 N, normal to the treatment surface. The tests were repeated, and forces were compared between 3D-printed designs. The pressure profile on the user was explored by changing aspects of the handle design. Results are analyzed and discussed as an effect of changing handle dimensions. As the diameter of the handle increased, the pressure magnitude decreased while the pressure distribution across the hand increased. Changing the contour of the handle further decreased the magnitude and increased the distribution. This procedure is not specific to the chosen tool and can be repeated for other tools.
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
Pressure Distribution Across the Handle of an Instrument-Assisted Soft Tissue Mobilization Tool
Instrument-assisted soft tissue mobilization (IASTM) tools are used during rehabilitative care for treatment of injuries to muscles, tendons, and ligaments. Many studies have quantified treatment application forces between tools and the patient. However, the effect of force on the clinician has not been studied even though research shows that clinicians experience discomfort and fatigue during treatment. This work presents a method to accurately measure the pressure profile between the IASTM tool handle and hand of the clinician. Flexible pressure indicating film was used to measure the pressure magnitude and distribution on the hand. These tests were performed at varying treatment application forces between 15 and 60 N, normal to the treatment surface. The tests were repeated, and forces were compared between 3D-printed designs. The pressure profile on the user was explored by changing aspects of the handle design. Results are analyzed and discussed as an effect of changing handle dimensions. As the diameter of the handle increased, the pressure magnitude decreased while the pressure distribution across the hand increased. Changing the contour of the handle further decreased the magnitude and increased the distribution. This procedure is not specific to the chosen tool and can be repeated for other tools.
- 1 December 2018
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 13 (6) , 956-962
COMPARISON OF HIP INTERNAL AND EXTERNAL ROTATION BETWEEN INTERCOLLEGIATE DISTANCE RUNNERS AND NON-RUNNING COLLEGE STUDENTS
Background: The increased incidence of lower extremity injury in runners compared to the general population is well documented. The amount of passive hip rotation and the position of hip flexion or extension at which it occurs may be factors related to injury incidence. Purpose: The purpose of the current study was to measure and compare hip rotation passive range of motion in male and female runners and non-runners at 0 and 90 degrees (degrees) of hip flexion. Study Design: Descriptive Laboratory Study. Methods: Eighteen Division II collegiate distance runners (9 female, 9 male, mean age =19.1, + /- 1.1 years) who had run for an average of 7.1 (SD =1.7) years participated in the study. Twenty non-runners (10 female, 10 male, mean age =19.6, + /- 1.1 years) from the same institution were also recruited. Passive hip internal rotation (IR) and external rotation (ER) were measured with a universal goniometer in 90 degrees of hip flexion in a seated position, and in 0 degrees of hip flexion in prone position. Results: There was a significant difference in IR measured in 0 degrees of hip flexion, between runners and non-runners (F(1,37) = 8.04, p = .007). Additionally, the difference in IR between males (36.68 +/-9.19 degrees) and females (45.99 +/- 9.12) was significantly different (F(1,37) = 20.79, p = .001). There were no other statistically significant differences in measurements between groups. Conclusions: Collegiate runners had significantly greater passive hip IR when measured at 0 degrees of hip flexion compared to the non-runners. Female runners had significantly greater passive hip IR compared to the male participants across both runners and non-runners.
- 1 December 2018
- Published by International Journal of Sports Physical Therapy in International Journal of Sports Physical Therapy
- Vol. 13 (6) , 956-962
COMPARISON OF HIP INTERNAL AND EXTERNAL ROTATION BETWEEN INTERCOLLEGIATE DISTANCE RUNNERS AND NON-RUNNING COLLEGE STUDENTS
Background: The increased incidence of lower extremity injury in runners compared to the general population is well documented. The amount of passive hip rotation and the position of hip flexion or extension at which it occurs may be factors related to injury incidence. Purpose: The purpose of the current study was to measure and compare hip rotation passive range of motion in male and female runners and non-runners at 0 and 90 degrees (degrees) of hip flexion. Study Design: Descriptive Laboratory Study. Methods: Eighteen Division II collegiate distance runners (9 female, 9 male, mean age =19.1, + /- 1.1 years) who had run for an average of 7.1 (SD =1.7) years participated in the study. Twenty non-runners (10 female, 10 male, mean age =19.6, + /- 1.1 years) from the same institution were also recruited. Passive hip internal rotation (IR) and external rotation (ER) were measured with a universal goniometer in 90 degrees of hip flexion in a seated position, and in 0 degrees of hip flexion in prone position. Results: There was a significant difference in IR measured in 0 degrees of hip flexion, between runners and non-runners (F(1,37) = 8.04, p = .007). Additionally, the difference in IR between males (36.68 +/-9.19 degrees) and females (45.99 +/- 9.12) was significantly different (F(1,37) = 20.79, p = .001). There were no other statistically significant differences in measurements between groups. Conclusions: Collegiate runners had significantly greater passive hip IR when measured at 0 degrees of hip flexion compared to the non-runners. Female runners had significantly greater passive hip IR compared to the male participants across both runners and non-runners.