Wei Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Long has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Huaguo Liu
School of Mechanical Engineering Sichuan University Chengdu China
1 shared publication- Jianping Yue
School of Mechanical Engineering Sichuan University Chengdu China
1 shared publication - Li Zeng
School of Mechatronics and Vehicle Engineering, Chongqing Jiaotong University, Chongqing 400074, China
1 shared publication Shuaishuai Guo
School of Mechanical Engineering Sichuan University Chengdu China
1 shared publication- Yanyan Li
School of Mechanical Engineering, Sichuan University, Chengdu 610065, China
1 shared publication
Latest Publications
- 29 July 2020
- Published by Wiley in Process Safety Progress
- Vol. 40 (1)
A novel detonation arrester containing a large disk with long triangular slits: Design and numerical simulation
Aiming at the problem that common flame arresters can only extinguish deflagration flame, but cannot effectively extinguish detonation flame in large pipelines, this paper proposes a novel structure of detonation arrester based on heat transfer theory to improve the detonation flame extinguishing efficiency. The flame arresting element is composed of a large disk with long triangular slits and is used as the quenching part of detonation arrester in a monolithic structure. Compared with common flame arrester consists of several small fires retarding elements, the proposed monolithic structure is safer due to its integrity. In addition, this paper explores the relationship between flame extinguishing ability, detonation pressure, and temperature change. This investigation determined that the diameter of the quenching part and the parameters(length and height) of the long triangular slits were the key factors affecting the quenching characteristics, and as the diameter and porosity increase, the detonation pressure at the front of the flame arrester will decrease. Finally, the rationality and applicability of the structure are verified by simulation experiments. These preliminary conclusions are helpful to reveal the nature of the proposed structure and solve the technical problem of preventing detonation flame propagation of coal mine gas in large pipelines.
- 29 July 2020
- Published by Wiley in Process Safety Progress
- Vol. 40 (1)
A novel detonation arrester containing a large disk with long triangular slits: Design and numerical simulation
Aiming at the problem that common flame arresters can only extinguish deflagration flame, but cannot effectively extinguish detonation flame in large pipelines, this paper proposes a novel structure of detonation arrester based on heat transfer theory to improve the detonation flame extinguishing efficiency. The flame arresting element is composed of a large disk with long triangular slits and is used as the quenching part of detonation arrester in a monolithic structure. Compared with common flame arrester consists of several small fires retarding elements, the proposed monolithic structure is safer due to its integrity. In addition, this paper explores the relationship between flame extinguishing ability, detonation pressure, and temperature change. This investigation determined that the diameter of the quenching part and the parameters(length and height) of the long triangular slits were the key factors affecting the quenching characteristics, and as the diameter and porosity increase, the detonation pressure at the front of the flame arrester will decrease. Finally, the rationality and applicability of the structure are verified by simulation experiments. These preliminary conclusions are helpful to reveal the nature of the proposed structure and solve the technical problem of preventing detonation flame propagation of coal mine gas in large pipelines.
- Open Access
A Novel Method for Gas Turbine Condition Monitoring Based on KPCA and Analysis of Statistics T2 and SPE
Gas turbines are widely used all over the world, in order to ensure the normal operation of gas turbines, it is necessary to monitor the condition of gas turbine and analyze the tested parameters to find the state information contained in parameters. There is a problem in gas turbine condition monitoring that how to locate the fault accurately if failure occurs. To solve the problem, this paper proposes a method to locate the fault of gas turbine components by evaluating the sensitivity of tested parameters to fault. Firstly, the tested parameters are decomposed by the kernel principal component analysis. Then construct the statistics of T2 and SPE in the principal elements space and residual space, respectively. Furthermore, the thresholds of the statistics must be calculated. The influence of tested parameters on faults is analyzed, and the degree of influence is quantified. The fault location can be realized according to the analysis results. The research results show that the proposed method can realize fault diagnosis and location accurately.
Open AccessA Novel Method for Gas Turbine Condition Monitoring Based on KPCA and Analysis of Statistics T2 and SPE
Gas turbines are widely used all over the world, in order to ensure the normal operation of gas turbines, it is necessary to monitor the condition of gas turbine and analyze the tested parameters to find the state information contained in parameters. There is a problem in gas turbine condition monitoring that how to locate the fault accurately if failure occurs. To solve the problem, this paper proposes a method to locate the fault of gas turbine components by evaluating the sensitivity of tested parameters to fault. Firstly, the tested parameters are decomposed by the kernel principal component analysis. Then construct the statistics of T2 and SPE in the principal elements space and residual space, respectively. Furthermore, the thresholds of the statistics must be calculated. The influence of tested parameters on faults is analyzed, and the degree of influence is quantified. The fault location can be realized according to the analysis results. The research results show that the proposed method can realize fault diagnosis and location accurately.