LSLevent Sennaroglu

Levent Sennaroglu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Levent Sennaroglu has a total of 88 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ChatGPT vs. multidisciplinary team decisions in auditory implantation: a concordance analysis of implant type and side selection

    by Yaşar Enez Bilen, Ergin Eroğlu, Yaşar Atay, Levent Sennaroğlu

    Introduction Auditory implantation is a standard rehabilitation strategy for patients with severe hearing loss, and candidacy determination requires a multidisciplinary, multidimensional evaluation. With the increasing clinical use of artificial intelligence–based large language models, ChatGPT has emerged as a potential decision-support tool. This study aimed to evaluate the agreement between multidisciplinary team (MDT) decisions and ChatGPT recommendations in pediatric and adult implant candidates. Methods This retrospective cross-sectional study included 100 consecutive auditory implant candidates (50 pediatric, 50 adult) evaluated at a tertiary referral center. Each case was independently presented to ChatGPT (OpenAI, accessed March 2025) using standardized English prompts. ChatGPT was asked whether implantation was recommended and, if so, which side should be implanted. MDT decisions were used as the reference standard, and agreement between MDT and ChatGPT was analyzed using Cohen’s kappa (κ) coefficient. Results High agreement was observed between MDT and ChatGPT for both implant type (κ = 0.714; p < 0.001) and side of implantation (κ = 0.701; p < 0.001). Subgroup analysis demonstrated higher agreement in pediatric patients (implant type κ = 0.773; side κ = 0.784; p < 0.001) compared to adults (implant type κ = 0.589; side κ = 0.601; p < 0.001). Concordance was also higher in simple cases than in clinically complex cases. Conclusion ChatGPT demonstrated substantial agreement with MDT decisions regarding implant type and side of implantation, with higher concordance in pediatric and simple cases. These findings suggest that ChatGPT may serve as a supportive decision-making tool in structured clinical scenarios; however, multidisciplinary evaluation remains essential in individualized and complex cases.


  • Speech Intelligibility and Spectral Resolution Results in Cochlear Implant Users With and Without Inner Ear Malformations and the Effect of Angular Insertion Depth

    by Merve Ozses, Betul Cicek Cinar, Levent Sennaroglu

    Objective: This study aimed to compare speech perception in noise and spectral resolution between CI users with normal cochlea and those with inner ear malformations (IEMs) and to examine the relationship between angular insertion depth (AID). Design: Prospective cohort. Setting: Cochlear implant (CI) program at a tertiary medical center. Patients: Thirty-seven pediatric CI users participated: 14 with normal cochleae and 23 with IEMs (2 with IP-I, 15 with IP-II, 1 with IP-III, and 5 with CH-III). The normal cochleae group consisted of 3 unilateral CI users, 7 bimodal users, and 4 bilateral users, whereas the IEM group consisted of 6 unilateral CI users, 10 bimodal users, and 7 bilateral users. All participants received MED-EL devices. A total of 48 implanted ears from 37 patients were included. In the IEM group, 18 ears (1 with IP-I, 1 with CH-III, and 16 with IP-II) received the FORM24 electrode, and 10 ears (1 with IP-I, 1 with IP-II, 2 with IP-III, and 6 with CH-III) received the FORM19 electrode. Methods: Speech perception was assessed using the hearing in noise test for children (HINT-C), and spectral resolution was measured using the Spectral-Temporally Modulated Ripple Test (SMRT). AID was determined using postoperative transorbital x-rays. Associations between AID and auditory outcomes were examined using correlation and linear mixed-effects modeling. Results: CI users with normal cochleae had better speech perception signal-to-noise ratio (SNR) in the N Ipsilateral S Front and N Front S Front conditions, whereas CI users with IEMs demonstrated poorer speech perception in noise, requiring more favorable SNRs. There was no significant difference in the N Contralateral S Front condition. CI users with IEMs had lower ripple-density thresholds, indicating reduced spectral resolution. In simple regression analyses, deeper AID was associated with better performance in the Quiet and NIpsilateralSFront conditions and with higher SMRT scores. However, in linear mixed-effects models, group differences remained significant for Quiet, N Ipsilateral S Front and N Front S Front , whereas AID independently influenced only Quiet and N Ipsilateral S Front . No independent effect of AID on SMRT was observed. Conclusions: CI users with IEMs required higher signal-to-noise ratios to understand speech in noise and demonstrated poorer spectral resolution than their CI peers with normal cochleae. Although deeper AID was positively correlated with both spectral-resolution skills and speech perception, its independent contribution to spectral resolution appears limited after adjusting for clinical and demographic factors. These results suggest that cochlear anatomy and electrode insertions have potential clinical roles in auditory outcomes, highlighting the multifactorial nature of performance variability in pediatric CI users.

  • Open Access

    Evaluation of cochlear angular orientation in patients with CHARGE syndrome

    by Ergin Eroğlu, Çağrı Külekçi, Canset Aydın, Levent Sennaroğlu

    Purpose: This study aimed to evaluate cochlear angulation in patients with CHARGE syndrome and compare it with individuals with normal cochlear anatomy. Methods: Eighteen patients with CHARGE syndrome followed for sensorineural hearing loss were retrospectively reviewed and compared with 18 age-matched controls with normal cochlear anatomy. Temporal bone computed tomography (CT) and magnetic resonance imaging were analyzed to assess inner ear malformations and cochlear nerve status. Cochlear angulation was measured on axial CT images by calculating the angle formed between lines passing through the basal turns of both cochleae at the level of the round window. Statistical analyses were performed using chi-square and independent samples t-tests. Results: Cochlear hypoplasia type III was the most common anomaly in the CHARGE group. Cochlear nerves were frequently hypoplastic or absent, whereas all control ears were normal. Mean cochlear angulation was significantly narrower in the CHARGE group compared with controls (94.49° ± 10.02° vs. 114.02° ± 8.17°, p < 0.001). Conclusion: CHARGE syndrome is associated with significantly altered cochlear angulation, which may contribute to surgical challenges during cochlear implantation. Preoperative recognition of this feature may facilitate safer and more effective surgical planning.

  • Open Access

    Histopathology of Inner Ear Malformations: Potential Prognostic Factors and Their Influence in the Decision-Making Between CI and ABI

    by Levent Sennaroglu, Rafael da Costa Monsanto, Daniel J. Lee, Irem Gul Sancak, Michael Mauro Paparella, Sebahattin Cureoglu

    Importance: Histopathological findings are important to guide our decision between cochlear and auditory brainstem implant in inner ear malformations (IEM) with cochlear hypoplasia (CH), incomplete partition (IP), and common cavity. Objective: Cochlear implantation (CI) has variable outcome in IEM. Histopathology of IEM is evaluated to understand the causes of this variation. Design: Evaluation of human temporal bone specimens with IEM. Participants: Twenty temporal bone specimens from 10 donors who had IEMs were evaluated. Main outcome measures: Classification of IEM and analysis of cochlear morphology [inner and outer hair cells, spiral ganglion cells, and cochlear nerve (CN)] to understand the functional outcome of implantation. Results: Among the temporal bones with IEMs, 16 were classified as CH, 2 were IPs type II, and 2 had a normal cochlear anatomy, but absent CNs. The CN was hypoplastic in 3 specimens with CH-III. The nerve was lying adjacent to the bony wall, which would be difficult to demonstrate with current magnetic resonance imaging (MRI). The mean percentage of loss of spiral ganglion cells in CH-III among our specimens was 62%. Some specimens showed asymmetric development, which will play a crucial role in the benefit from CI. Two specimens from the same donor with a fully-developed cochlea demonstrated absent CN. Conclusion: Better MRI sequences are needed to demonstrate the hypoplastic CN adjacent to the wall of the internal auditory canal. Audiological examination is of paramount importance to demonstrate the presence of neural connection between the cochlea and the brainstem. In asymmetric developments between 2 sides, more developed side should be chosen for CI. Depending on the findings cochlear or auditory brainstem implants may be chosen for the contralateral findings. If there is only one implant available, the side with the better developed CN should be picked.

  • COVID-19-Induced Bilateral Sensorineural Hearing Loss in Cogan’s Syndrome: A Case of Successful Cochlear Implantation in a Pediatric Patient

    by Isa Tuncay Batuk, Ozlem Icoz, Merve Ozbal Batuk, Levent Sennaroglu

    Cogan’s syndrome (CS) is a rare autoimmune disorder that can cause profound sensorineural hearing loss by affecting the eyes and inner ears. A case report of a 12-year-old patient with CS who underwent successful cochlear implantation is presented. The patient developed bilateral hearing loss after a COVID-19 infection and showed no improvement with multiple medical therapies. Radiological evaluation revealed round window ossification and decreased fluid intensity in the cochlea and vestibule, consistent with inner ear inflammation and early-stage ossification. Following bilateral simultaneous cochlear implant surgery, the patient exhibited a notable improvement in auditory perception scores immediately after activation. The open-set sentence recognition performance increased from 0% to 93% 3 months after cochlear implantation. This case underscores the potential role of COVID-19 as a trigger for CS and highlights the remarkable efficacy of cochlear implants in rehabilitating hearing loss in pediatric patients with this syndrome.

  • Open Access

    Dose- and Time-Dependent Halofuginone Cytotoxicity in HaCaT Keratinocytes: Implications for Cholesteatoma

    by Burçay Tellioğlu, Esin Akbay Çetin, Handan Sevim Akan, Münir Demir Bajin, Mehmet Ali Onur, Levent Sennaroğlu

    Background and Objectives: Cholesteatomas are chronically progressive keratinizing epithelial lesions that locally destroy tissue and erode bone. Surgery is the primary treatment for cholesteatomas; however, tumor recurrence and complications have prompted the search for more effective medical therapies. Halofuginone (HF) inhibits multiple pathways implicated in cholesteatoma pathogenesis. Therefore, the dose- and time-dependent cytotoxic effects of HF on the spontaneously transformed human adult skin keratinocyte (HaCaT) cell line were investigated, and the IC50 values of HF were determined as a preliminary step in evaluating the potential of using HF as a pharmacological treatment for cholesteatoma.Materials and Methods: An in vitro experiment was conducted using HaCaT cells, which is an immortalized human keratinocyte cell line. Cells were treated with HF at 0.1 μM to 100 μM for 24 and 48 hours. Cell viability was measured via an MTT assay, and the IC50 values were calculated using nonlinear regression analysis.Results: HF treatment substantially dose- and time-dependently reduced HaCaT cell viability. The IC50 values at 24 and 48 hours were 2.74 μM and 0.24 μM, respectively, reflecting a more than ten-fold increase in cytotoxic potency over time. The differences between the treatment groups were significant at both time points (p=0.017 and p=0.001 at 24 and 48 hours, respectively).Conclusions: HF exerts potent cytotoxic effects on keratinocytes, with efficacy increasing with exposure duration. These findings support the further study of HF as a pharmacological agent for modulating epithelial proliferation in cholesteatomas and related disorders.

  • Evaluation of Amplification Systems for Sound Localization and Speech Perception in Single-Sided Deafness: A Comparative Study With Low-Frequency Stimulus

    by Yağız Korkut, Isa Tuncay Batuk, Merve Ozbal Batuk, Levent Sennaroğlu

    Purpose: This study aimed to evaluate the impact of different hearing devices on sound localization and speech perception in individuals with single-sided deafness (SSD). Specifically, the study sought to assess the performance of softband bone-anchored hearing aids (BAHAs) and contralateral routing of signals hearing aids (CROS HA) in various conditions to determine their effectiveness in improving auditory outcomes for SSD patients. Method: Eighteen participants (aged between 20 and 50 years) with SSD underwent tests using softband BAHA, CROS HA, and unaided conditions in a counterbalanced design. Sound localization tests, speech perception in noise assessments, and subjective satisfaction ratings were conducted to measure the effectiveness of the hearing devices. The study employed a single-subject, repeated-measures experimental design to compare the performance of the different devices. Results: The results revealed that softband BAHA significantly improved sound localization, particularly in low-frequency stimulus localization, compared to CROS HA and unaided conditions ( p = .03). Subjective satisfaction scores aligned with objective test outcomes, indicating a preference for softband BAHA. Speech perception in noise performance varied across conditions, with both hearing devices showing benefits in certain scenarios. Conclusions: The findings of this study have important clinical implications for selecting appropriate hearing device options for SSD patients. Softband BAHA demonstrated superior performance in sound localization tasks, as evidenced by the significant improvement observed in the Azimuth Localization Test results. This test measures a central auditory skill—sound localization—by evaluating participants' ability to accurately identify the direction of sound sources. The enhanced performance with softband BAHA in this task suggests that the BAHA device provides the brain with more robust cues for localization when compared with the CROS device. Using suitable hearing devices during rehabilitation for SSD patients is crucial for enhancing auditory outcomes and quality of life in this population. Further research is warranted to address the limitations identified and optimize rehabilitation strategies for individuals with SSD.

  • Evaluating the accuracy and reproducibility of ChatGPT responses in the context of cochlear implantation

    by Ergin Eroğlu, Erim Pamuk, Munir Demir Bajin, Levent Sennaroğlu

    The use of ChatGPT in the field of otolaryngology is increasing; however, there are not enough studies related to cochlear implants. To assess the accuracy and reproducibility of ChatGPT (GPT-4o) responses to questions about cochlear implantation, evaluating its potential role in patient education. A total of 104 questions across five categories (basic, preoperative, surgical, postoperative care, postoperative expectations) were selected from reliable online sources. Each was posed twice to ChatGPT-4o in separate sessions. Responses were graded by two reviewers for accuracy (comprehensive/correct, partially correct, misleading, or incorrect/irrelevant). Reproducibility was assessed based on consistency across sessions. Discrepancies were resolved by a third expert reviewer. Of 104 responses, 84.6% were correct, 5.8% partially correct, 6.7% misleading, and 2.9% incorrect. Reproducibility was 88.4% overall and 100% in the surgery category. No significant differences were found between question categories for accuracy (p = 0.829) or reproducibility (p = 0.348). ChatGPT provided highly accurate and reproducible responses to cochlear implant-related questions, supporting its use as an educational tool. Nonetheless, expert review remains essential for complex or critical topics.


  • Intraoperative impedance and ECAP results in cochlear implant recipients with inner ear malformations and normal cochlear anatomy: a retrospective analysis

    by Merve İkIz Bozsoy, Aysun Parlak Kocabay, Betül Koska, Beyza Demirtaş Yılmaz, Merve Özses, Nizamettin Burak Avcı, Selvet Akkaplan, Zeynep Budak Ateş, Betül Çiçek Çınar, Mehmet Yaralı, et al.

    The intraoperative measurements are essential steps in cochlear implant (CI) surgery for confirming correct electrode placement. To examine the intraoperative impedance and electrically evoked action potential (ECAP) measurement results of cochlear implant (CI) users with normal cochlear anatomy (NCA) and to compare them with CI users with inner ear malformations (IEM). This retrospective study included intraoperative data of 300 ears from 258 individuals using Medel® and Cochlear (Nucleus®) CI devices. Impedance values differed through all regions, and that differences in ECAPs results mainly stemmed from the basal region in Cochlear users, when comparing the impedance values and ECAPs recording prevalence between the NCA and IEM groups, it was observed that there was no significant difference in the impedance values across the intracochlear regions of the groups (apical; p = .26, middle; p = .12, basal; p = .99). However, it was found that the prevalence of measurable ECAPs in all intracochlear regions of the NCA group was higher than the IEM group (p = .000). The robustness of cochlear structures is a crucial factor in the recording of ECAPs. Furthermore, findings in the IEM group demonstrated that proper placement of intracochlear electrodes did not guarantee effective auditory nerve stimulation.