Heinrich Rau
Research Subjects
Heinrich Rau has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Ströhle
Department of Psychiatry and Psychotherapy, Campus Charité Mitte, Charité – Universitätsmedizin Berlin, Berlin, Germany
1 shared publication - Anne Dyer
ZISG Mannheim, Central Institute of Mental Health, J 5, 68159, Mannheim, Germany
1 shared publication - Antje Krüger-Gottschalk
University of Munster
1 shared publication - Christine Knaevelsrud
Freie Universität Berlin
1 shared publication - Gerd-Dieter Willmund
Center for Military Mental Health, Military Hospital Berlin, Berlin, Germany
1 shared publication - Ingo Schäfer
Zentrum für Interdisziplinäre Suchtforschung (ZIS) der Universität Hamburg, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 29 November 2018
- Published by Elsevier in Military Medical Research
- Vol. 5 (1) , 40
Stigma and its impact on the families of former soldiers of the German Armed Forces: an exploratory study
- 29 November 2018
- Published by Elsevier in Military Medical Research
- Vol. 5 (1) , 40
Open AccessStigma and its impact on the families of former soldiers of the German Armed Forces: an exploratory study
- Top Cited PapersOpen Access
- 28 November 2017
- Published by Springer Nature in BMC Psychiatry
- Vol. 17 (1) , 1-9
The German version of the Posttraumatic Stress Disorder Checklist for DSM-5 (PCL-5): psychometric properties and diagnostic utility
The Posttraumatic Stress Disorder (PTSD) Checklist (PCL, now PCL-5) has recently been revised to reflect the new diagnostic criteria of the disorder. A clinical sample of trauma-exposed individuals (N = 352) was assessed with the Clinician Administered PTSD Scale for DSM-5 (CAPS-5) and the PCL-5. Internal consistencies and test-retest reliability were computed. To investigate diagnostic accuracy, we calculated receiver operating curves. Confirmatory factor analyses (CFA) were performed to analyze the structural validity. Results showed high internal consistency (α = .95), high test-retest reliability (r = .91) and a high correlation with the total severity score of the CAPS-5, r = .77. In addition, the recommended cutoff of 33 on the PCL-5 showed high diagnostic accuracy when compared to the diagnosis established by the CAPS-5. CFAs comparing the DSM-5 model with alternative models (the three-factor solution, the dysphoria, anhedonia, externalizing behavior and hybrid model) to account for the structural validity of the PCL-5 remained inconclusive. Overall, the findings show that the German PCL-5 is a reliable instrument with good diagnostic accuracy. However, more research evaluating the underlying factor structure is needed.
- 28 November 2017
- Published by Springer Nature in BMC Psychiatry
- Vol. 17 (1) , 1-9
Top Cited PapersOpen AccessThe German version of the Posttraumatic Stress Disorder Checklist for DSM-5 (PCL-5): psychometric properties and diagnostic utility
The Posttraumatic Stress Disorder (PTSD) Checklist (PCL, now PCL-5) has recently been revised to reflect the new diagnostic criteria of the disorder. A clinical sample of trauma-exposed individuals (N = 352) was assessed with the Clinician Administered PTSD Scale for DSM-5 (CAPS-5) and the PCL-5. Internal consistencies and test-retest reliability were computed. To investigate diagnostic accuracy, we calculated receiver operating curves. Confirmatory factor analyses (CFA) were performed to analyze the structural validity. Results showed high internal consistency (α = .95), high test-retest reliability (r = .91) and a high correlation with the total severity score of the CAPS-5, r = .77. In addition, the recommended cutoff of 33 on the PCL-5 showed high diagnostic accuracy when compared to the diagnosis established by the CAPS-5. CFAs comparing the DSM-5 model with alternative models (the three-factor solution, the dysphoria, anhedonia, externalizing behavior and hybrid model) to account for the structural validity of the PCL-5 remained inconclusive. Overall, the findings show that the German PCL-5 is a reliable instrument with good diagnostic accuracy. However, more research evaluating the underlying factor structure is needed.