Qingtang Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qingtang Zhu has a total of 175 co-authors. Here are the top co-authors by number of shared publications:
Shuai Qiu
Guangdong Engineering Technology Research Centre for Peripheral Nerve Tissue, Department of Orthopaedic and Microsurgery, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong Province, China
9 shared publicationsXiaolin Liu
Department of Microsurgery, Orthopedic Trauma and Hand Surgery, The First Affiliated Hospital, Sun Yat-sen University , Guangzhou 510080
8 shared publications- Jian Qi
Department of Microsurgery, Trauma and Hand Surgery, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 51080, China; Guangdong Province Engineering Laboratory for Soft Tissue Biofabrication, Sun-Yat-sen University, Guangzhou 510080, China; Guangdong Provincial Key Laboratory for Orthopedics and Traumatology, Guangzhou 510080, China
7 shared publications - Xiaolin Liu
Department of Microsurgery, Orthopedic Trauma and Hand Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
7 shared publications - Jiantao Yang
Department of Microsurgery, Orthopedic Trauma and Hand Surgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
6 shared publications Jingyuan Fan
6 shared publications
Latest Publications
- 23 October 2026
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 124, 110-118
Robot-assisted (super) microsurgery: A randomized in vivo preclinical trial for microvascular anastomosis
- 23 October 2026
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 124, 110-118
Robot-assisted (super) microsurgery: A randomized in vivo preclinical trial for microvascular anastomosis
- Open Access
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e91061
Mapping the Evolving AI Preferences and Care Needs in Orthopedic Transitional Care From Hospitals to Home: Cross-Sectional Study
Background: Enhanced recovery after surgery protocols have shortened orthopedic hospital stays but have shifted rehabilitation and safety-monitoring tasks to patients and families after discharge. In this study, AI refers to patient-facing digital systems for orthopedic transitional care, including large language model chatbots, computer vision or platform-based monitoring tools, and wearable sensor–enabled systems for education, rehabilitation guidance, motion correction, and risk alerts. However, patient-reported preferences for different AI-supported functions across the hospital-to-home transition remain underexplored. Objective: This study aimed to map the evolution of care needs from hospital to home recovery and to identify specific preferences and factors associated with the willingness to use AI systems in orthopedic transitional care. Methods: We conducted a multicenter cross-sectional survey among patients recovering from orthopedic surgery in 33 Guangdong hospitals, China. Of the 860 submitted questionnaires, 752 responses were included after prespecified quality control, including exclusion of responses completed in 180 seconds or less based on pilot-informed screening. Participants rated standardized function-based AI descriptions rather than a specific prototype or live tool. The data covered demographic and clinical characteristics, task priorities across care phases, perceived transitional care challenges, and stated willingness to use AI. The survey was informed by the technology acceptance model, although perceived usefulness, perceived ease of use, and attitude toward use were not directly measured. Exploratory factor analysis was used to examine perceived challenges. Descriptive mapping summarized care needs and AI function preferences, and multivariable logistic regression explored factors associated with willingness. Results: Most respondents reported a willingness to use AI (604/752, 80.3%). Care priorities varied by phase: inpatient priorities were more often related to information acquisition and care instruction, whereas home-stage priorities more often involved functional safety, rehabilitation guidance, motion correction, and risk alerts. Exploratory factor analysis identified 3 perceived challenge dimensions: home rehabilitation self-management barriers, lack of professional support, and symptom uncertainty. In adjusted exploratory analysis, willingness to use AI was associated with older age (adjusted odds ratio [aOR] 1.02, 95% CI 1.00‐1.03), comorbidities (aOR 1.72, 95% CI 1.09‐2.69), later rehabilitation stage (aOR 1.28, 95% CI 1.01‐1.62), and urban residence (aOR 1.85, 95% CI 1.14‐3.01). Unmarried, divorced, or widowed status was associated with lower willingness than married status (aOR 0.59, 95% CI 0.39‐0.89). Physical disability and self-care ability were not independently associated with willingness after adjustment. Conclusions: In this hospital-based convenience sample, most respondents were willing to use AI, and their stated priorities shifted from information support during hospitalization to functional safety and rehabilitation support after discharge. The associated factors should be interpreted as exploratory associations rather than causal determinants. Because participants evaluated function-based AI descriptions rather than actual AI tools, these findings can inform future prototype development and real-world evaluation, particularly around usability, trust, privacy, digital accessibility, and clinician oversight.
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e91061
Open AccessMapping the Evolving AI Preferences and Care Needs in Orthopedic Transitional Care From Hospitals to Home: Cross-Sectional Study
Background: Enhanced recovery after surgery protocols have shortened orthopedic hospital stays but have shifted rehabilitation and safety-monitoring tasks to patients and families after discharge. In this study, AI refers to patient-facing digital systems for orthopedic transitional care, including large language model chatbots, computer vision or platform-based monitoring tools, and wearable sensor–enabled systems for education, rehabilitation guidance, motion correction, and risk alerts. However, patient-reported preferences for different AI-supported functions across the hospital-to-home transition remain underexplored. Objective: This study aimed to map the evolution of care needs from hospital to home recovery and to identify specific preferences and factors associated with the willingness to use AI systems in orthopedic transitional care. Methods: We conducted a multicenter cross-sectional survey among patients recovering from orthopedic surgery in 33 Guangdong hospitals, China. Of the 860 submitted questionnaires, 752 responses were included after prespecified quality control, including exclusion of responses completed in 180 seconds or less based on pilot-informed screening. Participants rated standardized function-based AI descriptions rather than a specific prototype or live tool. The data covered demographic and clinical characteristics, task priorities across care phases, perceived transitional care challenges, and stated willingness to use AI. The survey was informed by the technology acceptance model, although perceived usefulness, perceived ease of use, and attitude toward use were not directly measured. Exploratory factor analysis was used to examine perceived challenges. Descriptive mapping summarized care needs and AI function preferences, and multivariable logistic regression explored factors associated with willingness. Results: Most respondents reported a willingness to use AI (604/752, 80.3%). Care priorities varied by phase: inpatient priorities were more often related to information acquisition and care instruction, whereas home-stage priorities more often involved functional safety, rehabilitation guidance, motion correction, and risk alerts. Exploratory factor analysis identified 3 perceived challenge dimensions: home rehabilitation self-management barriers, lack of professional support, and symptom uncertainty. In adjusted exploratory analysis, willingness to use AI was associated with older age (adjusted odds ratio [aOR] 1.02, 95% CI 1.00‐1.03), comorbidities (aOR 1.72, 95% CI 1.09‐2.69), later rehabilitation stage (aOR 1.28, 95% CI 1.01‐1.62), and urban residence (aOR 1.85, 95% CI 1.14‐3.01). Unmarried, divorced, or widowed status was associated with lower willingness than married status (aOR 0.59, 95% CI 0.39‐0.89). Physical disability and self-care ability were not independently associated with willingness after adjustment. Conclusions: In this hospital-based convenience sample, most respondents were willing to use AI, and their stated priorities shifted from information support during hospitalization to functional safety and rehabilitation support after discharge. The associated factors should be interpreted as exploratory associations rather than causal determinants. Because participants evaluated function-based AI descriptions rather than actual AI tools, these findings can inform future prototype development and real-world evaluation, particularly around usability, trust, privacy, digital accessibility, and clinician oversight.
- Open Access
- 21 July 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
A large 4 K dataset of supermicrosurgical anastomosis at the 0.2 mm scale
Supermicrosurgery, involving vessels smaller than 0.8 mm, is an important emerging field in reconstructive surgery. Its development is limited by the lack of suitable training resources and the current performance of microsurgical robotic systems. Existing robots provide limited intelligent assistance, and their anastomosis procedures are significantly slower than manual techniques. Here, we present the Microsurgical Silicone Tube Anastomosis dataset (MSTA), a large-scale 4 K video dataset of 0.2-mm silicone tube anastomosis procedures. The dataset includes 452 procedures performed by 571 operators from 158 hospitals across 28 provinces in China, with a total of 40.77 hours of 4 K video (3,840 × 2,160 pixels). All procedures were performed using standardized microsurgical instruments and imaging settings to ensure consistency and comparability. The participants represented a wide range of experience levels, with completion times ranging from 125 to 600 seconds, providing a broad spectrum of technical performance for analysis. Each procedure is accompanied by quantitative metadata, including completion time and expert-assessed performance scores based on predefined criteria. These data enable objective assessment of technical proficiency and analysis of performance-related factors. In addition, the dataset contains 47,452 segmentation annotation surgical frames, supporting computer vision studies. The MSTA dataset addresses the current gap in supermicrosurgical training data, and supports both surgical-robotics development and human training via objective performance assessment. Its scale and standardized design provide a reliable basis for building intelligent assistance systems and establishing benchmarks for skill evaluation in supermicrosurgery.
- 21 July 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
Open AccessA large 4 K dataset of supermicrosurgical anastomosis at the 0.2 mm scale
Supermicrosurgery, involving vessels smaller than 0.8 mm, is an important emerging field in reconstructive surgery. Its development is limited by the lack of suitable training resources and the current performance of microsurgical robotic systems. Existing robots provide limited intelligent assistance, and their anastomosis procedures are significantly slower than manual techniques. Here, we present the Microsurgical Silicone Tube Anastomosis dataset (MSTA), a large-scale 4 K video dataset of 0.2-mm silicone tube anastomosis procedures. The dataset includes 452 procedures performed by 571 operators from 158 hospitals across 28 provinces in China, with a total of 40.77 hours of 4 K video (3,840 × 2,160 pixels). All procedures were performed using standardized microsurgical instruments and imaging settings to ensure consistency and comparability. The participants represented a wide range of experience levels, with completion times ranging from 125 to 600 seconds, providing a broad spectrum of technical performance for analysis. Each procedure is accompanied by quantitative metadata, including completion time and expert-assessed performance scores based on predefined criteria. These data enable objective assessment of technical proficiency and analysis of performance-related factors. In addition, the dataset contains 47,452 segmentation annotation surgical frames, supporting computer vision studies. The MSTA dataset addresses the current gap in supermicrosurgical training data, and supports both surgical-robotics development and human training via objective performance assessment. Its scale and standardized design provide a reliable basis for building intelligent assistance systems and establishing benchmarks for skill evaluation in supermicrosurgery.
- Open Access
- 27 February 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1758496
Targeted muscle reinnervation attenuates neuropathic pain and neuroma development in a rat model of tibial nerve transection
Background: Peripheral nerve injuries often lead to painful neuroma formation and chronic neuropathic pain, and the optimal surgical strategy for prevention remains debated. Targeted muscle reinnervation (TMR), regenerative peripheral nerve interfaces (RPNI), and nerve-in-muscle implantation (NIM) are surgical techniques developed to mitigate neuroma-related pain, but their relative efficacy has not been compared systematically. This preclinical study compared TMR, NIM, and two RPNI variants in a rat tibial nerve transection model to identify which approach best reduces neuroma formation and pain. Methods: Sprague-Dawley rats underwent right tibial nerve transection and were randomized into five groups: control (no repair), NIM, W-RPNI (wrapped RPNI), E-RPNI (embedded RPNI), or TMR. Behavioral outcomes including gait analysis (CatWalk), mechanical hypersensitivity (von Frey test), thermal hyperalgesia (Hargreaves test), and neuroma tenderness were assessed over 12 weeks. At week 12, distal nerve stumps and L4–L5 dorsal root ganglia (DRG) were harvested for histological evaluation, immunohistochemistry/immunofluorescence, and molecular analyses (qRT-PCR and Western blot) targeting pain- and inflammation-related biomarkers. Results: By 12 weeks, TMR-treated rats showed the most robust improvements, including significantly longer stance duration, larger paw contact area, near-baseline withdrawal thresholds, and minimal neuroma tenderness, whereas untreated controls developed gross neuromas and persistent hypersensitivity. TMR also preserved organized nerve architecture with orderly axonal regeneration and minimal collagen I/III fibrosis at the stump. Molecular assays confirmed that TMR markedly attenuated nociceptive and inflammatory signaling, with TMR rats exhibiting the lowest expression of pain-related mediators (c-Fos, TRPA1, TRPV1, CGRP, NPY, BDNF) and pro-inflammatory/fibrotic markers (galectin, α-SMA, IL-1β, TNF-α, TGF-β) in nerve and DRG tissues. Conversely, the anti-inflammatory cytokine IL-10 and axonal ion pump subunits ATP1A2/ATP2B1 were significantly upregulated with TMR. Outcomes for the two RPNI groups were similar to each other and generally intermediate between TMR and control. Conclusion: TMR was superior to RPNI variants and NIM in preventing neuroma formation and alleviating neuropathic pain in this animal model. These findings support TMR as a promising surgical strategy to mitigate post-amputation neuroma pain.
- 27 February 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1758496
Open AccessTargeted muscle reinnervation attenuates neuropathic pain and neuroma development in a rat model of tibial nerve transection
Background: Peripheral nerve injuries often lead to painful neuroma formation and chronic neuropathic pain, and the optimal surgical strategy for prevention remains debated. Targeted muscle reinnervation (TMR), regenerative peripheral nerve interfaces (RPNI), and nerve-in-muscle implantation (NIM) are surgical techniques developed to mitigate neuroma-related pain, but their relative efficacy has not been compared systematically. This preclinical study compared TMR, NIM, and two RPNI variants in a rat tibial nerve transection model to identify which approach best reduces neuroma formation and pain. Methods: Sprague-Dawley rats underwent right tibial nerve transection and were randomized into five groups: control (no repair), NIM, W-RPNI (wrapped RPNI), E-RPNI (embedded RPNI), or TMR. Behavioral outcomes including gait analysis (CatWalk), mechanical hypersensitivity (von Frey test), thermal hyperalgesia (Hargreaves test), and neuroma tenderness were assessed over 12 weeks. At week 12, distal nerve stumps and L4–L5 dorsal root ganglia (DRG) were harvested for histological evaluation, immunohistochemistry/immunofluorescence, and molecular analyses (qRT-PCR and Western blot) targeting pain- and inflammation-related biomarkers. Results: By 12 weeks, TMR-treated rats showed the most robust improvements, including significantly longer stance duration, larger paw contact area, near-baseline withdrawal thresholds, and minimal neuroma tenderness, whereas untreated controls developed gross neuromas and persistent hypersensitivity. TMR also preserved organized nerve architecture with orderly axonal regeneration and minimal collagen I/III fibrosis at the stump. Molecular assays confirmed that TMR markedly attenuated nociceptive and inflammatory signaling, with TMR rats exhibiting the lowest expression of pain-related mediators (c-Fos, TRPA1, TRPV1, CGRP, NPY, BDNF) and pro-inflammatory/fibrotic markers (galectin, α-SMA, IL-1β, TNF-α, TGF-β) in nerve and DRG tissues. Conversely, the anti-inflammatory cytokine IL-10 and axonal ion pump subunits ATP1A2/ATP2B1 were significantly upregulated with TMR. Outcomes for the two RPNI groups were similar to each other and generally intermediate between TMR and control. Conclusion: TMR was superior to RPNI variants and NIM in preventing neuroma formation and alleviating neuropathic pain in this animal model. These findings support TMR as a promising surgical strategy to mitigate post-amputation neuroma pain.
- Open Access
- 22 January 2026
- Published by Oxford University Press (OUP) in Regenerative Biomaterials
- Vol. 13
Acellular nerve perineurium repairs peripheral nerve injuries in a rat model via ECM-mediated barrier and optimization of the regenerative microenvironment
Building upon the clinically established platform of acellular nerve allografts (ANAs), we developed an advanced derivative: acellular nerve perineurium (ANP) grafts. These grafts are characterized by their preservation of the native perineurial barrier architecture and a unique extracellular matrix (ECM) composition, distinct from the endoneurial basement membrane. This distinctive ECM profile endows ANPs with significantly enhanced barrier integrity and robust neuroprotective properties. In vitro evaluations confirmed that ANP provides a highly favorable substrate, effectively supporting the adhesion and active proliferation of dorsal root ganglion neurons. In a rat model of sciatic nerve transection, ANP grafts demonstrated remarkable therapeutic efficacy. They markedly inhibited the deposition of chondroitin sulfate proteoglycans (CSPGs) at the repair site, thereby preventing traumatic neuroma formation. Furthermore, ANP treatment resulted in a doubling of regenerated axon density and a significant increase in target muscle action potential amplitude. Behavioral recovery in ANP-treated animals approached the functional levels observed in crush-injury controls. Multiomics analyses provided mechanistic insight, revealing that ANP-mediated repair activates multiple pro-regenerative signaling pathways. These collective findings position ANP grafts as a highly promising and clinically translatable biomaterial strategy for improving functional outcomes in peripheral nerve repair.
- 22 January 2026
- Published by Oxford University Press (OUP) in Regenerative Biomaterials
- Vol. 13
Open AccessAcellular nerve perineurium repairs peripheral nerve injuries in a rat model via ECM-mediated barrier and optimization of the regenerative microenvironment
Building upon the clinically established platform of acellular nerve allografts (ANAs), we developed an advanced derivative: acellular nerve perineurium (ANP) grafts. These grafts are characterized by their preservation of the native perineurial barrier architecture and a unique extracellular matrix (ECM) composition, distinct from the endoneurial basement membrane. This distinctive ECM profile endows ANPs with significantly enhanced barrier integrity and robust neuroprotective properties. In vitro evaluations confirmed that ANP provides a highly favorable substrate, effectively supporting the adhesion and active proliferation of dorsal root ganglion neurons. In a rat model of sciatic nerve transection, ANP grafts demonstrated remarkable therapeutic efficacy. They markedly inhibited the deposition of chondroitin sulfate proteoglycans (CSPGs) at the repair site, thereby preventing traumatic neuroma formation. Furthermore, ANP treatment resulted in a doubling of regenerated axon density and a significant increase in target muscle action potential amplitude. Behavioral recovery in ANP-treated animals approached the functional levels observed in crush-injury controls. Multiomics analyses provided mechanistic insight, revealing that ANP-mediated repair activates multiple pro-regenerative signaling pathways. These collective findings position ANP grafts as a highly promising and clinically translatable biomaterial strategy for improving functional outcomes in peripheral nerve repair.
- 11 September 2025
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 19 (13) , 1-12
MTFT: Multimodal Temporal Fusion Transformer for 3D Human Pose and Shape Estimation
- 11 September 2025
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 19 (13) , 1-12
MTFT: Multimodal Temporal Fusion Transformer for 3D Human Pose and Shape Estimation
- Open Access
- 3 September 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27 (1) , e63308
The Mobile Constant, a Self-Reported Method for Shoulder Function Evaluation: Development and Validation Study
Background: Shoulder pain is a highly prevalent musculoskeletal disorder that severely compromises patients’ quality of life. The Constant-Murley Scale (CMS) is a well-established method for shoulder function evaluation. However, the necessity of clinician involvement constrains its utility in continuous monitoring. Recent improvements in human pose estimation and inertial sensors provide possibilities for automated functional assessment. Objective: This study introduces an automated CMS assessment system that can provide objective measuring results using movement images and inertial sensor data (Mobile Constant) and aims to evaluate its reliability by comparison with standard results from human raters. Methods: The Mobile Constant system integrated subjective symptom questionnaires, range-of-motion analysis, and strength assessment. Patients presenting with shoulder concerns were enrolled consecutively, with movement images and inertial sensor data collected from each participant. The dataset was structured as follows: patients recruited from February to November 2022 at our hospital formed the training set, those enrolled between December 2022 and February 2023 served as the internal validation set, and patients recruited from April to July 2025 at an independent hospital constituted the external validation set. Gold standard assessments were determined independently by 2 raters using standardized protocols. Six machine learning models (logistic regression, k-nearest neighbors, decision tree, support vector machine, random forest, and adaptive boosting) were developed. The reliability of the system was determined by comparison with human raters using differences, Cohen κ coefficients, and intraclass correlation coefficients (ICCs). Agreement across human raters was also evaluated by comparison between 4 independent clinicians. Results: Data from 141 patients with shoulder pain and stiffness were collected (training set: n=83, 58.9%; internal validation set: n=28; 19.9%; external validation set: n=30, 21.3%). For range-of-motion analysis, the Mobile Constant system showed fair to substantial reliability, achieving κ coefficients ranging from 0.498 to 0.819 and ICCs ranging from 0.898 to 0.956 in the internal validation set. In the external validation set, κ coefficients ranged from 0.198 to 0.699, and ICCs ranged from 0.584 to 0.922. For abduction strength assessment, the k-nearest neighbors model demonstrated substantial reliability, yielding a κ coefficient of 0.707 and an ICC of 0.759 in internal validation and higher agreement in external validation (κ=0.809; ICC=0.906). Conclusions: The self-reported method for shoulder function evaluation demonstrated substantial agreement with experienced human raters. The proposed system enabled reliable patient-conducted assessment using mobile phone–integrated cameras and inertial sensors and exhibited strong potential for remote monitoring.
- 3 September 2025
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 27 (1) , e63308
Open AccessThe Mobile Constant, a Self-Reported Method for Shoulder Function Evaluation: Development and Validation Study
Background: Shoulder pain is a highly prevalent musculoskeletal disorder that severely compromises patients’ quality of life. The Constant-Murley Scale (CMS) is a well-established method for shoulder function evaluation. However, the necessity of clinician involvement constrains its utility in continuous monitoring. Recent improvements in human pose estimation and inertial sensors provide possibilities for automated functional assessment. Objective: This study introduces an automated CMS assessment system that can provide objective measuring results using movement images and inertial sensor data (Mobile Constant) and aims to evaluate its reliability by comparison with standard results from human raters. Methods: The Mobile Constant system integrated subjective symptom questionnaires, range-of-motion analysis, and strength assessment. Patients presenting with shoulder concerns were enrolled consecutively, with movement images and inertial sensor data collected from each participant. The dataset was structured as follows: patients recruited from February to November 2022 at our hospital formed the training set, those enrolled between December 2022 and February 2023 served as the internal validation set, and patients recruited from April to July 2025 at an independent hospital constituted the external validation set. Gold standard assessments were determined independently by 2 raters using standardized protocols. Six machine learning models (logistic regression, k-nearest neighbors, decision tree, support vector machine, random forest, and adaptive boosting) were developed. The reliability of the system was determined by comparison with human raters using differences, Cohen κ coefficients, and intraclass correlation coefficients (ICCs). Agreement across human raters was also evaluated by comparison between 4 independent clinicians. Results: Data from 141 patients with shoulder pain and stiffness were collected (training set: n=83, 58.9%; internal validation set: n=28; 19.9%; external validation set: n=30, 21.3%). For range-of-motion analysis, the Mobile Constant system showed fair to substantial reliability, achieving κ coefficients ranging from 0.498 to 0.819 and ICCs ranging from 0.898 to 0.956 in the internal validation set. In the external validation set, κ coefficients ranged from 0.198 to 0.699, and ICCs ranged from 0.584 to 0.922. For abduction strength assessment, the k-nearest neighbors model demonstrated substantial reliability, yielding a κ coefficient of 0.707 and an ICC of 0.759 in internal validation and higher agreement in external validation (κ=0.809; ICC=0.906). Conclusions: The self-reported method for shoulder function evaluation demonstrated substantial agreement with experienced human raters. The proposed system enabled reliable patient-conducted assessment using mobile phone–integrated cameras and inertial sensors and exhibited strong potential for remote monitoring.
- Open Access
- 21 June 2024
- Published by JMIR Publications Inc. in JMIR Preprints
The Mobile Constant, a Self-Reported Method for Shoulder Function Evaluation: Development and Validation Study (Preprint)
BACKGROUND Shoulder pain is a highly prevalent musculoskeletal disorder that severely compromises patients’ quality of life. The Constant-Murley Scale (CMS) is a well-established method for shoulder function evaluation. However, the necessity of clinician involvement constrains its utility in continuous monitoring. Recent improvements in human pose estimation and inertial sensors provide possibilities for automated functional assessment. OBJECTIVE This study introduces an automated CMS assessment system that can provide objective measuring results using movement images and inertial sensor data (Mobile Constant) and aims to evaluate its reliability by comparison with standard results from human raters. METHODS The Mobile Constant system integrated subjective symptom questionnaires, range-of-motion analysis, and strength assessment. Patients presenting with shoulder concerns were enrolled consecutively, with movement images and inertial sensor data collected from each participant. The dataset was structured as follows: patients recruited from February to November 2022 at our hospital formed the training set, those enrolled between December 2022 and February 2023 served as the internal validation set, and patients recruited from April to July 2025 at an independent hospital constituted the external validation set. Gold standard assessments were determined independently by 2 raters using standardized protocols. Six machine learning models (logistic regression, k-nearest neighbors, decision tree, support vector machine, random forest, and adaptive boosting) were developed. The reliability of the system was determined by comparison with human raters using differences, Cohen κ coefficients, and intraclass correlation coefficients (ICCs). Agreement across human raters was also evaluated by comparison between 4 independent clinicians. RESULTS Data from 141 patients with shoulder pain and stiffness were collected (training set: n=83, 58.9%; internal validation set: n=28; 19.9%; external validation set: n=30, 21.3%). For range-of-motion analysis, the Mobile Constant system showed fair to substantial reliability, achieving κ coefficients ranging from 0.498 to 0.819 and ICCs ranging from 0.898 to 0.956 in the internal validation set. In the external validation set, κ coefficients ranged from 0.198 to 0.699, and ICCs ranged from 0.584 to 0.922. For abduction strength assessment, the k-nearest neighbors model demonstrated substantial reliability, yielding a κ coefficient of 0.707 and an ICC of 0.759 in internal validation and higher agreement in external validation (κ=0.809; ICC=0.906). CONCLUSIONS The self-reported method for shoulder function evaluation demonstrated substantial agreement with experienced human raters. The proposed system enabled reliable patient-conducted assessment using mobile phone–integrated cameras and inertial sensors and exhibited strong potential for remote monitoring.
- 21 June 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessThe Mobile Constant, a Self-Reported Method for Shoulder Function Evaluation: Development and Validation Study (Preprint)
BACKGROUND Shoulder pain is a highly prevalent musculoskeletal disorder that severely compromises patients’ quality of life. The Constant-Murley Scale (CMS) is a well-established method for shoulder function evaluation. However, the necessity of clinician involvement constrains its utility in continuous monitoring. Recent improvements in human pose estimation and inertial sensors provide possibilities for automated functional assessment. OBJECTIVE This study introduces an automated CMS assessment system that can provide objective measuring results using movement images and inertial sensor data (Mobile Constant) and aims to evaluate its reliability by comparison with standard results from human raters. METHODS The Mobile Constant system integrated subjective symptom questionnaires, range-of-motion analysis, and strength assessment. Patients presenting with shoulder concerns were enrolled consecutively, with movement images and inertial sensor data collected from each participant. The dataset was structured as follows: patients recruited from February to November 2022 at our hospital formed the training set, those enrolled between December 2022 and February 2023 served as the internal validation set, and patients recruited from April to July 2025 at an independent hospital constituted the external validation set. Gold standard assessments were determined independently by 2 raters using standardized protocols. Six machine learning models (logistic regression, k-nearest neighbors, decision tree, support vector machine, random forest, and adaptive boosting) were developed. The reliability of the system was determined by comparison with human raters using differences, Cohen κ coefficients, and intraclass correlation coefficients (ICCs). Agreement across human raters was also evaluated by comparison between 4 independent clinicians. RESULTS Data from 141 patients with shoulder pain and stiffness were collected (training set: n=83, 58.9%; internal validation set: n=28; 19.9%; external validation set: n=30, 21.3%). For range-of-motion analysis, the Mobile Constant system showed fair to substantial reliability, achieving κ coefficients ranging from 0.498 to 0.819 and ICCs ranging from 0.898 to 0.956 in the internal validation set. In the external validation set, κ coefficients ranged from 0.198 to 0.699, and ICCs ranged from 0.584 to 0.922. For abduction strength assessment, the k-nearest neighbors model demonstrated substantial reliability, yielding a κ coefficient of 0.707 and an ICC of 0.759 in internal validation and higher agreement in external validation (κ=0.809; ICC=0.906). CONCLUSIONS The self-reported method for shoulder function evaluation demonstrated substantial agreement with experienced human raters. The proposed system enabled reliable patient-conducted assessment using mobile phone–integrated cameras and inertial sensors and exhibited strong potential for remote monitoring.
- 31 May 2024
- Published by Elsevier in Experimental Cell Research
- Vol. 439 (2) , 114111
In vitro modeling of skeletal muscle ischemia-reperfusion injury based on sphere differentiation culture from human pluripotent stem cells
- 31 May 2024
- Published by Elsevier in Experimental Cell Research
- Vol. 439 (2) , 114111
In vitro modeling of skeletal muscle ischemia-reperfusion injury based on sphere differentiation culture from human pluripotent stem cells