Tucker Evans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tucker Evans has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Johan A. Frenje
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
15 shared publications - Maria Gatu Johnson
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
14 shared publications - Benjamin L. Reichelt
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
12 shared publications - Jacob A. Pearcy
Massachusetts Institute of Technology
12 shared publications - Richard D. Petrasso
Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139
12 shared publications - Skylar G. Dannhoff
Massachusetts Institute of Technology , Cambridge, Massachusetts 02139
12 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Evaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessEvaluation of the high-performance TechnoTrak CR-39 for detection of 1–9 MeV fusion protons
In this paper, the MeV-proton response of a high-sensitivity, low-noise CR-39 nuclear track detector, TechnoTrak, produced by the Chiyoda Technol Corporation, is evaluated. Plastic CR-39 nuclear track detectors are commonly used for precise time-integrated measurement of charged particles. Such measurements are crucial for diagnosing inertial confinement fusion (ICF) and high energy density (HED) experiments at the Omega Laser Facility, the Z Pulsed Power Facility, and the National Ignition Facility. The response of TechnoTrak CR-39 detectors was tested with protons produced from DD and D3He fusion reactions at the MIT linear ion accelerator. The results indicate that TechnoTrak CR-39 detectors exhibit high detection efficiency over a wide proton energy range (∼1−5 MeV), remain sensitive to protons up to ∼9 MeV, and have lower intrinsic noise than widely used TASTRAKTM CR-39 produced by Track Analysis Systems Ltd. This wide detectable energy range and low noise floor may benefit future HED and ICF experiments requiring low background levels and broad proton energy sensitivity.
- Open Access
- 29 September 2026
- Published by American Physical Society (APS) in Physical Review E
- Vol. 114 (3) , 035216
Inference of thermodynamic conditions in convergent high-energy-density-physics experiments
Laser-driven spherical implosion experiments create some of the most extreme states of matter accessible in the laboratory. However, experimental observables in implosion experiments are highly integrated, meaning that measurements cannot be straightforwardly inverted to characterize the thermodynamic states or material properties in the implosion. Thus, to understand the extreme states of matter typical of implosions, a new generation of experiments and analyses are needed that leverage modern statistical tools. This work presents a comprehensive Bayesian inference framework that enables the analysis of integrated x-ray self-emission measurements from laser-driven implosions at the OMEGA laser, producing equation-of-state data (pressure, density, and temperature) between 0.1 to 1.5 Gbar. The model is benchmarked against synthetic data from radiation-hydrodynamics simulations, and opens avenues for producing quantitative constraints on physical models relevant to dense astrophysical and laboratory fusion plasmas.
- 29 September 2026
- Published by American Physical Society (APS) in Physical Review E
- Vol. 114 (3) , 035216
Open AccessInference of thermodynamic conditions in convergent high-energy-density-physics experiments
Laser-driven spherical implosion experiments create some of the most extreme states of matter accessible in the laboratory. However, experimental observables in implosion experiments are highly integrated, meaning that measurements cannot be straightforwardly inverted to characterize the thermodynamic states or material properties in the implosion. Thus, to understand the extreme states of matter typical of implosions, a new generation of experiments and analyses are needed that leverage modern statistical tools. This work presents a comprehensive Bayesian inference framework that enables the analysis of integrated x-ray self-emission measurements from laser-driven implosions at the OMEGA laser, producing equation-of-state data (pressure, density, and temperature) between 0.1 to 1.5 Gbar. The model is benchmarked against synthetic data from radiation-hydrodynamics simulations, and opens avenues for producing quantitative constraints on physical models relevant to dense astrophysical and laboratory fusion plasmas.
- Open Access
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA.
The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D3He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Open AccessThe next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA.
The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D3He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design of an in-vacuum manipulator for nuclear diagnostics development at the MIT linear electrostatic ion accelerator
An ultrahigh vacuum compatible manipulator known as the Diagnostic Manipulating Element (DiME) has been developed for the MIT Linear Electrostatic Ion Accelerator (LEIA) facility. The system was designed to reduce the resources dedicated toward the calibration process for step-range filters CR-39 based proton spectrometers used in inertial confinement fusion experiments at the Lawrence Livermore National Ignition Facility and the University of Rochester’s OMEGA Laser Facility. To accurately account for variations in nominal filter thicknesses when analyzing experimental data, the spectrometers are calibrated at the MIT LEIA facility prior to use at other facilities. The system supports rapid prototyping and can reduce the time necessary for spectrometer calibration by 50%. The modular design of the DiME is described in this article to facilitate the implementation of similar design methods at other facilities focused on the development of nuclear fusion technologies.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
- Open Access
- 1 February 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (2)
Monte Carlo toolkit for designing and validating step-range-filter spectrometer designs
Here, we present a Monte Carlo toolkit for validating step range filter (SRF) spectrometer designs. Geant4 is used to transport charged particles through the SRF filters to generate synthetic SRF data that include realistic CR-39 effects. Synthetic SRF spectra generated by this method inherently account for instrument response and allow for the quantification of SRF performance before shots. The usefulness of this toolkit is demonstrated through its application to a number of problems. A new broadband SRF for the ∼10 MeV wide 3He3He proton spectrum is validated, and an analysis method for analyzing 3He3He-p SRF data that accounts for instrument response is put forth. In addition, an SRF design for the compact recoil-proton spectrometer (CRS) on the Z-machine is validated. Finally, a new calibration technique for the DD-p SRF is proposed and validated.
- 1 February 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (2)
Open AccessMonte Carlo toolkit for designing and validating step-range-filter spectrometer designs
Here, we present a Monte Carlo toolkit for validating step range filter (SRF) spectrometer designs. Geant4 is used to transport charged particles through the SRF filters to generate synthetic SRF data that include realistic CR-39 effects. Synthetic SRF spectra generated by this method inherently account for instrument response and allow for the quantification of SRF performance before shots. The usefulness of this toolkit is demonstrated through its application to a number of problems. A new broadband SRF for the ∼10 MeV wide 3He3He proton spectrum is validated, and an analysis method for analyzing 3He3He-p SRF data that accounts for instrument response is put forth. In addition, an SRF design for the compact recoil-proton spectrometer (CRS) on the Z-machine is validated. Finally, a new calibration technique for the DD-p SRF is proposed and validated.
- Open Access
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Open AccessUltra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Errors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessErrors in the field reconstruction using CR-39 proton radiographs with high fluence variation
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (≲4 × 104 cm−2) regions and detection efficiency in high-fluence regions (≳7 × 105 cm−2). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in ≳15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 × 103 to 7 × 105 cm−2. Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge–Ampère code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2–7 compared to the reconstructions using only one etch time.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Quantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessQuantifying the effects of neutron fluence on proton signal retention in CR-39
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Image plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessImage plate multi-scan response to fusion protons in the range of 1–14 MeV
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.