Limin Lun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Limin Lun has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Chao Xuan
The Affiliated Hospital of Qingdao University
8 shared publications Qing Wang
Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao 266000, China
7 shared publicationsHui Li
Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao, China
6 shared publicationsGuo-Wei He
Center for Basic Medical Research & Department of Cardiovascular Surgery, TEDA International Cardiovascular Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China
5 shared publicationsQing-Wu Tian
Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao, China
4 shared publicationsWenfei Lu
Department of Laboratory Medicine, The Affiliated Hospital of Qingdao University, Qingdao, China
4 shared publications
Latest Publications
- Open Access
Protocol for a laboratory-developed chromogenic anti-Xa assay for rivaroxaban monitoring
- Top Cited PapersOpen Access
- 12 January 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1745447
In-house chromogenic anti-factor Xa assay: development, validation, and identification of factors predicting APTT discordance
Background: Activated partial thromboplastin time (APTT) is the conventional test for monitoring unfractionated heparin (UFH) therapy, but discordance with anti-factor Xa results frequently occurs in clinical practice, potentially leading to suboptimal anticoagulation management. Objective: This study aimed to develop an in-house anti-factor Xa detection system, establish laboratory-specific APTT therapeutic ranges calibrated against anti-factor Xa levels, and identify predictors of discordance between these two monitoring methods. Methods: We developed and validated a chromogenic anti-factor Xa assay according to CLSI guidelines. From 110 patients receiving UFH, 190 samples were collected. Laboratory-specific APTT ranges were derived using linear regression and ROC analysis against anti-factor Xa target range (0.3–0.7 IU/ml). Random forest and logistic regression models identified predictors of discordance among clinical and laboratory variables. Results: The optimized assay showed excellent analytical performance with strong correlation to the commercial platform (Pearson r = 0.986, R 2 = 0.972). The derived laboratory-specific APTT therapeutic range was 79–127 s. Despite moderate correlation between APTT and anti-factor Xa (Spearman ρ = 0.678, p < 0.001), classification concordance was poor, with 58.2% of specimens showing discordance. Random forest analysis (AUC = 0.79) and logistic regression identified five key predictors: fibrinogen, triglycerides, estimated glomerular filtration rate, C-reactive protein, and antithrombin III. Conclusions: This study developed a validated anti-factor Xa assay and identified substantial classification discordance between APTT and anti-factor Xa monitoring. Five clinical and laboratory factors were associated with monitoring discordance.
- 12 January 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1745447
Top Cited PapersOpen AccessIn-house chromogenic anti-factor Xa assay: development, validation, and identification of factors predicting APTT discordance
Background: Activated partial thromboplastin time (APTT) is the conventional test for monitoring unfractionated heparin (UFH) therapy, but discordance with anti-factor Xa results frequently occurs in clinical practice, potentially leading to suboptimal anticoagulation management. Objective: This study aimed to develop an in-house anti-factor Xa detection system, establish laboratory-specific APTT therapeutic ranges calibrated against anti-factor Xa levels, and identify predictors of discordance between these two monitoring methods. Methods: We developed and validated a chromogenic anti-factor Xa assay according to CLSI guidelines. From 110 patients receiving UFH, 190 samples were collected. Laboratory-specific APTT ranges were derived using linear regression and ROC analysis against anti-factor Xa target range (0.3–0.7 IU/ml). Random forest and logistic regression models identified predictors of discordance among clinical and laboratory variables. Results: The optimized assay showed excellent analytical performance with strong correlation to the commercial platform (Pearson r = 0.986, R 2 = 0.972). The derived laboratory-specific APTT therapeutic range was 79–127 s. Despite moderate correlation between APTT and anti-factor Xa (Spearman ρ = 0.678, p < 0.001), classification concordance was poor, with 58.2% of specimens showing discordance. Random forest analysis (AUC = 0.79) and logistic regression identified five key predictors: fibrinogen, triglycerides, estimated glomerular filtration rate, C-reactive protein, and antithrombin III. Conclusions: This study developed a validated anti-factor Xa assay and identified substantial classification discordance between APTT and anti-factor Xa monitoring. Five clinical and laboratory factors were associated with monitoring discordance.
- Open Access
- 28 November 2025
- Published by Editorial Committee of Japanese Journal of Infectious Diseases, National Institute of Infectious Dis in Japanese Journal of Infectious Diseases
- Vol. 79 (4) , 138-142
Diagnostic value of routine laboratory tests in hemorrhagic fever with renal syndrome in Jiaodong Peninsula, Shandong Province, China
To explore the clinical value of routine laboratory tests in the early diagnosis of hemorrhagic fever with renal syndrome (HFRS), this study retrospectively analyzed the medical records of 146 patients, including 87 HFRS cases and 59 controls. Subsequently, a multivariable logistic regression model was employed to identify clinically relevant indicators for HFRS diagnosis. The sensitivity and specificity of these indicators were further evaluated by using receiver operating characteristic (ROC) curve analysis, both individually and in combination. Results showed that HFRS patients had significantly higher levels of leukocytes, neutrophils, lymphocytes, monocytes, eosinophils, basophils, erythrocytes, urinary proteins, and hemoglobin (all P < 0.05), while platelet counts were lower (P < 0.05). Multivariable logistic regression analysis revealed that monocyte count and hemoglobin were independent predictors of HFRS. The area under the ROC curve (AUC) for the combined use of monocyte count and hemoglobin level in diagnosing HFRS was 0.942, which was significantly higher than the AUC when either was used alone, indicating excellent predictive performance. In conclusion, elevated monocyte count and hemoglobin levels are independent predictors of HFRS. Their combined use enables effective prediction of HFRS and may serve as a key criterion for the early diagnosis of HFRS in primary care settings.
- 28 November 2025
- Published by Editorial Committee of Japanese Journal of Infectious Diseases, National Institute of Infectious Dis in Japanese Journal of Infectious Diseases
- Vol. 79 (4) , 138-142
Open AccessDiagnostic value of routine laboratory tests in hemorrhagic fever with renal syndrome in Jiaodong Peninsula, Shandong Province, China
To explore the clinical value of routine laboratory tests in the early diagnosis of hemorrhagic fever with renal syndrome (HFRS), this study retrospectively analyzed the medical records of 146 patients, including 87 HFRS cases and 59 controls. Subsequently, a multivariable logistic regression model was employed to identify clinically relevant indicators for HFRS diagnosis. The sensitivity and specificity of these indicators were further evaluated by using receiver operating characteristic (ROC) curve analysis, both individually and in combination. Results showed that HFRS patients had significantly higher levels of leukocytes, neutrophils, lymphocytes, monocytes, eosinophils, basophils, erythrocytes, urinary proteins, and hemoglobin (all P < 0.05), while platelet counts were lower (P < 0.05). Multivariable logistic regression analysis revealed that monocyte count and hemoglobin were independent predictors of HFRS. The area under the ROC curve (AUC) for the combined use of monocyte count and hemoglobin level in diagnosing HFRS was 0.942, which was significantly higher than the AUC when either was used alone, indicating excellent predictive performance. In conclusion, elevated monocyte count and hemoglobin levels are independent predictors of HFRS. Their combined use enables effective prediction of HFRS and may serve as a key criterion for the early diagnosis of HFRS in primary care settings.
- Open Access
Magnetic Molecularly Imprinted Polymers for the Rapid and Selective Extraction and Detection of Methotrexatein Serum by HPLC-UV Analysis
In this work, novel selective recognition materials, namely magnetic molecularly imprinted polymers (MMIPs), were prepared. The recognition materials were used as pretreatment materials for magnetic molecularly imprinted solid-phase extraction (MSPE) to achieve the efficient adsorption, selective recognition, and rapid magnetic separation of methotrexate (MTX) in the patients’ plasma. This method was combined with high-performance liquid chromatography–ultraviolet detection (HPLC–UV) to achieve accurate and rapid detection of the plasma MTX concentration, providing a new method for the clinical detection and monitoring of the MTX concentration. The MMIPs for the selective adsorption of MTX were prepared by the sol–gel method. The materials were characterized by transmission electron microscopy, Fourier transform-infrared spectrometry, X-ray diffractometry, and X-ray photoelectron spectrometry. The MTX adsorption properties of the MMIPs were evaluated using static, dynamic, and selective adsorption experiments. On this basis, the extraction conditions were optimized systematically. The adsorption capacity of MMIPs for MTX was 39.56 mgg−1, the imprinting factor was 9.40, and the adsorption equilibrium time was 60 min. The optimal extraction conditions were as follows: the amount of MMIP was 100 mg, the loading time was 120 min, the leachate was 8:2 (v/v) water–methanol, the eluent was 4:1 (v/v) methanol–acetic acid, and the elution time was 60 min. MTX was linear in the range of 0.00005–0.25 mg mL−1, and the detection limit was 12.51 ng mL−1. The accuracy of the MSPE–HPLC–UV method for MTX detection was excellent, and the result was consistent with that of a drug concentration analyzer.
Open AccessMagnetic Molecularly Imprinted Polymers for the Rapid and Selective Extraction and Detection of Methotrexatein Serum by HPLC-UV Analysis
In this work, novel selective recognition materials, namely magnetic molecularly imprinted polymers (MMIPs), were prepared. The recognition materials were used as pretreatment materials for magnetic molecularly imprinted solid-phase extraction (MSPE) to achieve the efficient adsorption, selective recognition, and rapid magnetic separation of methotrexate (MTX) in the patients’ plasma. This method was combined with high-performance liquid chromatography–ultraviolet detection (HPLC–UV) to achieve accurate and rapid detection of the plasma MTX concentration, providing a new method for the clinical detection and monitoring of the MTX concentration. The MMIPs for the selective adsorption of MTX were prepared by the sol–gel method. The materials were characterized by transmission electron microscopy, Fourier transform-infrared spectrometry, X-ray diffractometry, and X-ray photoelectron spectrometry. The MTX adsorption properties of the MMIPs were evaluated using static, dynamic, and selective adsorption experiments. On this basis, the extraction conditions were optimized systematically. The adsorption capacity of MMIPs for MTX was 39.56 mgg−1, the imprinting factor was 9.40, and the adsorption equilibrium time was 60 min. The optimal extraction conditions were as follows: the amount of MMIP was 100 mg, the loading time was 120 min, the leachate was 8:2 (v/v) water–methanol, the eluent was 4:1 (v/v) methanol–acetic acid, and the elution time was 60 min. MTX was linear in the range of 0.00005–0.25 mg mL−1, and the detection limit was 12.51 ng mL−1. The accuracy of the MSPE–HPLC–UV method for MTX detection was excellent, and the result was consistent with that of a drug concentration analyzer.
- Open Access
- 13 November 2021
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (12) , e24109
Establishment of a new protein C detection system based on chromogenic substrate assay and its clinical diagnostic value for deep vein thrombosis
Background: Deficiency of protein C (PC) affects the balance between blood coagulation and fibrinolysis in the human body. Chromogenic‐based assay is recommended as the preferred screening method for detecting PC deficiency. We established a PC detection system based on the chromogenic substrate assay.Methods: First, a kit for the determination of PC activity in plasma was elaborately developed and its reaction parameters on XL‐3200c were explored. Then, we evaluated its performance and collected specimens to compare the test results obtained with those of the Siemens detection system. Finally, the clinical diagnostic efficacy of this detection system for deep vein thrombosis (DVT) was assessed.Results: Optimum conditions for PC detection were 0.25–0.1 U/ml protein C activator Protac® and 2.5–1 mM Pefachrome®PCa5297. The composition and concentration ranges of buffer substances and stabilizers in the kit were also explored. Satisfactory results were observed in performance evaluation. The test results of the newly built detection system were highly correlated with those of the Siemens detection system (R2 = 0.9771 in the control group and R2 = 0.9776 in the DVT group), and Bland‐Altman plots also showed high consistency between the two detection systems. In addition, the area under the curve (AUC) of the newly built PC detection system for DVT was 0.888, indicating this system could effectively improve the diagnostic sensitivity and specificity for DVT.Conclusion: In this study, a sensitive, wide linear range and reliable PC activity detection system were established.
- 13 November 2021
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (12) , e24109
Open AccessEstablishment of a new protein C detection system based on chromogenic substrate assay and its clinical diagnostic value for deep vein thrombosis
Background: Deficiency of protein C (PC) affects the balance between blood coagulation and fibrinolysis in the human body. Chromogenic‐based assay is recommended as the preferred screening method for detecting PC deficiency. We established a PC detection system based on the chromogenic substrate assay.Methods: First, a kit for the determination of PC activity in plasma was elaborately developed and its reaction parameters on XL‐3200c were explored. Then, we evaluated its performance and collected specimens to compare the test results obtained with those of the Siemens detection system. Finally, the clinical diagnostic efficacy of this detection system for deep vein thrombosis (DVT) was assessed.Results: Optimum conditions for PC detection were 0.25–0.1 U/ml protein C activator Protac® and 2.5–1 mM Pefachrome®PCa5297. The composition and concentration ranges of buffer substances and stabilizers in the kit were also explored. Satisfactory results were observed in performance evaluation. The test results of the newly built detection system were highly correlated with those of the Siemens detection system (R2 = 0.9771 in the control group and R2 = 0.9776 in the DVT group), and Bland‐Altman plots also showed high consistency between the two detection systems. In addition, the area under the curve (AUC) of the newly built PC detection system for DVT was 0.888, indicating this system could effectively improve the diagnostic sensitivity and specificity for DVT.Conclusion: In this study, a sensitive, wide linear range and reliable PC activity detection system were established.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Therapeutic Advances in Chronic Disease
- Vol. 12
Serum fatty acids profile and association with early-onset coronary artery disease
Background: Fatty acids (FAs) play crucial roles in modulating and preventing diseases in humans, including early-onset coronary artery disease (EOCAD). In this study, we aimed to provide a profile of FAs in the serum of EOCAD patients and identify potential EOCAD-associated FAs. Methods: In the first stage, we analyzed the FAs profiles in pooled samples of patients with EOCAD using gas chromatography-mass spectrometry. In the second stage, the serum levels of the candidate FAs were validated in EOCAD patients. Results: A total of 128 EOCAD patients and 64 controls were included in the study. Forty-nine serum FAs were quantified in pooled samples; three ω-3 FAs were identified to be associated with EOCAD. Moreover, results from the validation stage indicated that serum levels of docosahexaenoic acid (DHA) were significantly lower in EOCAD patients (55.43 ± 33.86 µg/ml) and myocardial infarction (MI) patients (47.49 ± 28.44 μg/ml) than those in the controls (70.65 ± 43.56 µg/ml). Multivariate regression analysis revealed that elevated serum DHA level was an independent protective factor for EOCAD [odds ratio (OR) = 0.8917, 95% confidence interval (CI): 0.879–0.957] and MI (OR = 0.835, 95% CI: 0.799–0.862). Decreased serum levels of docosapentaenoic acid (DPA) and eicosapentaenoic acid (EPA) were observed in the early-onset MI group. Conclusion: The study provided the serum FAs profile of EOCAD and confirmed that the decrease in serum levels of DHA, DPA, and EPA was associated with EOCAD. These findings might contribute to understanding the cardiovascular effects of FAs, particularly the protective effects of ω-3 polyunsaturated FAs.
- 1 January 2021
- Published by SAGE Publications in Therapeutic Advances in Chronic Disease
- Vol. 12
Open AccessSerum fatty acids profile and association with early-onset coronary artery disease
Background: Fatty acids (FAs) play crucial roles in modulating and preventing diseases in humans, including early-onset coronary artery disease (EOCAD). In this study, we aimed to provide a profile of FAs in the serum of EOCAD patients and identify potential EOCAD-associated FAs. Methods: In the first stage, we analyzed the FAs profiles in pooled samples of patients with EOCAD using gas chromatography-mass spectrometry. In the second stage, the serum levels of the candidate FAs were validated in EOCAD patients. Results: A total of 128 EOCAD patients and 64 controls were included in the study. Forty-nine serum FAs were quantified in pooled samples; three ω-3 FAs were identified to be associated with EOCAD. Moreover, results from the validation stage indicated that serum levels of docosahexaenoic acid (DHA) were significantly lower in EOCAD patients (55.43 ± 33.86 µg/ml) and myocardial infarction (MI) patients (47.49 ± 28.44 μg/ml) than those in the controls (70.65 ± 43.56 µg/ml). Multivariate regression analysis revealed that elevated serum DHA level was an independent protective factor for EOCAD [odds ratio (OR) = 0.8917, 95% confidence interval (CI): 0.879–0.957] and MI (OR = 0.835, 95% CI: 0.799–0.862). Decreased serum levels of docosapentaenoic acid (DPA) and eicosapentaenoic acid (EPA) were observed in the early-onset MI group. Conclusion: The study provided the serum FAs profile of EOCAD and confirmed that the decrease in serum levels of DHA, DPA, and EPA was associated with EOCAD. These findings might contribute to understanding the cardiovascular effects of FAs, particularly the protective effects of ω-3 polyunsaturated FAs.
- Open Access
- 26 November 2020
- Published by Wiley in Disease Markers
- Vol. 2020, 1-9
Interleukin-18 Is a Prognostic Marker and Plays a Tumor Suppressive Role in Colon Cancer
Interleukin-18 (IL-18) belongs to the IL-1 family and is an essential proinflammatory and immune regulatory cytokine. The present study was designed to investigate the expression and function of IL-18 in colon cancer. In clinical analyses, mRNA and protein expressions of IL-18 were decreased in tissues of colon cancer patients. This decreased expression of IL-18 was significantly correlated with the tumor size ( ) and American Joint Committee on Cancer (AJCC) stage ( ). Patients with IL-18-positive tumors had a better survival rate than patients with IL-18-negative tumors. Moreover, upregulation of IL-18 inhibited colon cancer cell proliferation. Our data suggest that the decreased expression of IL-18 in colon cancer was associated with prognosis and tumor proliferation. IL-18 may be considered a novel tumor suppressor and a potential therapeutic target for colon cancer patients.
- 26 November 2020
- Published by Wiley in Disease Markers
- Vol. 2020, 1-9
Open AccessInterleukin-18 Is a Prognostic Marker and Plays a Tumor Suppressive Role in Colon Cancer
Interleukin-18 (IL-18) belongs to the IL-1 family and is an essential proinflammatory and immune regulatory cytokine. The present study was designed to investigate the expression and function of IL-18 in colon cancer. In clinical analyses, mRNA and protein expressions of IL-18 were decreased in tissues of colon cancer patients. This decreased expression of IL-18 was significantly correlated with the tumor size ( ) and American Joint Committee on Cancer (AJCC) stage ( ). Patients with IL-18-positive tumors had a better survival rate than patients with IL-18-negative tumors. Moreover, upregulation of IL-18 inhibited colon cancer cell proliferation. Our data suggest that the decreased expression of IL-18 in colon cancer was associated with prognosis and tumor proliferation. IL-18 may be considered a novel tumor suppressor and a potential therapeutic target for colon cancer patients.
- 26 November 2020
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (5) , 538-546
Elevated RUNX1 is a prognostic biomarker for human head and neck squamous cell carcinoma
Runt-related transcription factors regulate many developmental processes such as proliferation and differentiation. In this study, the function of the runt-related transcription factor 1 (RUNX1) was investigated in head and neck squamous cell carcinoma (HNSCC). Our results show that RUNX1 expression was elevated in HNSCC patients, which was greatly correlated with the N stage, tumor size, and American Joint Committee on Cancer stage. Cox proportional hazard models showed that RUNX1 could be used as a prognostic indicator for the overall survival of HNSCC patients (hazard ratio, 5.572; 95% confidence interval, 1.860–9.963; P < 0.001). Moreover, suppression of RUNX1 inhibited HNSCC cell proliferation, migration, and invasion. Using the HNSCC xenograft nude mouse model, we found that the shRUNX1-transfected tumor (sh-RUNX1) was significantly smaller both in size and weight than the control vector-transfected tumor (sh-Control). In conclusion, our results show that the elevated RUNX1 expression was correlated with tumor growth and metastasis in HNSCC, indicating that RUNX1 could be used as a biomarker for tumor recurrence and prognosis.
- 26 November 2020
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (5) , 538-546
Elevated RUNX1 is a prognostic biomarker for human head and neck squamous cell carcinoma
Runt-related transcription factors regulate many developmental processes such as proliferation and differentiation. In this study, the function of the runt-related transcription factor 1 (RUNX1) was investigated in head and neck squamous cell carcinoma (HNSCC). Our results show that RUNX1 expression was elevated in HNSCC patients, which was greatly correlated with the N stage, tumor size, and American Joint Committee on Cancer stage. Cox proportional hazard models showed that RUNX1 could be used as a prognostic indicator for the overall survival of HNSCC patients (hazard ratio, 5.572; 95% confidence interval, 1.860–9.963; P < 0.001). Moreover, suppression of RUNX1 inhibited HNSCC cell proliferation, migration, and invasion. Using the HNSCC xenograft nude mouse model, we found that the shRUNX1-transfected tumor (sh-RUNX1) was significantly smaller both in size and weight than the control vector-transfected tumor (sh-Control). In conclusion, our results show that the elevated RUNX1 expression was correlated with tumor growth and metastasis in HNSCC, indicating that RUNX1 could be used as a biomarker for tumor recurrence and prognosis.