Magdalena Medrzycki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Magdalena Medrzycki has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Amanda K. Lyons
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
3 shared publications - Angela Coulliette-Salmond
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
3 shared publications - Christine Ganim
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
3 shared publications - Mariya Campbell
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
3 shared publications - Maroya Spalding Walters
Division of Healthcare Quality Promotion, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
3 shared publications - Adam C. Retchless
Coronavirus and Other Respiratory Viruses Division, National Center for Immunization and Respiratory Diseases, Centers for Disease Control and Prevention, 1600 Clifton Rd., Atlanta, GA 30329, USA
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IWA Publishing in Journal of Water and Health
- Vol. 24 (10) , 1472-1486
Insights from wastewater surveillance of SARS-CoV-2 in skilled nursing facilities: comparing virus concentration methods for wastewater and correlating wastewater virus concentrations with clinical infections, Georgia, USA, 2022
A pictographic representation of the text abstract showing wastewater and epidemiologic data flow and data integration. To understand the utility of healthcare facility-level wastewater surveillance (WWS) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), it is important to correlate wastewater SARS-CoV-2 RNA detection with the number of clinical infections. WWS for SARS-CoV-2 was performed at three skilled nursing facilities (SNFs) over 25 weeks. Electronegative membrane filtration (enMF) and Nanotrap® Magnetic Virus Particles (NP) virus concentration methods were compared. Extracts were tested by droplet digital polymerase chain reaction. Spearman's correlations (ρ) between wastewater virus RNA concentrations and infection counts were calculated. From split wastewater samples, enMF recovered higher SARS-CoV-2 RNA concentrations than NP. Combining data from all facilities, the median concentrations were 53.0 versus 38.6 gc/100 mL for enMF and NP, respectively (p = 0.001). Using enMF, correlations were moderate to strong at SNF A (ρ ranged 0.67–0.86, all p-values <0.001). Weak to moderate correlations may reflect the sampled manhole not representing the entire facility (SNF B, ρ ranged 0.47–0.72, p-values ranged <0.001–0.12) and longitudinal data gaps from summer heat and equipment maintenance (SNF C, ρ ranged 0.14–0.59, p-values ranged<0.01 to 0.52). WWS can be a valuable tool for tracking dynamics of SARS-CoV-2 infections in healthcare facilities.
- 1 October 2026
- Published by IWA Publishing in Journal of Water and Health
- Vol. 24 (10) , 1472-1486
Open AccessInsights from wastewater surveillance of SARS-CoV-2 in skilled nursing facilities: comparing virus concentration methods for wastewater and correlating wastewater virus concentrations with clinical infections, Georgia, USA, 2022
A pictographic representation of the text abstract showing wastewater and epidemiologic data flow and data integration. To understand the utility of healthcare facility-level wastewater surveillance (WWS) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), it is important to correlate wastewater SARS-CoV-2 RNA detection with the number of clinical infections. WWS for SARS-CoV-2 was performed at three skilled nursing facilities (SNFs) over 25 weeks. Electronegative membrane filtration (enMF) and Nanotrap® Magnetic Virus Particles (NP) virus concentration methods were compared. Extracts were tested by droplet digital polymerase chain reaction. Spearman's correlations (ρ) between wastewater virus RNA concentrations and infection counts were calculated. From split wastewater samples, enMF recovered higher SARS-CoV-2 RNA concentrations than NP. Combining data from all facilities, the median concentrations were 53.0 versus 38.6 gc/100 mL for enMF and NP, respectively (p = 0.001). Using enMF, correlations were moderate to strong at SNF A (ρ ranged 0.67–0.86, all p-values <0.001). Weak to moderate correlations may reflect the sampled manhole not representing the entire facility (SNF B, ρ ranged 0.47–0.72, p-values ranged <0.001–0.12) and longitudinal data gaps from summer heat and equipment maintenance (SNF C, ρ ranged 0.14–0.59, p-values ranged<0.01 to 0.52). WWS can be a valuable tool for tracking dynamics of SARS-CoV-2 infections in healthcare facilities.
- Open Access
- 22 December 2025
- Published by IWA Publishing in Journal of Water and Health
- Vol. 24 (1) , 50-64
Healthcare wastewater surveillance: methodological considerations for sampling, feasibility, and implementation
Wastewater surveillance (WWS) at healthcare facilities is a nascent field with knowledge gaps in the feasibility of conducting such surveillance at this specialized facility type, and for how to best implement and interpret wastewater (WW) data. WWS was piloted at skilled nursing facilities, including conducting tracer studies, optimization of a low-flow strainer for autosampler WW collection, and preliminary testing of a WW access survey. An expanded WW access survey with collaboration from additional partners was distributed to 16 post-acute/long-term care facilities. The lessons learned obtained through the pilot ‘use cases’ demonstrated minimal clogging and consistent collection of WW using a low-flow strainer (±0.36 L) and tracer studies highlighted the importance to confirm facility effluent source with an average visual dye detection between 1.5 and 2.5 min from the toilet flush. The expanded WW access survey assessed the feasibility of WWS regarding physical onsite manhole access, safety aspects, effluent flow, and other factors, where 75% (12 of 16) of surveyed facilities demonstrated feasibility. Healthcare facility-level WWS includes specialized methodological approaches prior to implementation to achieve the intended public health impact. These considerations support the continued overall goal of detecting emerging biological public health threats at healthcare facilities using WWS.
- 22 December 2025
- Published by IWA Publishing in Journal of Water and Health
- Vol. 24 (1) , 50-64
Open AccessHealthcare wastewater surveillance: methodological considerations for sampling, feasibility, and implementation
Wastewater surveillance (WWS) at healthcare facilities is a nascent field with knowledge gaps in the feasibility of conducting such surveillance at this specialized facility type, and for how to best implement and interpret wastewater (WW) data. WWS was piloted at skilled nursing facilities, including conducting tracer studies, optimization of a low-flow strainer for autosampler WW collection, and preliminary testing of a WW access survey. An expanded WW access survey with collaboration from additional partners was distributed to 16 post-acute/long-term care facilities. The lessons learned obtained through the pilot ‘use cases’ demonstrated minimal clogging and consistent collection of WW using a low-flow strainer (±0.36 L) and tracer studies highlighted the importance to confirm facility effluent source with an average visual dye detection between 1.5 and 2.5 min from the toilet flush. The expanded WW access survey assessed the feasibility of WWS regarding physical onsite manhole access, safety aspects, effluent flow, and other factors, where 75% (12 of 16) of surveyed facilities demonstrated feasibility. Healthcare facility-level WWS includes specialized methodological approaches prior to implementation to achieve the intended public health impact. These considerations support the continued overall goal of detecting emerging biological public health threats at healthcare facilities using WWS.
- Open Access
- 25 October 2025
- Published by Elsevier in The Lancet Microbe
- Vol. 6 (12) , 101201
New Delhi metallo-β-lactamase-producing Acinetobacter baumannii in the USA from October, 2013, to March, 2022: a retrospective molecular epidemiological analysis
- 25 October 2025
- Published by Elsevier in The Lancet Microbe
- Vol. 6 (12) , 101201
Open AccessNew Delhi metallo-β-lactamase-producing Acinetobacter baumannii in the USA from October, 2013, to March, 2022: a retrospective molecular epidemiological analysis
- Open Access
- 9 May 2025
- Published by IWA Publishing in Journal of Water and Health
- Vol. 23 (6) , 727-742
Skilled nursing facility wastewater surveillance: a SARS-CoV-2 and antimicrobial resistance detection pilot study
The purpose of this study was to determine the feasibility of facility-level wastewater surveillance in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in skilled nursing facility (SNF) wastewater using three concentration methods, as well as a proof-of-concept for antimicrobial resistance (AR) genes/organisms detection. Wastewater effluent samples were collected from an SNF over an 8-week period. Wastewater was concentrated using electronegative membrane filtration (enMF), polyethylene glycol precipitation, and Nanotrap® magnetic virus particles (NP). Quantification of the genome copy concentration from SARS-CoV-2 and bovine respiratory syncytial virus (BRSV), a SARS-CoV-2 surrogate spiked into all samples, was performed with droplet digital polymerase chain reaction (ddPCR). Wastewater sample aliquots were also enriched in microbiological culture media and screened for organisms with AR phenotypes on selective and differential agars. Multiplex real-time PCR was used to detect a broad array of carbapenem resistance genes. SARS-CoV-2 was detected and quantified from a single enMF-concentrated wastewater sample. The highest concentration of BRSV came from enMF-concentrated samples. Klebsiella, Enterobacter, Citrobacter, and Escherichia coli exhibiting AR phenotypes were successfully detected using culture-dependent approaches. Culture-independent, multiplex PCR indicated that blaKPC was the main carbapenemase gene detected in wastewater samples. Facility-level wastewater surveillance could be a useful strategy for SNFs.
- 9 May 2025
- Published by IWA Publishing in Journal of Water and Health
- Vol. 23 (6) , 727-742
Open AccessSkilled nursing facility wastewater surveillance: a SARS-CoV-2 and antimicrobial resistance detection pilot study
The purpose of this study was to determine the feasibility of facility-level wastewater surveillance in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in skilled nursing facility (SNF) wastewater using three concentration methods, as well as a proof-of-concept for antimicrobial resistance (AR) genes/organisms detection. Wastewater effluent samples were collected from an SNF over an 8-week period. Wastewater was concentrated using electronegative membrane filtration (enMF), polyethylene glycol precipitation, and Nanotrap® magnetic virus particles (NP). Quantification of the genome copy concentration from SARS-CoV-2 and bovine respiratory syncytial virus (BRSV), a SARS-CoV-2 surrogate spiked into all samples, was performed with droplet digital polymerase chain reaction (ddPCR). Wastewater sample aliquots were also enriched in microbiological culture media and screened for organisms with AR phenotypes on selective and differential agars. Multiplex real-time PCR was used to detect a broad array of carbapenem resistance genes. SARS-CoV-2 was detected and quantified from a single enMF-concentrated wastewater sample. The highest concentration of BRSV came from enMF-concentrated samples. Klebsiella, Enterobacter, Citrobacter, and Escherichia coli exhibiting AR phenotypes were successfully detected using culture-dependent approaches. Culture-independent, multiplex PCR indicated that blaKPC was the main carbapenemase gene detected in wastewater samples. Facility-level wastewater surveillance could be a useful strategy for SNFs.
- Open Access
- 1 July 2021
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 174 (7) , 945-951
Performance Evaluation of Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak
It has been hoped that rapid SARS-CoV-2 antigen testing could reduce the tragic toll of COVID-19 in nursing homes. The performance of the BinaxNOW antigen test in a nursing home during an ongoing S... Visual Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak. It has been hoped that rapid SARS-CoV-2 antigen testing could reduce the tragic toll of COVID-19 in nursing h... Background: To address high COVID-19 burden in U.S. nursing homes, rapid SARS-CoV-2 antigen tests have been widely distributed in those facilities. However, performance data are lacking, especially...
- 1 July 2021
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 174 (7) , 945-951
Open AccessPerformance Evaluation of Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak
It has been hoped that rapid SARS-CoV-2 antigen testing could reduce the tragic toll of COVID-19 in nursing homes. The performance of the BinaxNOW antigen test in a nursing home during an ongoing S... Visual Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak. It has been hoped that rapid SARS-CoV-2 antigen testing could reduce the tragic toll of COVID-19 in nursing h... Background: To address high COVID-19 burden in U.S. nursing homes, rapid SARS-CoV-2 antigen tests have been widely distributed in those facilities. However, performance data are lacking, especially...
- 18 August 2020
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 27 (12) , 1484-1494
Hepatitis A virus survival on drug paraphernalia
The ongoing hepatitis A outbreaks in multiple states in the United States have concerned public health authorities since March 2017. The outbreaks have spread throughout 30 states and include primarily persons who use drugs, including persons who inject drugs (PWID) and persons experiencing homelessness. Contaminated drug injection paraphernalia and sharing of these items could potentially aid in transmission of hepatitis A virus (HAV) among these populations. We examined HAV survival on drug paraphernalia frequently shared among PWIDs. The effect of low pH on HAV survival using citric acid, which is frequently used by PWIDs during dose preparation, was investigated. We compared the plaque assay results with those concurrently obtained by qRT‐PCR to establish whether HAV RNA levels could be used as surrogates for plaque assay results. HAV suspended in minimal essential media at room temperature infected FRhK4 cells for more than 17 weeks. HAV remained viable in syringes/needles for up to 10 weeks depending on the gauge of the needles and the syringe dead volumes, and on cookers, tourniquets and cotton balls/filter surfaces for up to 4 weeks. HAV retained its infectivity for more than 10 weeks at pH as low as 2. In conclusion, our findings show that HAV survives and remains infective in or on injection drug use equipment for 1 to 10 weeks depending on the type of paraphernalia examined and environmental conditions. These findings suggest that contaminated drug paraphernalia can potentially facilitate the transmission of HAV within populations who share these items.
- 18 August 2020
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 27 (12) , 1484-1494
Hepatitis A virus survival on drug paraphernalia
The ongoing hepatitis A outbreaks in multiple states in the United States have concerned public health authorities since March 2017. The outbreaks have spread throughout 30 states and include primarily persons who use drugs, including persons who inject drugs (PWID) and persons experiencing homelessness. Contaminated drug injection paraphernalia and sharing of these items could potentially aid in transmission of hepatitis A virus (HAV) among these populations. We examined HAV survival on drug paraphernalia frequently shared among PWIDs. The effect of low pH on HAV survival using citric acid, which is frequently used by PWIDs during dose preparation, was investigated. We compared the plaque assay results with those concurrently obtained by qRT‐PCR to establish whether HAV RNA levels could be used as surrogates for plaque assay results. HAV suspended in minimal essential media at room temperature infected FRhK4 cells for more than 17 weeks. HAV remained viable in syringes/needles for up to 10 weeks depending on the gauge of the needles and the syringe dead volumes, and on cookers, tourniquets and cotton balls/filter surfaces for up to 4 weeks. HAV retained its infectivity for more than 10 weeks at pH as low as 2. In conclusion, our findings show that HAV survives and remains infective in or on injection drug use equipment for 1 to 10 weeks depending on the type of paraphernalia examined and environmental conditions. These findings suggest that contaminated drug paraphernalia can potentially facilitate the transmission of HAV within populations who share these items.
- Open Access
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 358-358:15
Automated quality control for a molecular surveillance system
Molecular surveillance and outbreak investigation are important for elimination of hepatitis C virus (HCV) infection in the United States. A web-based system, Global Hepatitis Outbreak and Surveillance Technology (GHOST), has been developed using Illumina MiSeq-based amplicon sequence data derived from the HCV E1/E2-junction genomic region to enable public health institutions to conduct cost-effective and accurate molecular surveillance, outbreak detection and strain characterization. However, as there are many factors that could impact input data quality to which the GHOST system is not completely immune, accuracy of epidemiological inferences generated by GHOST may be affected. Here, we analyze the data submitted to the GHOST system during its pilot phase to assess the nature of the data and to identify common quality concerns that can be detected and corrected automatically. The GHOST quality control filters were individually examined, and quality failure rates were measured for all samples, including negative controls. New filters were developed and introduced to detect primer dimers, loss of specimen-specific product, or short products. The genotyping tool was adjusted to improve the accuracy of subtype calls. The identification of “chordless” cycles in a transmission network from data generated with known laboratory-based quality concerns allowed for further improvement of transmission detection by GHOST in surveillance settings. Parameters derived to detect actionable common quality control anomalies were incorporated into the automatic quality control module that rejects data depending on the magnitude of a quality problem, and warns and guides users in performing correctional actions. The guiding responses generated by the system are tailored to the GHOST laboratory protocol. Several new quality control problems were identified in MiSeq data submitted to GHOST and used to improve protection of the system from erroneous data and users from erroneous inferences. The GHOST system was upgraded to include identification of causes of erroneous data and recommendation of corrective actions to laboratory users.
- 22 October 2018
- Published by Springer Nature in BMC Bioinformatics
- Vol. 19 (S11) , 358-358:15
Open AccessAutomated quality control for a molecular surveillance system
Molecular surveillance and outbreak investigation are important for elimination of hepatitis C virus (HCV) infection in the United States. A web-based system, Global Hepatitis Outbreak and Surveillance Technology (GHOST), has been developed using Illumina MiSeq-based amplicon sequence data derived from the HCV E1/E2-junction genomic region to enable public health institutions to conduct cost-effective and accurate molecular surveillance, outbreak detection and strain characterization. However, as there are many factors that could impact input data quality to which the GHOST system is not completely immune, accuracy of epidemiological inferences generated by GHOST may be affected. Here, we analyze the data submitted to the GHOST system during its pilot phase to assess the nature of the data and to identify common quality concerns that can be detected and corrected automatically. The GHOST quality control filters were individually examined, and quality failure rates were measured for all samples, including negative controls. New filters were developed and introduced to detect primer dimers, loss of specimen-specific product, or short products. The genotyping tool was adjusted to improve the accuracy of subtype calls. The identification of “chordless” cycles in a transmission network from data generated with known laboratory-based quality concerns allowed for further improvement of transmission detection by GHOST in surveillance settings. Parameters derived to detect actionable common quality control anomalies were incorporated into the automatic quality control module that rejects data depending on the magnitude of a quality problem, and warns and guides users in performing correctional actions. The guiding responses generated by the system are tailored to the GHOST laboratory protocol. Several new quality control problems were identified in MiSeq data submitted to GHOST and used to improve protection of the system from erroneous data and users from erroneous inferences. The GHOST system was upgraded to include identification of causes of erroneous data and recommendation of corrective actions to laboratory users.
- Open Access
- 6 December 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (S10) , 916
GHOST: global hepatitis outbreak and surveillance technology
Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics expertise. Improvement in molecular detection capacity will contribute to increasing the rate of transmission detection, thus providing opportunity for rapid, accurate and effective response to outbreaks of hepatitis C. Although GHOST was originally developed for hepatitis C surveillance, its modular structure is readily applicable to other infectious diseases. Worldwide availability of GHOST for the detection of HCV transmissions will foster deeper involvement of public health researchers and practitioners in hepatitis C outbreak investigation.
- 6 December 2017
- Published by Springer Nature in BMC Genomics
- Vol. 18 (S10) , 916
Open AccessGHOST: global hepatitis outbreak and surveillance technology
Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics expertise. Improvement in molecular detection capacity will contribute to increasing the rate of transmission detection, thus providing opportunity for rapid, accurate and effective response to outbreaks of hepatitis C. Although GHOST was originally developed for hepatitis C surveillance, its modular structure is readily applicable to other infectious diseases. Worldwide availability of GHOST for the detection of HCV transmissions will foster deeper involvement of public health researchers and practitioners in hepatitis C outbreak investigation.