Gil-Joong Yoon
Research Subjects
Gil-Joong Yoon has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Dong Hui Lim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
3 shared publicationsJaeryung Kim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
3 shared publicationsSung-Ho Choi
BALGEUN-EYE21 Operation Center, Gwangju, Republic of Korea
3 shared publications- Tae-Young Chung
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
3 shared publications Chan Min Yang
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
1 shared publicationSumi Kim
Department of Dentistry, Hallym University Gangnam Sacred Heart Hospital, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 29 December 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-2
Correction to: Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK
An amendment to this paper has been published and can be accessed via the original article.
- 29 December 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-2
Open AccessCorrection to: Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK
An amendment to this paper has been published and can be accessed via the original article.
- Open Access
- 14 May 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-9
Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK
Background: To compare the outcomes of myopia and myopic astigmatism corrected with topography-modified refraction laser in situ keratomileusis (TMR-LASIK), wavefront-optimized (WFO) LASIK, and topography-guided (TG) LASIK with a correction target based on the manifest refraction (manifest TG-LASIK). Methods: This observational, retrospective cohort study included patients who underwent LASIK using the WaveLight® EX500 excimer laser to correct myopia and myopic astigmatism between August 2016 and July 2017. Patients who underwent TMR-LASIK (85 patients), WFO-LASIK (70 patients), or manifest TG-LASIK (40 patients) were enrolled, and only one eye from each patient was analyzed. All participants underwent measurement of the uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), manifest refraction, vector analysis of astigmatic change, corneal topography, and corneal wavefront analysis at baseline and at every posttreatment visit. Results: Three months postoperatively, a UDVA of 0.0 logMAR or better and manifest refraction spherical equivalent (MRSE) within ±0.5 diopters (D) did not differ across the TMR-, WFO-, and manifest TG-LASIK groups. However, the residual cylinder in the TMR group was significantly larger than that in the WFO and manifest TG groups. The magnitude of error in the TMR group measured using astigmatism vector analysis was significantly higher than that in the WFO and manifest TG groups. Conclusions: Although these three LASIK platforms achieved the predicted surgical outcomes, TMR-LASIK overcorrected astigmatism and showed a higher residual postoperative astigmatism compared with WFO- and manifest TG-LASIK.
- 14 May 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-9
Open AccessComparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK
Background: To compare the outcomes of myopia and myopic astigmatism corrected with topography-modified refraction laser in situ keratomileusis (TMR-LASIK), wavefront-optimized (WFO) LASIK, and topography-guided (TG) LASIK with a correction target based on the manifest refraction (manifest TG-LASIK). Methods: This observational, retrospective cohort study included patients who underwent LASIK using the WaveLight® EX500 excimer laser to correct myopia and myopic astigmatism between August 2016 and July 2017. Patients who underwent TMR-LASIK (85 patients), WFO-LASIK (70 patients), or manifest TG-LASIK (40 patients) were enrolled, and only one eye from each patient was analyzed. All participants underwent measurement of the uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), manifest refraction, vector analysis of astigmatic change, corneal topography, and corneal wavefront analysis at baseline and at every posttreatment visit. Results: Three months postoperatively, a UDVA of 0.0 logMAR or better and manifest refraction spherical equivalent (MRSE) within ±0.5 diopters (D) did not differ across the TMR-, WFO-, and manifest TG-LASIK groups. However, the residual cylinder in the TMR group was significantly larger than that in the WFO and manifest TG groups. The magnitude of error in the TMR group measured using astigmatism vector analysis was significantly higher than that in the WFO and manifest TG groups. Conclusions: Although these three LASIK platforms achieved the predicted surgical outcomes, TMR-LASIK overcorrected astigmatism and showed a higher residual postoperative astigmatism compared with WFO- and manifest TG-LASIK.
- 1 July 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (7) , 959-965
Topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia: Surgical outcomes
To compare the outcomes of topography-guided and wavefront-optimized surgery in patients having laser in situ keratomileusis (LASIK) for myopia. Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, and BALGEUN-EYE21 Operation Center, Gwangju, South Korea. Prospective case study. Patients had topography-guided LASIK in 1 eye and wavefront-optimized LASIK in the contralateral eye using Contoura Vision software and the WaveLight EX500 excimer laser. Refractive and visual outcomes were analyzed 3 months postoperatively. The study comprised 43 patients. In both groups, the postoperative uncorrected distance visual acuity (UDVA) was 0.0 logarithm of the minimum angle of resolution or better in 90.7% of eyes and the residual spherical equivalent (SE) refractive error was ±0.75 diopter (D) in 81.4% of eyes. The UDVA, residual SE refractive error, and astigmatism did not differ significantly between the 2 groups. There was significant induction of higher-order aberrations (HOAs) in both groups, although corneal coma and trefoil did not increase and ocular trefoil decreased significantly in the topography-guided group (P = .038). However, in the wavefront-optimized group, corneal coma and trefoil increased significantly (P < .001 and P = .046, respectively) and ocular trefoil did not change significantly. In addition, topography-guided LASIK induced significantly fewer corneal total HOAs (P < .001), coma (P < .001), and trefoil (P = .020) than wavefront-optimized LASIK. Although both topography-guided LASIK and wavefront-optimized LASIK safely and effectively achieved the predicted refractive and visual outcomes, topography-guided LASIK induced fewer HOAs and significantly decreased ocular trefoil, corneal total HOAs, and coma.
- 1 July 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (7) , 959-965
Topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia: Surgical outcomes
To compare the outcomes of topography-guided and wavefront-optimized surgery in patients having laser in situ keratomileusis (LASIK) for myopia. Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, and BALGEUN-EYE21 Operation Center, Gwangju, South Korea. Prospective case study. Patients had topography-guided LASIK in 1 eye and wavefront-optimized LASIK in the contralateral eye using Contoura Vision software and the WaveLight EX500 excimer laser. Refractive and visual outcomes were analyzed 3 months postoperatively. The study comprised 43 patients. In both groups, the postoperative uncorrected distance visual acuity (UDVA) was 0.0 logarithm of the minimum angle of resolution or better in 90.7% of eyes and the residual spherical equivalent (SE) refractive error was ±0.75 diopter (D) in 81.4% of eyes. The UDVA, residual SE refractive error, and astigmatism did not differ significantly between the 2 groups. There was significant induction of higher-order aberrations (HOAs) in both groups, although corneal coma and trefoil did not increase and ocular trefoil decreased significantly in the topography-guided group (P = .038). However, in the wavefront-optimized group, corneal coma and trefoil increased significantly (P < .001 and P = .046, respectively) and ocular trefoil did not change significantly. In addition, topography-guided LASIK induced significantly fewer corneal total HOAs (P < .001), coma (P < .001), and trefoil (P = .020) than wavefront-optimized LASIK. Although both topography-guided LASIK and wavefront-optimized LASIK safely and effectively achieved the predicted refractive and visual outcomes, topography-guided LASIK induced fewer HOAs and significantly decreased ocular trefoil, corneal total HOAs, and coma.
- Open Access
- 1 December 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 12, 79-82
Case series: Use of stromal lenticule as patch graft
- 1 December 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 12, 79-82
Open AccessCase series: Use of stromal lenticule as patch graft
- Open Access
- 8 January 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 4
Impending extrusion of Ex-PRESS shunt treated by shunt-position adjustment: a case report
To report a case of impending extrusion of Ex-PRESS shunt treated by shunt-position adjustment. A 56-year-old Asian woman presented with impending extrusion and malposition of Ex-PRESS shunt in her left eye. The bleb of the left eye was shallow and diffuse. In the past, the patient was treated by Ex-PRESS shunt implantation under the scleral flap in both eyes. There had been no Ex-PRESS shunt-related complication in her right eye, and she reported no history of left-eye trauma. Based on these findings, we hypothesized that the source of the left-eye problem was a loosely fixed Ex-PRESS shunt spur. It was thought, furthermore, that this inadequate scleral resistance during the Ex-PRESS shunt implantation was due to the low scleral rigidity resulting from high myopia and insufficient maintenance of the anterior chamber. We proceeded to make an incision in the area adjacent to the Ex-PRESS shunt using a super sharp blade. The shunt was then pushed into the anterior chamber with forceps, and the spur was fixed firmly. Pushing the shunt to the anterior chamber was found to have been sufficient to fix it firmly. In fact, when the sclera was palpated with a sponge, aqueous outflow was observed with no shunt displacement. Postoperative intraocular pressure (IOP) was managed well, and the bleb had formed with diffuse, prominent shapes. The Ex-PRESS shunt was well sustained with good positioning. When an Ex-PRESS shunt operation is performed on a patient who shows a tendency for low scleral rigidity, shunt implantation should be accomplished carefully and with force adequate for firm spur fixation.
- 8 January 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 4
Open AccessImpending extrusion of Ex-PRESS shunt treated by shunt-position adjustment: a case report
To report a case of impending extrusion of Ex-PRESS shunt treated by shunt-position adjustment. A 56-year-old Asian woman presented with impending extrusion and malposition of Ex-PRESS shunt in her left eye. The bleb of the left eye was shallow and diffuse. In the past, the patient was treated by Ex-PRESS shunt implantation under the scleral flap in both eyes. There had been no Ex-PRESS shunt-related complication in her right eye, and she reported no history of left-eye trauma. Based on these findings, we hypothesized that the source of the left-eye problem was a loosely fixed Ex-PRESS shunt spur. It was thought, furthermore, that this inadequate scleral resistance during the Ex-PRESS shunt implantation was due to the low scleral rigidity resulting from high myopia and insufficient maintenance of the anterior chamber. We proceeded to make an incision in the area adjacent to the Ex-PRESS shunt using a super sharp blade. The shunt was then pushed into the anterior chamber with forceps, and the spur was fixed firmly. Pushing the shunt to the anterior chamber was found to have been sufficient to fix it firmly. In fact, when the sclera was palpated with a sponge, aqueous outflow was observed with no shunt displacement. Postoperative intraocular pressure (IOP) was managed well, and the bleb had formed with diffuse, prominent shapes. The Ex-PRESS shunt was well sustained with good positioning. When an Ex-PRESS shunt operation is performed on a patient who shows a tendency for low scleral rigidity, shunt implantation should be accomplished carefully and with force adequate for firm spur fixation.