Rupamanjari Majumder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Rupamanjari Majumder has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Luther
Max Planck Institute for Dynamics and Self-Organization, Biomedical Physics Group, Goettingen, Germany; University Medical Center Goettingen, Institute of Pharmacology and Toxicology, Goettingen, Germany; German Center for Cardiovascular Research partner site Lower Saxony, Goettingen, Germany; Institute for the Dynamics of Complex Systems, University of Goettingen, Goettingen, Germany
5 shared publications - Alexander V. Panfilov
Ghent University
4 shared publications - Barbara Ribeiro de Oliveira
Nantes Université, CNRS, INSERM, l’institut du thorax, F-44000 Nantes, France
3 shared publications - Daniel A. Pijnappels
Laboratory of Experimental Cardiology, Department of Cardiology, Heart Lung Center Leiden, Leiden University Medical Center
3 shared publications - Eberhard Bodenschatz
Max Planck Institute for Dynamics and Self-Organization (MPI-DS), Am Fassberg 17, 37077 Göttingen, Germany
3 shared publications - Isabelle Denjoy
Centre de Référence Maladies Cardiaques Héréditaires, Filière Cardiogen, Département de Rythmologie, Paris, France
3 shared publications
Latest Publications
- Open Access
Nationwide Functional Profiling Enables Clinical Reclassification of KCNH2 Variants in the French LQT2 Population
Background: The increasing use of genetic testing has identified thousands of KCNH2 variants associated with long QT syndrome type 2 (LQT2), yet most remain variants of uncertain significance (VUS). Translating functional abnormalities into clinically actionable evidence remains a major challenge. We established a nationwide functional genomics strategy to systematically characterize KCNH2 variants identified in the French LQT2 population and improve their clinical interpretation. Methods: We characterized 303 KCNH2 variants, including 201 VUS, using standardized high-throughput automated patch-clamp electrophysiology and complementary membrane trafficking assays. Nine electrophysiological parameters were integrated using MeTAL to predict variant-specific repolarization phenotypes under homozygous and heterozygous conditions. Modeled QTc values were compared with patient electrocardiographic data and variant-specific penetrance estimates. Functional evidence was calibrated against established benign and pathogenic variants using ClinGen-recommended categorical OddsPath and continuous likelihood-ratio approaches. Results: Multidimensional functional profiling revealed abnormalities not captured by current amplitude alone, identifying additional variants with clinically relevant repolarization defects. Among variants assessed under heterozygous conditions, MeTAL predictions showed 82.9% concordance with patient QTc phenotypes for ACMG class 5 variants, with apparent discordances partly consistent with incomplete penetrance. Continuous likelihood-ratio calibration demonstrated strong discrimination between established benign and pathogenic variants (AUC=0.936) and provided graded functional evidence for 76.1% of VUS. Integration of calibrated functional evidence into the ACMG/AMP framework enabled reclassification of 64 of 201 VUS (31.8%), including 7 as pathogenic, 46 as likely pathogenic, and 11 as likely benign. Conclusions: This nationwide study establishes a scalable framework integrating high-throughput electrophysiology, computational modeling, and clinical phenotyping to translate complex KCNH2 channel dysfunction into clinically interpretable evidence. The resulting reclassification of nearly one-third of VUS, together with the open-access HAMMER database, provides a resource to improve molecular diagnosis and risk assessment in LQT2.
Open AccessNationwide Functional Profiling Enables Clinical Reclassification of KCNH2 Variants in the French LQT2 Population
Background: The increasing use of genetic testing has identified thousands of KCNH2 variants associated with long QT syndrome type 2 (LQT2), yet most remain variants of uncertain significance (VUS). Translating functional abnormalities into clinically actionable evidence remains a major challenge. We established a nationwide functional genomics strategy to systematically characterize KCNH2 variants identified in the French LQT2 population and improve their clinical interpretation. Methods: We characterized 303 KCNH2 variants, including 201 VUS, using standardized high-throughput automated patch-clamp electrophysiology and complementary membrane trafficking assays. Nine electrophysiological parameters were integrated using MeTAL to predict variant-specific repolarization phenotypes under homozygous and heterozygous conditions. Modeled QTc values were compared with patient electrocardiographic data and variant-specific penetrance estimates. Functional evidence was calibrated against established benign and pathogenic variants using ClinGen-recommended categorical OddsPath and continuous likelihood-ratio approaches. Results: Multidimensional functional profiling revealed abnormalities not captured by current amplitude alone, identifying additional variants with clinically relevant repolarization defects. Among variants assessed under heterozygous conditions, MeTAL predictions showed 82.9% concordance with patient QTc phenotypes for ACMG class 5 variants, with apparent discordances partly consistent with incomplete penetrance. Continuous likelihood-ratio calibration demonstrated strong discrimination between established benign and pathogenic variants (AUC=0.936) and provided graded functional evidence for 76.1% of VUS. Integration of calibrated functional evidence into the ACMG/AMP framework enabled reclassification of 64 of 201 VUS (31.8%), including 7 as pathogenic, 46 as likely pathogenic, and 11 as likely benign. Conclusions: This nationwide study establishes a scalable framework integrating high-throughput electrophysiology, computational modeling, and clinical phenotyping to translate complex KCNH2 channel dysfunction into clinically interpretable evidence. The resulting reclassification of nearly one-third of VUS, together with the open-access HAMMER database, provides a resource to improve molecular diagnosis and risk assessment in LQT2.
- Open Access
MeTAL enables multiparametric risk prediction for human KCNH2 variants
Background: Clinical interpretation of missense variants in the hERG potassium channel encoded by the KCNH2 gene remains a major challenge in inherited arrhythmia syndromes. Functional studies often rely on a minimal set of channel properties, mainly current amplitude measurements, which do not capture the multidimensional nature of channel gating and its impact on ventricular repolarization. We developed a multiscale computational framework to quantitatively link multiparametric channel dysfunction to ECG phenotypes. Methods: We generated multiparametric electrophysiological profiles for KCNH2 variants using high-throughput patch-clamp, quantifying nine biophysical properties including conductance, voltage dependence, and gating kinetics. These parameters were incorporated into a modified formulation of I Kr embedded in a human ventricular electrophysiology model. The resulting framework, termed MeTAL (Multiscale-enriched Transformation and Analysis for Long-QT), produces physiologically calibrated pseudo-ECGs enabling quantitative evaluation of QT dynamics. We systematically analyzed the contribution of individual and combined gating parameters and applied the model to 41 KCNH2 variants across ACMG classes, comparing simulated QTc values with clinical data. Results: Multiparametric profiling revealed complex functional signatures in most variants, with concurrent gain- and loss-of-function effects affecting distinct gating processes. Simulations demonstrated that ventricular repolarization, though strongly determined by current amplitude, is substantially influenced by inactivation-related parameters, particularly the slope and voltage dependence of inactivation. Interaction analyses showed nonlinear relationships between gating parameters, explaining why variants with similar current density can produce divergent QT phenotypes. In heterozygous simulations, MeTAL reproduced clinically observed QTc distributions across variant classes and accurately predicted the repolarization regime (normal, long-QT, or short-QT) in most cases. Conclusions: Multiparametric integration of ion-channel function within a multiscale electrophysiological model enables mechanistic prediction of QT behavior beyond conductance-based metrics. This approach provides a scalable framework for interpretation of KCNH2 variants and solves the issue of risk stratification in inherited arrhythmia syndromes while offering new opportunities for variant-specific and pharmacological modeling of repolarization.
Open AccessMeTAL enables multiparametric risk prediction for human KCNH2 variants
Background: Clinical interpretation of missense variants in the hERG potassium channel encoded by the KCNH2 gene remains a major challenge in inherited arrhythmia syndromes. Functional studies often rely on a minimal set of channel properties, mainly current amplitude measurements, which do not capture the multidimensional nature of channel gating and its impact on ventricular repolarization. We developed a multiscale computational framework to quantitatively link multiparametric channel dysfunction to ECG phenotypes. Methods: We generated multiparametric electrophysiological profiles for KCNH2 variants using high-throughput patch-clamp, quantifying nine biophysical properties including conductance, voltage dependence, and gating kinetics. These parameters were incorporated into a modified formulation of I Kr embedded in a human ventricular electrophysiology model. The resulting framework, termed MeTAL (Multiscale-enriched Transformation and Analysis for Long-QT), produces physiologically calibrated pseudo-ECGs enabling quantitative evaluation of QT dynamics. We systematically analyzed the contribution of individual and combined gating parameters and applied the model to 41 KCNH2 variants across ACMG classes, comparing simulated QTc values with clinical data. Results: Multiparametric profiling revealed complex functional signatures in most variants, with concurrent gain- and loss-of-function effects affecting distinct gating processes. Simulations demonstrated that ventricular repolarization, though strongly determined by current amplitude, is substantially influenced by inactivation-related parameters, particularly the slope and voltage dependence of inactivation. Interaction analyses showed nonlinear relationships between gating parameters, explaining why variants with similar current density can produce divergent QT phenotypes. In heterozygous simulations, MeTAL reproduced clinically observed QTc distributions across variant classes and accurately predicted the repolarization regime (normal, long-QT, or short-QT) in most cases. Conclusions: Multiparametric integration of ion-channel function within a multiscale electrophysiological model enables mechanistic prediction of QT behavior beyond conductance-based metrics. This approach provides a scalable framework for interpretation of KCNH2 variants and solves the issue of risk stratification in inherited arrhythmia syndromes while offering new opportunities for variant-specific and pharmacological modeling of repolarization.
- Open Access
- 25 December 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (2)
SPARC: a structural pathogenicity algorithm for risk classification of hERG variants
Inherited mutations in the KCNH2 gene, which encodes the cardiac hERG potassium channel, are major contributors to arrhythmogenic syndromes such as long QT and short QT syndromes. However, clinical interpretation of the growing number of missense variants – many of which are classified as variants of uncertain significance (VUS) – remains a pressing challenge. Here, we present a semi-automated in silico pipeline for predicting hERG variant pathogenicity, acting as a binary classifier and integrating five structural metrics – residue volume, hydrophobicity, charge, steric clashes, and proximity to pathogenic hotspots – into a composite structural pathogenicity score (SPS) scaled from 1 to 5. Applied to 1727 hERG variants from ClinVar and from a French nationwide cohort, this binary classifier, termed SPARC, identified 260 variants as high risk of pathogenicity with SPS ≥3.25, of which a representative subset from the French cohort was functionally validated using high-throughput automated patch-clamp. Functional phenotyping confirmed the structural predictions, including for several VUS, demonstrating that comprehensive structural scoring can reliably stratify variant pathogenicity. This approach, benchmarked with Alpha Missense and Revel, offers a superior scalable, cost-effective pre-screening tool to guide clinical variant interpretation and prioritization for experimental validation.
- 25 December 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (2)
Open AccessSPARC: a structural pathogenicity algorithm for risk classification of hERG variants
Inherited mutations in the KCNH2 gene, which encodes the cardiac hERG potassium channel, are major contributors to arrhythmogenic syndromes such as long QT and short QT syndromes. However, clinical interpretation of the growing number of missense variants – many of which are classified as variants of uncertain significance (VUS) – remains a pressing challenge. Here, we present a semi-automated in silico pipeline for predicting hERG variant pathogenicity, acting as a binary classifier and integrating five structural metrics – residue volume, hydrophobicity, charge, steric clashes, and proximity to pathogenic hotspots – into a composite structural pathogenicity score (SPS) scaled from 1 to 5. Applied to 1727 hERG variants from ClinVar and from a French nationwide cohort, this binary classifier, termed SPARC, identified 260 variants as high risk of pathogenicity with SPS ≥3.25, of which a representative subset from the French cohort was functionally validated using high-throughput automated patch-clamp. Functional phenotyping confirmed the structural predictions, including for several VUS, demonstrating that comprehensive structural scoring can reliably stratify variant pathogenicity. This approach, benchmarked with Alpha Missense and Revel, offers a superior scalable, cost-effective pre-screening tool to guide clinical variant interpretation and prioritization for experimental validation.
- Open Access
- 19 November 2025
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 5, 1692372
Termination of figure-of-eight reentry via resonant feedback pacing
Sudden cardiac death (SCD) is often precipitated by reentrant arrhythmias such as ventricular tachycardia (VT) and ventricular fibrillation (VF), whose underlying dynamics are frequently sustained by spiral waves of electrical activity. Disrupting these waves can restore normal rhythm, but conventional low-energy pacing strategies are often ineffective in VF, where high-frequency, multi-wave interactions dominate. Resonant feedback-controlled antitachycardia pacing (rF-ATP), which times global electrical stimuli based on real-time feedback from the tissue, has been shown to robustly terminate single spirals under diverse conditions. However, its impact on interacting spiral waves—arguably a more realistic substrate for life-threatening arrhythmias—remains unexplored. Here, we use numerical simulations to investigate the effect of rF-ATP on figure-of-eight reentry, a clinically relevant configuration consisting of two counter-rotating spirals. We show that rF-ATP consistently terminates this pattern, regardless of feedback point location, through two distinct dynamical pathways: mutual collision of phase singularities or annihilation at inexcitable boundaries. We further demonstrate the method’s efficacy across variations in feedback point and spiral arrangement, indicating robustness to geometrical and positional heterogeneity. These results highlight rF-ATP as a promising low-energy intervention for complex reentrant structures and provide mechanistic insight into feedback-driven control of multi-core spiral wave dynamics in cardiac tissue.
- 19 November 2025
- Published by Frontiers Media SA in Frontiers in Network Physiology
- Vol. 5, 1692372
Open AccessTermination of figure-of-eight reentry via resonant feedback pacing
Sudden cardiac death (SCD) is often precipitated by reentrant arrhythmias such as ventricular tachycardia (VT) and ventricular fibrillation (VF), whose underlying dynamics are frequently sustained by spiral waves of electrical activity. Disrupting these waves can restore normal rhythm, but conventional low-energy pacing strategies are often ineffective in VF, where high-frequency, multi-wave interactions dominate. Resonant feedback-controlled antitachycardia pacing (rF-ATP), which times global electrical stimuli based on real-time feedback from the tissue, has been shown to robustly terminate single spirals under diverse conditions. However, its impact on interacting spiral waves—arguably a more realistic substrate for life-threatening arrhythmias—remains unexplored. Here, we use numerical simulations to investigate the effect of rF-ATP on figure-of-eight reentry, a clinically relevant configuration consisting of two counter-rotating spirals. We show that rF-ATP consistently terminates this pattern, regardless of feedback point location, through two distinct dynamical pathways: mutual collision of phase singularities or annihilation at inexcitable boundaries. We further demonstrate the method’s efficacy across variations in feedback point and spiral arrangement, indicating robustness to geometrical and positional heterogeneity. These results highlight rF-ATP as a promising low-energy intervention for complex reentrant structures and provide mechanistic insight into feedback-driven control of multi-core spiral wave dynamics in cardiac tissue.
- 20 November 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (21) , 218401
Photon-Scanning Approach to Control Spiral Wave Dynamics in the Heart
Self-organizing spiral electrical waves are produced in the heart during fatal cardiac arrhythmias. Controlling these waves is therefore an essential step in managing the disease. Here we present an effective method for controlling cardiac spiral waves using optogenetics. The method involves using photons to actively scan the surface of the heart for phase singularities. Once detected, these phase singularities are redirected to an inexcitable wall to be eliminated. Thus, spiral waves can be controlled in a double-blind fashion. We present two theoretical mechanisms with ex vivo validation.
- 20 November 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (21) , 218401
Photon-Scanning Approach to Control Spiral Wave Dynamics in the Heart
Self-organizing spiral electrical waves are produced in the heart during fatal cardiac arrhythmias. Controlling these waves is therefore an essential step in managing the disease. Here we present an effective method for controlling cardiac spiral waves using optogenetics. The method involves using photons to actively scan the surface of the heart for phase singularities. Once detected, these phase singularities are redirected to an inexcitable wall to be eliminated. Thus, spiral waves can be controlled in a double-blind fashion. We present two theoretical mechanisms with ex vivo validation.
- Open Access
- 2 July 2024
- Published by Elsevier in Biophysical Reports
- Vol. 4 (3) , 100170
In silico thermal control of spiral wave dynamics in excitable cardiac tissue
- 2 July 2024
- Published by Elsevier in Biophysical Reports
- Vol. 4 (3) , 100170
Open AccessIn silico thermal control of spiral wave dynamics in excitable cardiac tissue
- Open Access
- 1 March 2024
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 34 (3)
Efficient termination of cardiac arrhythmias using optogenetic resonant feedback pacing
Malignant cardiac tachyarrhythmias are associated with complex spatiotemporal excitation of the heart. The termination of these life-threatening arrhythmias requires high-energy electrical shocks that have significant side effects, including tissue damage, excruciating pain, and worsening prognosis. This significant medical need has motivated the search for alternative approaches that mitigate the side effects, based on a comprehensive understanding of the nonlinear dynamics of the heart. Cardiac optogenetics enables the manipulation of cellular function using light, enhancing our understanding of nonlinear cardiac function and control. Here, we investigate the efficacy of optically resonant feedback pacing (ORFP) to terminate ventricular tachyarrhythmias using numerical simulations and experiments in transgenic Langendorff-perfused mouse hearts. We show that ORFP outperforms the termination efficacy of the optical single-pulse (OSP) approach. When using ORFP, the total energy required for arrhythmia termination, i.e., the energy summed over all pulses in the sequence, is 1 mJ. With a success rate of 50%, the energy per pulse is 40 times lower than with OSP with a pulse duration of 10 ms. We demonstrate that even at light intensities below the excitation threshold, ORFP enables the termination of arrhythmias by spatiotemporal modulation of excitability inducing spiral wave drift.
- 1 March 2024
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 34 (3)
Open AccessEfficient termination of cardiac arrhythmias using optogenetic resonant feedback pacing
Malignant cardiac tachyarrhythmias are associated with complex spatiotemporal excitation of the heart. The termination of these life-threatening arrhythmias requires high-energy electrical shocks that have significant side effects, including tissue damage, excruciating pain, and worsening prognosis. This significant medical need has motivated the search for alternative approaches that mitigate the side effects, based on a comprehensive understanding of the nonlinear dynamics of the heart. Cardiac optogenetics enables the manipulation of cellular function using light, enhancing our understanding of nonlinear cardiac function and control. Here, we investigate the efficacy of optically resonant feedback pacing (ORFP) to terminate ventricular tachyarrhythmias using numerical simulations and experiments in transgenic Langendorff-perfused mouse hearts. We show that ORFP outperforms the termination efficacy of the optical single-pulse (OSP) approach. When using ORFP, the total energy required for arrhythmia termination, i.e., the energy summed over all pulses in the sequence, is 1 mJ. With a success rate of 50%, the energy per pulse is 40 times lower than with OSP with a pulse duration of 10 ms. We demonstrate that even at light intensities below the excitation threshold, ORFP enables the termination of arrhythmias by spatiotemporal modulation of excitability inducing spiral wave drift.
- Open Access
- 3 October 2022
- Published by Elsevier in Physics Open
- Vol. 13
Spiral- and scroll-wave dynamics in mathematical models for canine and human ventricular tissue with varying Potassium and Calcium currents
- 3 October 2022
- Published by Elsevier in Physics Open
- Vol. 13
Open AccessSpiral- and scroll-wave dynamics in mathematical models for canine and human ventricular tissue with varying Potassium and Calcium currents
- Open Access
- 16 June 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (6) , 064033
From Disorder to Normal Rhythm: Traveling-Wave Control of Cardiac Arrhythmias
Lethal cardiac arrhythmias often involve the occurrence of spiral waves, whose control is essential for the treatment of the disease. While high-voltage shock-based control methods rely on ensuring an abrupt electrical synchronization of the heart, low-energy techniques mostly cause drift-induced termination of these waves. In particular, such a drift can be induced by a spatiotemporal modulation of domain excitability in optogenetically modified cardiac tissue. Here we demonstrate a low-energy optogenetics-based approach to suppress spiral waves via their transient chaotization and rapid drift.
- 16 June 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (6) , 064033
Open AccessFrom Disorder to Normal Rhythm: Traveling-Wave Control of Cardiac Arrhythmias
Lethal cardiac arrhythmias often involve the occurrence of spiral waves, whose control is essential for the treatment of the disease. While high-voltage shock-based control methods rely on ensuring an abrupt electrical synchronization of the heart, low-energy techniques mostly cause drift-induced termination of these waves. In particular, such a drift can be induced by a spatiotemporal modulation of domain excitability in optogenetically modified cardiac tissue. Here we demonstrate a low-energy optogenetics-based approach to suppress spiral waves via their transient chaotization and rapid drift.
- Open Access
- 10 March 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 812535
A Mathematical Model for Electrical Activity in Pig Atrial Tissue
State of the art mathematical models are currently used to bridge the gap between basic research conducted in the laboratory and preclinical research conducted on large animals, which ultimately paves the way for clinical translation. In this regard, there is a great need for models that can be used alongside experiments for in-depth investigation and validation. One such experimental model is the porcine atrium, which is commonly used to study the mechanisms of onset and control of atrial fibrillation in the context of its surgical management. However, a mathematical model of pig atria is lacking. In this paper, we present the first ionically detailed mathematical model of porcine atrial electrophysiology, at body temperature. The model includes 12 ionic currents, 4 of which were designed based on experimental patch-clamp data directly obtained from literature. The formulations for the other currents are adopted from the human atrial model, and modified for porcine specificity based on our measured restitution data for different action potential characteristics: resting membrane potential, action potential amplitude, maximum upstroke velocity and action potential duration and different levels of membrane voltage repolarization. The intracellular Ca2+ dynamics follows the Luo-Rudy formulation for guinea pig ventricular cardiomyocytes. The resulting model represents “normal” cells which are formulated as a system of ordinary differential equations. We extend our model to two dimensions to obtain plane wave propagation in tissue with a velocity of 0.58 m/s and a wavelength of 8 cm. The wavelength reduces to 5 cm when the tissue is paced at 200 ms. Using S1-S2 cross-field protocol, we demonstrate in an 11.26 cm square simulation domain, the ability to initiate single spiral waves (rotation period ≃ 180 ms) that remain stable for more than 40 s. The spiral tip exhibits hypermeander. In agreement with previous experimental results using pig atria, our model shows that early repolarization is primarily driven by a calcium-mediated chloride current, IClCa, which is completely inactivated at high pacing frequencies. This is a condition that occurs only in porcine atria. Furthermore, the model shows spatiotemporal chaos with reduced repolarization.
- 10 March 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 812535
Open AccessA Mathematical Model for Electrical Activity in Pig Atrial Tissue
State of the art mathematical models are currently used to bridge the gap between basic research conducted in the laboratory and preclinical research conducted on large animals, which ultimately paves the way for clinical translation. In this regard, there is a great need for models that can be used alongside experiments for in-depth investigation and validation. One such experimental model is the porcine atrium, which is commonly used to study the mechanisms of onset and control of atrial fibrillation in the context of its surgical management. However, a mathematical model of pig atria is lacking. In this paper, we present the first ionically detailed mathematical model of porcine atrial electrophysiology, at body temperature. The model includes 12 ionic currents, 4 of which were designed based on experimental patch-clamp data directly obtained from literature. The formulations for the other currents are adopted from the human atrial model, and modified for porcine specificity based on our measured restitution data for different action potential characteristics: resting membrane potential, action potential amplitude, maximum upstroke velocity and action potential duration and different levels of membrane voltage repolarization. The intracellular Ca2+ dynamics follows the Luo-Rudy formulation for guinea pig ventricular cardiomyocytes. The resulting model represents “normal” cells which are formulated as a system of ordinary differential equations. We extend our model to two dimensions to obtain plane wave propagation in tissue with a velocity of 0.58 m/s and a wavelength of 8 cm. The wavelength reduces to 5 cm when the tissue is paced at 200 ms. Using S1-S2 cross-field protocol, we demonstrate in an 11.26 cm square simulation domain, the ability to initiate single spiral waves (rotation period ≃ 180 ms) that remain stable for more than 40 s. The spiral tip exhibits hypermeander. In agreement with previous experimental results using pig atria, our model shows that early repolarization is primarily driven by a calcium-mediated chloride current, IClCa, which is completely inactivated at high pacing frequencies. This is a condition that occurs only in porcine atria. Furthermore, the model shows spatiotemporal chaos with reduced repolarization.