Ryoji Iiduka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryoji Iiduka has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Wataru Ishii
Department of Emergency and Critical Care Medicine, Japanese Red Cross Society Kyoto Daini Hospital, 355-5 Haruobicho Kamigyoku, Kyoto, 602-8026, Japan
6 shared publications - Hiromichi Narumiya
Department of Emergency and Critical Care Medicine, Japanese Red Cross Kyoto Daini Hospital, Kyoto, Japan
5 shared publications - Kenji Kandori
Department of Emergency and Critical Care Medicine, Japanese Red Cross Society, Kyoto Daini Hospital, Kyoto, Japan
4 shared publications - Yohei Okada
Kyoto University
4 shared publications - Ayumu Tsuruoka
Department of Emergency and Critical Care Medicine, Kyoto Min-Iren Chuo Hospital, Kyoto, Japan
1 shared publication - Kaoru Koike
Department of Primary Care and Emergency Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
1 shared publication
Latest Publications
- 1 September 2020
- Published by Elsevier in Resuscitation
- Vol. 154, 129-130
Reply to: Coronavirus disease 2019 and ethical considerations for extracorporeal cardiopulmonary resuscitation
- 1 September 2020
- Published by Elsevier in Resuscitation
- Vol. 154, 129-130
Reply to: Coronavirus disease 2019 and ethical considerations for extracorporeal cardiopulmonary resuscitation
- 1 August 2020
- Published by Elsevier in Resuscitation
- Vol. 153, 6-7
Extracorporeal cardiopulmonary resuscitation should not be performed on confirmed or suspected COVID-19 patients
- 1 August 2020
- Published by Elsevier in Resuscitation
- Vol. 153, 6-7
Extracorporeal cardiopulmonary resuscitation should not be performed on confirmed or suspected COVID-19 patients
- Open Access
- 21 November 2019
- Published by Springer Nature in Surgical Case Reports
- Vol. 5 (1) , 1-6
Successful combination strategy of preoperative placement of an endoscopic nasopancreatic drainage catheter and pancreas preservation surgery for pancreatic injury with major pancreatic duct disruption: a case report
Background: The guidelines recommend pancreatic resection for grade III and IV pancreatic injuries. On the other hand, organ preservation is an important issue. Herein, we present the first case of pancreatic injury with major pancreatic duct (MPD) disruption that was treated with the combination of preoperative placement of endoscopic nasopancreatic drainage (ENPD) catheter and pancreas preservation surgery after endoscopic pancreatic stenting (EPS) failure. Case presentation: A 70-year-old female diagnosed with pancreatic injury was admitted to our hospital. She was hemodynamically stable. ERP revealed MPD disruption, and EPS failed. An ENPD catheter was placed preoperatively at the site of injury. During laparotomy, we identified a partial-thickness laceration in the pancreatic body. At the site of injury, the tip of the ENPD catheter was found; therefore, the patient was diagnosed with grade III pancreatic body injury with MPD disruption. The extent of crush was not severe, and we had no difficulty in identifying the distal MPD segment. We inserted the ENPD catheter into the distal MPD segment. The ruptured MPD and the laceration was sutured, then pancreatic resection was prevented. She was discharged on POD 56. Conclusion: The treatment strategy incorporated ERP, placement of an ENPD catheter preoperatively, and a simple surgery in a hemodynamically stable patient with pancreatic injury allows the pancreas and spleen to be preserved.
- 21 November 2019
- Published by Springer Nature in Surgical Case Reports
- Vol. 5 (1) , 1-6
Open AccessSuccessful combination strategy of preoperative placement of an endoscopic nasopancreatic drainage catheter and pancreas preservation surgery for pancreatic injury with major pancreatic duct disruption: a case report
Background: The guidelines recommend pancreatic resection for grade III and IV pancreatic injuries. On the other hand, organ preservation is an important issue. Herein, we present the first case of pancreatic injury with major pancreatic duct (MPD) disruption that was treated with the combination of preoperative placement of endoscopic nasopancreatic drainage (ENPD) catheter and pancreas preservation surgery after endoscopic pancreatic stenting (EPS) failure. Case presentation: A 70-year-old female diagnosed with pancreatic injury was admitted to our hospital. She was hemodynamically stable. ERP revealed MPD disruption, and EPS failed. An ENPD catheter was placed preoperatively at the site of injury. During laparotomy, we identified a partial-thickness laceration in the pancreatic body. At the site of injury, the tip of the ENPD catheter was found; therefore, the patient was diagnosed with grade III pancreatic body injury with MPD disruption. The extent of crush was not severe, and we had no difficulty in identifying the distal MPD segment. We inserted the ENPD catheter into the distal MPD segment. The ruptured MPD and the laceration was sutured, then pancreatic resection was prevented. She was discharged on POD 56. Conclusion: The treatment strategy incorporated ERP, placement of an ENPD catheter preoperatively, and a simple surgery in a hemodynamically stable patient with pancreatic injury allows the pancreas and spleen to be preserved.
- Open Access
- 3 May 2019
- Published by Springer Nature in Journal of Intensive Care
- Vol. 7 (1) , 27
The development and validation of a “5A” severity scale for predicting in-hospital mortality after accidental hypothermia from J-point registry data
Accidental hypothermia is a serious condition that requires immediate and accurate assessment to determine severity and treatment. Currently, accidental hypothermia is evaluated using the Swiss grading system which uses core body temperature and clinical findings; however, research has shown that core body temperature is not associated with in-hospital mortality in urban settings. Therefore, we developed and validated a severity scale for predicting in-hospital mortality among urban Japanese patients with accidental hypothermia. Data for this multi-center retrospective cohort study were obtained from the J-point registry. We included patients with accidental hypothermia who were admitted to an emergency department. The total cohort was divided into a development cohort and validation cohort, based on the location of each institution. We developed a logistic regression model for predicting in-hospital mortality using the development cohort and assessed its internal validity using bootstrapping. The model was then subjected to external validation using the validation cohorts. Among the 572 patients in the J-point registry, 532 were ultimately included and divided into the development cohort (N = 288, six hospitals, in-hospital mortality 22.0%) and the validation cohort (N = 244, six hospitals, in-hospital mortality 27.0%). The 5 “A” scoring system based on age, activities-of-daily-living status, near arrest, acidemia, and serum albumin level was developed based on the variables’ coefficients in the development cohort. In the validation cohort, the prediction performance was validated. Our “5A” severity scoring system could accurately predict the risk of in-hospital mortality among patients with accidental hypothermia.
- 3 May 2019
- Published by Springer Nature in Journal of Intensive Care
- Vol. 7 (1) , 27
Open AccessThe development and validation of a “5A” severity scale for predicting in-hospital mortality after accidental hypothermia from J-point registry data
Accidental hypothermia is a serious condition that requires immediate and accurate assessment to determine severity and treatment. Currently, accidental hypothermia is evaluated using the Swiss grading system which uses core body temperature and clinical findings; however, research has shown that core body temperature is not associated with in-hospital mortality in urban settings. Therefore, we developed and validated a severity scale for predicting in-hospital mortality among urban Japanese patients with accidental hypothermia. Data for this multi-center retrospective cohort study were obtained from the J-point registry. We included patients with accidental hypothermia who were admitted to an emergency department. The total cohort was divided into a development cohort and validation cohort, based on the location of each institution. We developed a logistic regression model for predicting in-hospital mortality using the development cohort and assessed its internal validity using bootstrapping. The model was then subjected to external validation using the validation cohorts. Among the 572 patients in the J-point registry, 532 were ultimately included and divided into the development cohort (N = 288, six hospitals, in-hospital mortality 22.0%) and the validation cohort (N = 244, six hospitals, in-hospital mortality 27.0%). The 5 “A” scoring system based on age, activities-of-daily-living status, near arrest, acidemia, and serum albumin level was developed based on the variables’ coefficients in the development cohort. In the validation cohort, the prediction performance was validated. Our “5A” severity scoring system could accurately predict the risk of in-hospital mortality among patients with accidental hypothermia.
- Open Access
- 1 January 2018
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 51 (C) , 368-371
Massive systemic arterial air embolism caused by an air shunt after blunt chest trauma
Introduction: Systemic arterial air embolism (SAAE) is a rare but fatal condition, with only a few cases reported, and the detailed etiology underlying SAAE remains unknown. We report a first case of massive SAAE after blunt chest injury, wherein the presence of traumatic air shunt was confirmed by direct observation during surgery. We also summarize our experience with six other SAAE cases. Presentation of case: A 68-year-old woman was admitted in a state of cardiac arrest after a fall. Emergency room thoracotomy determined complete transection of left main bronchus and left superior pulmonary vein. Postmortem computed tomography (CT) revealed full of air in the aortic arch, the descending aorta, and the great vessels. Therefore, one of the cause of death might be SAAE. Discussion: An air shunt after blunt chest trauma can cause SAAE, and clinical signs and operative findings can provide clues for possible SAAE. The bronchopulmonary vein fistula, the aortic injury and full-thickness myocardial injury have the potential to become traumatic air shunts. In cases with a coexisting air shunt, pneumothorax, lung contusions and positive-pressure ventilation can be risk factors for SAAE, as sources of air continually entering the systemic arterial circulation. Conclusion: SAAE is caused by an air shunt following trauma. Clinical signs and operative findings summarized in this case should aid in the recognition of possible SAAE. Highlights:
- 1 January 2018
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 51 (C) , 368-371
Open AccessMassive systemic arterial air embolism caused by an air shunt after blunt chest trauma
Introduction: Systemic arterial air embolism (SAAE) is a rare but fatal condition, with only a few cases reported, and the detailed etiology underlying SAAE remains unknown. We report a first case of massive SAAE after blunt chest injury, wherein the presence of traumatic air shunt was confirmed by direct observation during surgery. We also summarize our experience with six other SAAE cases. Presentation of case: A 68-year-old woman was admitted in a state of cardiac arrest after a fall. Emergency room thoracotomy determined complete transection of left main bronchus and left superior pulmonary vein. Postmortem computed tomography (CT) revealed full of air in the aortic arch, the descending aorta, and the great vessels. Therefore, one of the cause of death might be SAAE. Discussion: An air shunt after blunt chest trauma can cause SAAE, and clinical signs and operative findings can provide clues for possible SAAE. The bronchopulmonary vein fistula, the aortic injury and full-thickness myocardial injury have the potential to become traumatic air shunts. In cases with a coexisting air shunt, pneumothorax, lung contusions and positive-pressure ventilation can be risk factors for SAAE, as sources of air continually entering the systemic arterial circulation. Conclusion: SAAE is caused by an air shunt following trauma. Clinical signs and operative findings summarized in this case should aid in the recognition of possible SAAE. Highlights:
- Open Access
- 1 August 2017
- Published by Elsevier in Trauma & Case Reports
- Vol. 10, 1-3
Treatment for unstable pulmonary sequestration injury in patient with severe blunt trauma: A case report
- 1 August 2017
- Published by Elsevier in Trauma & Case Reports
- Vol. 10, 1-3
Open AccessTreatment for unstable pulmonary sequestration injury in patient with severe blunt trauma: A case report
- Open Access
- 3 July 2017
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 25 (1) , 63
Anatomical landmarks for safely implementing resuscitative balloon occlusion of the aorta (REBOA) in zone 1 without fluoroscopy
Resuscitative balloon occlusion of the aorta (REBOA) can maintain hemodynamic stability during hemorrhagic shock after a following torso injury, although inappropriate balloon placement may induce brain or visceral organ ischemia. External anatomical landmarks [the suprasternal notch (SSN) and xiphoid process (Xi)] are empirically used to implement REBOA in zone 1. We aimed to confirm if these landmarks were useful for determining a balloon catheter length for safe implementation of REBOA in zone 1 without using fluoroscopy. We selected 25 successive adult blunt trauma cases requiring contrast-enhanced chest/abdominal computed tomography (CT) treated at our emergency department (in an urban area of Kyoto city, Japan) between October 1, 2016 and January 31, 2017. We retrospectively evaluated anonymized CT images. We used three-dimensional multiplanar reconstructions to measure the length along the aorta’s central axis, from the bilateral common femoral arteries (FA) to the celiac trunk (CeT) (FA–CeT) and to the origin of the left subclavian artery (LSCA) (FA–LSCA). Volume-rendering reconstruction images were used to measure the external distance from common FAs to SSN (FA–SSN) and to Xi (FA–Xi). FA–LSCA was significantly longer than FA–SSN. FA–CeT was significantly shorter than FA–Xi. Based on these results, the REBOA balloon catheter should be shorter than FA–SSN, and longer than FA–Xi to avoid placement outside zone 1. The advantages of this method are that it can rapidly and easily predict a safe balloon catheter length, and it reflects each patient’s individual torso height. To safely implement REBOA, the balloon catheter length should be shorter than FA–SSN and longer than FA–Xi. We believe that these anatomical landmarks are good references for safe implementation of REBOA in zone 1 without radiographic guidance.
- 3 July 2017
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 25 (1) , 63
Open AccessAnatomical landmarks for safely implementing resuscitative balloon occlusion of the aorta (REBOA) in zone 1 without fluoroscopy
Resuscitative balloon occlusion of the aorta (REBOA) can maintain hemodynamic stability during hemorrhagic shock after a following torso injury, although inappropriate balloon placement may induce brain or visceral organ ischemia. External anatomical landmarks [the suprasternal notch (SSN) and xiphoid process (Xi)] are empirically used to implement REBOA in zone 1. We aimed to confirm if these landmarks were useful for determining a balloon catheter length for safe implementation of REBOA in zone 1 without using fluoroscopy. We selected 25 successive adult blunt trauma cases requiring contrast-enhanced chest/abdominal computed tomography (CT) treated at our emergency department (in an urban area of Kyoto city, Japan) between October 1, 2016 and January 31, 2017. We retrospectively evaluated anonymized CT images. We used three-dimensional multiplanar reconstructions to measure the length along the aorta’s central axis, from the bilateral common femoral arteries (FA) to the celiac trunk (CeT) (FA–CeT) and to the origin of the left subclavian artery (LSCA) (FA–LSCA). Volume-rendering reconstruction images were used to measure the external distance from common FAs to SSN (FA–SSN) and to Xi (FA–Xi). FA–LSCA was significantly longer than FA–SSN. FA–CeT was significantly shorter than FA–Xi. Based on these results, the REBOA balloon catheter should be shorter than FA–SSN, and longer than FA–Xi to avoid placement outside zone 1. The advantages of this method are that it can rapidly and easily predict a safe balloon catheter length, and it reflects each patient’s individual torso height. To safely implement REBOA, the balloon catheter length should be shorter than FA–SSN and longer than FA–Xi. We believe that these anatomical landmarks are good references for safe implementation of REBOA in zone 1 without radiographic guidance.
- Open Access
- 10 November 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 1-4
Lower limb ischemia caused by resuscitative balloon occlusion of aorta
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emergency procedure to manage severe hemorrhagic shock from torso injury but can cause severe ischemia of the lower extremities. However, lower extremity ischemia occurring as a complication of REBOA has been rarely reported. We describe the severe lower extremity ischemia caused by REBOA with a 12-Fr sheath in a small-built patient. The patient was a 16-year-old male who developed severe hemorrhagic shock due to abdominal blunt trauma. Following REBOA with a 12-Fr sheath on the right femoral artery, an emergency laparotomy and angiography to control the hemorrhage were performed. Twenty-eight hours after admission, suspecting lower extremity ischemia and compartment syndrome, we removed the sheath with a manual maneuver and performed fasciotomy. The limb ischemia was thus partially resolved. However, amputation was necessary because of ischemic necrosis on day 32. Our patient was physically small, and the diameter of his femoral artery on the contralateral site of sheath placement was also small. Therefore, disproportion of the sheath and femoral artery sizes may have caused the ischemic complication. Our experience highlights the importance of appropriate size selection for the sheath in line with the target vessel. We also recommend postoperative monitoring of limb perfusion in such cases with the use of near-infrared spectroscopy to facilitate the early detection of ischemia.
- 10 November 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 1-4
Open AccessLower limb ischemia caused by resuscitative balloon occlusion of aorta
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emergency procedure to manage severe hemorrhagic shock from torso injury but can cause severe ischemia of the lower extremities. However, lower extremity ischemia occurring as a complication of REBOA has been rarely reported. We describe the severe lower extremity ischemia caused by REBOA with a 12-Fr sheath in a small-built patient. The patient was a 16-year-old male who developed severe hemorrhagic shock due to abdominal blunt trauma. Following REBOA with a 12-Fr sheath on the right femoral artery, an emergency laparotomy and angiography to control the hemorrhage were performed. Twenty-eight hours after admission, suspecting lower extremity ischemia and compartment syndrome, we removed the sheath with a manual maneuver and performed fasciotomy. The limb ischemia was thus partially resolved. However, amputation was necessary because of ischemic necrosis on day 32. Our patient was physically small, and the diameter of his femoral artery on the contralateral site of sheath placement was also small. Therefore, disproportion of the sheath and femoral artery sizes may have caused the ischemic complication. Our experience highlights the importance of appropriate size selection for the sheath in line with the target vessel. We also recommend postoperative monitoring of limb perfusion in such cases with the use of near-infrared spectroscopy to facilitate the early detection of ischemia.
- Open Access
- 16 February 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 17
Damage control management of innominate artery injury with tracheostomy
Innominate artery injury is a rare, but catastrophic complication of tracheostomy. We present a case of severe hemorrhagic shock in a 79-year-old male with innominate artery injury that occurred during tracheostomy. Despite temporary innominate artery isolation, the regional forehead saturation was 60 % without laterality. Because adequate cerebral blood flow was apparently maintained through collateral flow, we ligated the innominate, right carotid, and subclavian arteries. We confirmed adequate blood flow to the brain and the right subclavian artery through collateral circulation after ligation using computed tomographic angiography. A damage control management, which involves ligating the injured innominate artery to arrest hemorrhage and monitoring regional forehead saturation for brain ischemia, can be a considerable procedure for the treatment of severe hemorrhagic shock due to innominate artery injury.
- 16 February 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 17
Open AccessDamage control management of innominate artery injury with tracheostomy
Innominate artery injury is a rare, but catastrophic complication of tracheostomy. We present a case of severe hemorrhagic shock in a 79-year-old male with innominate artery injury that occurred during tracheostomy. Despite temporary innominate artery isolation, the regional forehead saturation was 60 % without laterality. Because adequate cerebral blood flow was apparently maintained through collateral flow, we ligated the innominate, right carotid, and subclavian arteries. We confirmed adequate blood flow to the brain and the right subclavian artery through collateral circulation after ligation using computed tomographic angiography. A damage control management, which involves ligating the injured innominate artery to arrest hemorrhage and monitoring regional forehead saturation for brain ischemia, can be a considerable procedure for the treatment of severe hemorrhagic shock due to innominate artery injury.