Wei Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Zhou has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Sixiang Zhang
College of Mechanical Engineering, Hebei University of Technology, Tianjin, China
2 shared publications - Xu Zhang
School of Mechanical Engineering
2 shared publications - Hao Liu
Arizona College of Technology, Hebei University of Technology, China
1 shared publication - Qi Zhou
School of Electrical Engineering and Automation
1 shared publication - Xu Ma
Tianjin Key Laboratory of New Energy Power Conversion, Transmission and Intelligent Control, School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin 300384, China
1 shared publication - Yang Qi
Tianjin University of Technology and Education, Tianjin, China
1 shared publication
Latest Publications
- Open Access
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 994-999
Compare the Accuracy of the LSTM Algorithm and the Linear Regression Algorithm in Predicting Stock Prices
The movement of stock prices causes a lot of concern, because it directly affects the economic interests of investors as well as the macroeconomic policy of the country. The stock market is influenced by many factors and prices are difficult to predict. But stock price forecasting is crucial because accurate stock price predictions can assist investors in making wiser decisions and lowering the risks associated with their investments. Therefore, the study of stock price forecasting is of great value. The traditional stock prediction method has the problems of difficulty in feature extraction and low prediction accuracy. In order to solve these problems, this paper constructs a neural network model based on LSTM based on deep learning algorithm. In this paper, BYD (002594) and PingAn Bank (000001) in China stock market are selected and the two stocks are predicted using LSTM and traditional linear regression algorithm. The final predicted price and the actual price are plotted as a stock price trend over time to compare the accuracy of the two algorithms in predicting stock prices. The final experimental results show that the LSTM algorithm outperforms the linear regression algorithm in predicting stock prices.
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 994-999
Open AccessCompare the Accuracy of the LSTM Algorithm and the Linear Regression Algorithm in Predicting Stock Prices
The movement of stock prices causes a lot of concern, because it directly affects the economic interests of investors as well as the macroeconomic policy of the country. The stock market is influenced by many factors and prices are difficult to predict. But stock price forecasting is crucial because accurate stock price predictions can assist investors in making wiser decisions and lowering the risks associated with their investments. Therefore, the study of stock price forecasting is of great value. The traditional stock prediction method has the problems of difficulty in feature extraction and low prediction accuracy. In order to solve these problems, this paper constructs a neural network model based on LSTM based on deep learning algorithm. In this paper, BYD (002594) and PingAn Bank (000001) in China stock market are selected and the two stocks are predicted using LSTM and traditional linear regression algorithm. The final predicted price and the actual price are plotted as a stock price trend over time to compare the accuracy of the two algorithms in predicting stock prices. The final experimental results show that the LSTM algorithm outperforms the linear regression algorithm in predicting stock prices.
- Open Access
- 6 November 2020
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2020, 1-5
The Effect Analysis of Carrier Gas Flow Rate on the Rapid Gas Chromatographic Separation System
Odor pollution did not only disturb the human normal life but also aroused the attention of environmental researchers and environmental protection departments. Therefore, the research on odor detecting method and instrument is important to theory and application. On this basis, the self-developed microfluidic chip capillary column is used in our odor detecting system. In this paper, lead the chip column into the chromatography separation system, with its small size, high efficiency, easy integration, and other characteristics to replace the original traditional column. The chip column was used in many gas experiments for several typical VOCs. At different carrier gas flow rates, the baseline value, toluene response, and toluene and methyl sulfide mixed gas separation were compared to verify the experiment to determine the optimal carrier gas flow rate in accordance with its response and separation degree. Under the premise of ensuring column efficiency as high as possible, it is determined that the optimal carrier gas flow rate is 6 ml/min. This paper shows the most proper carrier gas flow rate of our odor detecting system with the self-developed microfluidic chip capillary column.
- 6 November 2020
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2020, 1-5
Open AccessThe Effect Analysis of Carrier Gas Flow Rate on the Rapid Gas Chromatographic Separation System
Odor pollution did not only disturb the human normal life but also aroused the attention of environmental researchers and environmental protection departments. Therefore, the research on odor detecting method and instrument is important to theory and application. On this basis, the self-developed microfluidic chip capillary column is used in our odor detecting system. In this paper, lead the chip column into the chromatography separation system, with its small size, high efficiency, easy integration, and other characteristics to replace the original traditional column. The chip column was used in many gas experiments for several typical VOCs. At different carrier gas flow rates, the baseline value, toluene response, and toluene and methyl sulfide mixed gas separation were compared to verify the experiment to determine the optimal carrier gas flow rate in accordance with its response and separation degree. Under the premise of ensuring column efficiency as high as possible, it is determined that the optimal carrier gas flow rate is 6 ml/min. This paper shows the most proper carrier gas flow rate of our odor detecting system with the self-developed microfluidic chip capillary column.
- Open Access
- 5 September 2018
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2018, 1-9
Development of a Novel Micro Photoionization Detector for Rapid Volatile Organic Compounds Measurement
The simulation of the gas flow field and electrostatic field in the photoionization detector by COMSOL was conducted based on principle investigation in the present study. Under the guidance of simulation results, structural optimization was carried out to significantly reduce the dead volume of the ionization chamber, and finally, the relationship between offset voltage and collection efficiency was obtained which led to a remarkable increase in the collection efficiency of charged ions in the photoionization detector. Then an ionization chamber with low interference and fast response was developed. Then experiment was performed with toluene as a VOCs gas under the condition of optimal gas flow rate of 50 ml, UV lamp ionization energy of 10.86 eV. The results showed that the ion collection efficiency reached 91% at a bias voltage of 150 V. Moreover, a preferred linearity of 99.99% was obtained, and a ppb level of LOD can be achieved. The determination results well-fitted the relationship between offset voltage and the response value obtained in the simulation.
- 5 September 2018
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2018, 1-9
Open AccessDevelopment of a Novel Micro Photoionization Detector for Rapid Volatile Organic Compounds Measurement
The simulation of the gas flow field and electrostatic field in the photoionization detector by COMSOL was conducted based on principle investigation in the present study. Under the guidance of simulation results, structural optimization was carried out to significantly reduce the dead volume of the ionization chamber, and finally, the relationship between offset voltage and collection efficiency was obtained which led to a remarkable increase in the collection efficiency of charged ions in the photoionization detector. Then an ionization chamber with low interference and fast response was developed. Then experiment was performed with toluene as a VOCs gas under the condition of optimal gas flow rate of 50 ml, UV lamp ionization energy of 10.86 eV. The results showed that the ion collection efficiency reached 91% at a bias voltage of 150 V. Moreover, a preferred linearity of 99.99% was obtained, and a ppb level of LOD can be achieved. The determination results well-fitted the relationship between offset voltage and the response value obtained in the simulation.