MKMurat Korkmaz

Murat Korkmaz

*This is an algorithmically generated author record based on publicly available information.

Murat Korkmaz has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Okan Ozkunt

    Istinye University Hospital, Department of Orthopedics and Traumatology, Istanbul, Turkey

    2 shared publications
  • Fatih Dikici

    Acibadem Atakent University Hospital, Department of Orthopedics and Traumatology, Istanbul, Turkey

    1 shared publication
  • Fatih Di̇kİcİ

    1 shared publication
  • Halil Can Gemalmaz

    Department of Orthopedics and Traumatology, Acibadem Atakent University Hospital, Istanbul, Turkey

    1 shared publication
  • Kerim Sariyilmaz

    Department of Orthopedics and Traumatology, Acibadem Atakent University Hospital, Istanbul, Turkey

    1 shared publication
  • Kerim Sarıyılmaz

    Acibadem Atakent University Hospital, Department of Orthopedics and Traumatology, Istanbul, Turkey

    1 shared publication

Latest Publications

  • Open Access

    Effectiveness of posterior structures in the development of proximal junctional kyphosis following posterior instrumentation: A biomechanical study in a sheep spine model

    by Murat Korkmaz, Turgut Akgul, Kerim Sarıyılmaz, Okan Ozkunt, Fatih Dikici, Onder Yazicioglu

    Introduction: Proximal junctional kyphosis e PJK has been defined by a 10 or greater increase in kyphosis at the proximal junction as measured by the Cobb angle from the caudal endplate of the uppermost instrumented vertebrae (UIV) to the cephalad endplate of the vertebrae 1 segments cranial to the UIV. In this biomechanical study, it is aimed to evaluate effects of interspinosus ligament complex distruption and facet joint degeneration on PJK development. Materials and methods: Posterior instrumentation applied between T2 e T7 vertebrae using pedicle screws to randomly selected 21 sheeps, divided into 3 groups. First group selected as control group (CG), of which posterior soft tissue and facet joints are protected. In second group (spinosus group, SG) interspinosus ligament complex which 1 segment cranial to UIV has been transected, and third group (faset group-FG) was applied facet joint excision. 25 N, 50 N, 100 N, 150 N and 200 N forces applied at frequency of 5 Hertz as 100 cycles axial to the samples. Then, 250 N, 275 N and 300 N forces applied static axially. Interspinosus distance, kyphosis angle and discus heights was measured in radiological evaluation. Abnormal PJK was defined by a proximal junctional angle greater than 100 and at least 100 greater than the corresponding preoperative measurement. Results: In CG group, average interspinosus distance was 6,6 ±1.54 mm and kyphosis angle was 2,2 ± 0.46 before biomechanical testing, and they were measured as 9,4 ± 1.21 mm and 3,3 ±0.44 respectively after forces applied to samples. In SG group, average interspinosus distance was 6,2 ± 1.72 mm and kyphosis angle was 2,7 ± 1.01 before experiment, and they were measured as 20,8 ± 5.66 mm and 15,1 ± 2.34 respectively after forces applied to samples. In FG group, average interspinosus distance was 4,8 ± 1.15 mm and kyphosis angle was 1 ± 4.14 before experiment, and they were measured as 11,1 ± 1:96 mm and 11 ± 2.87 respectively after forces applied to samples. In comparison to group CG, statistically significant junctional kyphosis was seen on both FG and SG group after statistical analysis. (p < 0.05). PJK was seen statistically significant more on SG group than FG group. (p < 0.05). Not any statistically significant difference was seen on measurement of disk distances among three groups. (p > 0.05) Conclusions: Protecting interspinosus ligament complex and facet joint unity during posterior surgical treatment for spine deformation is vital to prevent PJK development. Based on our literature review, this is the first biomechanical study that reveals interspinosus ligament complex are more effective on preventing PJK development than facet joints.


  • Open Access

    Quantitative comparison of a laterally misplaced pedicle screw with a re-directed screw. How much pull-out strength is lost?

    by Murat Korkmaz, Kerim Sariyilmaz, Okan Ozkunt, Halil Can Gemalmaz, Turgut Akgül, Mustafa Sungur, Fatih Di̇kİcİ, Murat Baydoğan

    Objective Redirecting of a laterally misplaced pedicle screw into the accurate position decreases the pull-out strength due to the reinsertion, lateral wall cortical perforation and widening of the pedicle hole. Thus, this biomechanical study was performed to quantitatively analyze the pullout strength of a redirected laterally misplaced pedicle screw into the accurate position. Methods Thirty pedicules of 15 bovine vertebrae were separated to 3 groups, according to the screw placement method: 1) standard flawless trajectory; 2) trajectory with lateral pedicle wall perforation; 3) trajectory with lateral wall perforation redirected to the standard trajectory. Samples were placed on a universal testing machine and pullout loads were measured. Kruskal-Wallis test was utilized within 95% confidence interval and p value <0.05 to test for the statistical significance. Results The mean pullout strength was 2891±654,2 N(1383-3814,5) in Group 1; 817,8±227,6 N(308,6-1144,9) in Group 2 and 2081,1±487,7 N(1583,5-2962,5) in Group 3. The results found out to be statistically significant (p<0.05). Inter-group comparisons revealed that lateral pedicle wall perforation significantly decreases the pullout strength (p<0.05) and redirection of the screw increases the strength (p0.05). Conclusion The results of this study confirm that pullout strength of pedicle screw decreases by approximately 71% when the lateral wall is perforated and decreases 28% after redirection to the accurate position. ER -