SŽSimona Žabčí­ková

Simona Žabčí­ková

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Simona Žabčí­ková has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Square wave voltammetry at carbon paste electrode modified with surfactant for alpha tocopheryl acetate determination in cosmetics

    by Simona Žabčí­ková, Arlinda Nallbani, Milan Sýs, Tomáš Mikysek, Libor Červenka

    The aim of this study was describe electrochemical properties of a carbon paste electrode (CPE) bulk modified with 30% (w/w) surfactant sodium dodecyl sulphate (CPE/SDS) and demonstrates its application in the determination of α‑tocopheryl acetate (α‑TAc), known as vitamin E acetate, in selected cosmetic products, especially body creams. In addition to anionic SDS, cationic hexadecylpyridinium chloride monohydrate (CPC) was also tested as possible modifier. It was found that selection of surfactant type and its content significantly affect an electrical conductivity and mechanical stability of these heterogeneous electroanalytical sensors in pure organic solvents. Under this study, it was found that CPC is a totally inappropriate mediator due to very high backgroundcurrent. Together with other lipophilic vitamins characterized by antioxidant activity (dominantly retionoids), this completely synthetic substance is widely used as significant cosmetic additive due its preservative properties. Monitoring of its content in cosmetic products is usually performed by high‑performance liquid chromatography (HPLC) with UV detection. This standard analytical protocol is always burdened with the complex and time‑consuming preparation of the sample before analysis. For that reason, robust and simple electroanalytical method based on anodic oxidation of the α‑TAc at CPE/SDS by square wave voltammetry (SWV) performed in pure organic electrolyte (99.8% acetonitrile containing 0.1 mol·L‑1 LiClO4) was developed. Moreover, simple dissolution of sample in supporting electrolyte using ultrasonic bath and subsequent filtering through a stacked filter included all the necessary procedures for sample preparation. The linear range from 0.1 to 1.2 mmol·L‑1and limit of detection 37 µmol·L‑1 were found at pulse amplitude 10 mV and frequency 10 Hz as optimum. In analysis of selected cosmetics, the developed electroanalytical method was not validated using comparison with standard HPLC. At least, the recovery was verified by analysis of model sample and value 95.8% was calculated.


  • Open Access

    Electrochemical Study and Determination of All-trans Retinol at Carbon Paste Electrode Modified by Surfactant

    by Simona Žabčíková, Tomáš Mikysek, Libor Červenka, Milan Sýs

    The oxidation mechanism of all-trans-retinol (vitamin A1) and its several esters in non-aqueous, aqueous organic mixture, and pure aqueous media was investigated by cyclic voltammetry. The oxidation occurred in several irreversible steps. The calculated highest density of electrons in retinoid molecules which are delocalized over carbon atoms of the five conjugated double bonds (C5-C14) was found in the part of the molecule involved in oxidation processes. The most sensitive oxidation peak (at +0.8 V vs. Ag/AgCl) was used for development of new direct voltammetric method based on differential pulse voltammetry for the determination of retinol at carbon paste electrode modified with surfactant sodium dodecyl sulfate (CPE/SDS). The results show that 30% (by mass) of modifier SDS exhibited optimal sensitivity and shape of voltammograms. Compared to commonly used glassy carbon electrode (GCE), the CPE/SDS showed significant progress in the retinol electroanalysis. The linear ranges for retinol determination were 1.5·10-6-1.8·10-4 M for CPE/SDS and 4.4·10-6-7.0·10-4 M for GCE with the detection limits of 1.3·10-6 and 4.6·10-7 M, respectively.


  • Open Access

    Comparison of adsorptive with extractive stripping voltammetry in electrochemical determination of retinol

    by Milan Sýs, Simona Žabčí­ková, Libor Červenka, Karel Vytřas

    Adsorptive stripping voltammetry (AdSV) of retinol at solid glassy carbon electrode (GCE), carbon paste electrode (CPE) covered by thin layer of multi-wall carbon nanotubes (CPE/MWCNTs) and carbon paste electrode covered by thin layer of single layer graphene (CPE/Graphene) was compared with an extractive stripping voltammetry (ExSV) into silicone oil (SO) as lipophilic binder of glassy carbon paste electrode (GCPE). All types of selected working electrodes were characterized by a scanning electron microscopy to determine overall morphology of electrode surfaces together with spatial arrangement of used carbon particles. The retinol, also known as vitamin A1, was chosen as a model analyte because it is the most biologically active representative of retinoids which are classified as a significant group of lipophilic vitamins. Based on this comparison, it was observed that electrochemical method with high sensitivity (ExSV at GPCE) is generally characterized by shorter linear range of the calibration curve than in case of AdSV at CPE/MWCNTs or CPE/Graphene. Unlike AdSV at solid GCE, all other tested electrochemical methods could represent suitable analytical tools for monitoring of retinoids in different types of foodstuffs. Especially, content of retinol up to tenths milligrams can be easily determined using ExSV. Additionally, negative interference of chemical species present in real samples is minimal in comparison with direct voltammetric methods performed in supporting electrolytes based on organic solvents due to application of accumulation step in "ex-situ" mode.


  • Open Access

    Presence of Arcobacter species in pet cats and dogs in the Czech Republic

    by M. Pejchalova, S. Zabcikova, L. Silhova, D. Silha, I. Brozkova, M. Haslova

    » Articles | Agricultural Journals


  • Open Access

    Adsorptive stripping voltammetry in lipophilic vitamins determination

    by Milan Sýs, Simona Žabčí­ková, Libor Červenka, Karel Vytřas

    The aim of this contribution was to check if adsorptive stripping differential pulse voltammetry (AdSDPV) is suitable tool for sensitive simultenous electrochemical detection of lipophilic vitamins. Retinol (vitamin A1), cholecalciferol (vitamin D3), α-tocopherol (vitamin E) and phylloquinone (vitamin K1) were selected as representatives. All electrochemical measurements were performed in two separate steps due to the lipophilic character of the analytes. In the first step, an accumulation of lipophilic vitamin on the surface of glassy carbon electrode (GCE) was done by immersing working electrode into the aqueous”‘acetonitrile solutions (50%, v/v) of each vitamin (50.0 µmol.L-1) at 400 rpm for 5 min. In the second one, differential pulse voltammetry of accumulated vitamins was performed in 0.01 mol.L-1 acetate (pH 4.5) buffer at potential step (Estep) 5 mV, potential of amplitude (Eampl) 25 mV, interval time (t) 0.1 s and scan rate (ν) 50 mV.s-1. It was observed that electrochemical behaviour of lipophilic vitamins adsorbed on surface of solid GCE in the aqueous electrolyte was very similar to those performed in organic/aqueous electrolyte in literature. Due to reversible electrochemical behaviour of vitamin K1 (phylloquinone/phyllohydroquinone redox couple), it was possible to detect all lipophilic vitamins only in one analysis. Observed values of peak potentials (Ep) were sufficiently different for their recognition which was confirmed by the analysis of real sample. The results obtained in this study showed that simultaneous determination of some lipophilic vitamins is possible requiring further optimization study. For this reason, it is necessary to understand this work as an initial step in simultaneous determination of lipophilic vitamins without application of any chromatographic technique.


  • Open Access

    Determination of ascorbic acid in pharmaceutical preparation and fruit juice using modified carbon paste electrode

    by Simona Žabčí­ková, Dai Long Vu, Libor Červenka, Vojtěch Tambor, Martina Vašatová

    Acrobic acid is key substance in the human metabolism and the rapid and accurate determination in food is of a great interest. Ascorbic acid is an electroactive compound, however poorly responded on the bare carbon paste electrodes. In this paper, brilliant cresyl blue and multi-walled carbon nanotubes were used for the modification of carbon paste electrode. Brilliant cresyl blue acts as a mediator improving the transition of electrons, whereas multiwalled carbon nanotubes increased the surface of the electrode. Both brilliant cresyl blue and multiwalled carbon nanotubes were added directly to the composite material. The electrochemical behavior of modified electode was determined in electrolyte at various pH, and the effect of the scan rate was also performed. It was shown that the electrochemical process on the surface of the modified carbon paste electrode was diffusion-controlled. The resulted modified carbon paste electrode showed a good electrocatalytic activity towards the oxidation of ascorbic acid at a reduced overpotential of +100 mV descreasing the risk of interferences. A linear response of the ascorbic acid oxidation current measured by the amperometry in the range of 0.1 - 350 µmol.L-1 was obtained applying the sensor for the standard solution. The limit of detection and limit of quantification was found to be 0.05 and 0.15 µmol.L-1, respectively. The novel method was applied for the determination of ascorbic acid in pharmaceutical vitamin preparation and fruit juice, and the results were in good agreement with the standard HPLC method. The presented modification of carbon paste electrode is suitable for the fast, sensitive and very accurate determination of ascorbic acid in fruit juices and pharmaceutical preparation.

  • Open Access

    Modified carbon paste electrode as a tool for the evaluation of oxidative stability of rapeseed oil

    by Simona Žabčí­ková, Libor Červenka

    Carbon paste electrode was used for evaluation of oxidative stability of rapeseed oil samples using cyclic voltammetry in 0.1 mol.L-1 HCl as a supporting electrolyte. Rapeseed oil samples were exposed to daylight and oxygen in open glass baker at the laboratory condition in order to obtain oils with accelerated primary and secondary products of oxidation. The oxidation status was determinated by peroxide value and p-anisidine value. Total oxidative stability was expressed as TOTOX index. The edible oils were used for preparation (modification) of the carbon paste composite material followed by the cyclic voltammetric measurement. Peroxide values significantly increased whereas p-anisinde value rather fluctuated during 40 days of storage in all the samples. Cyclic voltammograms showed anodic current peaks at 575 - 600 mV and cathodic current peaks at 400 - 425 mV. The oxidation and reduction waves diminished at pH ≥3.0 suggesting not only phenolic compounds contributed to the electrochemical characteristic of oil samples. The peroxide value or p-anisidine value did not correlate with oxidation or reduction peak currents at the potential 575 - 600 mV and 400 - 425 mV, respectively. Both cathodic and anodic currents increased with increasing TOTOX index exhibiting positive correlation with high Spearman correlation coefficient (r = 0.894 and r = 0.914 for anodic and cathodic current, respectively). Linear relationship was found for each sample individually. A caution has to be done when interpreting results since the correlation seems to be of oil sample specific. Nevertheless, the modified carbon paste electrode with rapeseed oil represents a suitable and alternative tool for determination of the oxidative state of edible oils without use of organic solvents.