DSDingjie Suo

Dingjie Suo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dingjie Suo has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Flexible Microneedle Array Electrode with a High Signal-to-Noise Ratio for Surface Bioelectrical Signal Recording

    by Bo Jiang, Ye Wang, Ruiqing Li, Yan Zhou, Lihua Ma, Dingjie Suo, Guangying Pei

    Microneedle array (MNA) electrodes have garnered significant attention for their capacity to record high-fidelity surface bioelectrical signals over extended periods and convenience. However, accuracy limitations in 3D-printed metal MNA electrodes, particularly concerning surface roughness and insufficient tip sharpness, have been reported. Additionally, the prevalent use of nonporous metal substrates often results in poor flexibility. This study proposes a novel MNA electrode featuring a lightweight flexible substrate and sharp, smooth microneedles. Utilizing micron-level metal 3D printing with 316L stainless steel, we fabricated the electrodes in a single step. We evaluated the MNA electrode-skin interface impedance via frequency sweep and assessed mechanical properties using porcine skin, followed by the collection and analysis of bioelectrical signals. The results demonstrate that the contact impedance of the MNA electrode is comparable to that of standard gold cup electrodes, with validated flexibility and strength. Furthermore, the MNA electrodes achieved a high signal-to-noise ratio and minimal motion artifacts during recording, thereby enhancing both comfort and signal quality. The efficient production process facilitates the broader application of metal MNA electrodes.


  • Precise Manipulation of Bubble Cavitation and Blood–Brain Barrier Modulation using Temporal Interference Ultrasound

    by Jie Jin, Zhenxiang Ji, Zhetao Shangguan, Tianyi Yan, Shengyou Qian, Dingjie Suo

    Objective: To determine whether temporal interference (TI) ultrasound can enhance microbubble (MB) cavitation and provide transient modulation of blood–brain barrier (BBB) permeability. Impact Statement: By integrating a time-dependent multiphysics MB–vessel model with in vivo validation, this study links TI-enhanced cavitation dynamics to vessel-wall mechanical responses and a transient BBB permeability window, providing a mechanistic basis for pressure-efficient ultrasound-mediated brain delivery. Introduction: Focused ultrasound combined with MBs can transiently increase BBB permeability, but reliable control of cavitation intensity and post-sonication barrier recovery remains a key challenge for safe and effective brain delivery. Methods: A fluid–solid coupled MB–vessel model was used to evaluate MB dynamics, vessel-wall normal and shear stresses, porosity, acoustic-pressure dependence, and the influence of non-Newtonian blood rheology under 1.0 MHz single-frequency and 1.0 + 0.8 MHz TI excitation. In vivo Evans blue experiments in mice were then used to compare BBB opening across pressure levels and to characterize the recovery profile from 0.5 to 12 h after 0.3-MPa TI sonication. Results: Ultrasound-driven MB oscillation and collapse increased vessel-wall stress and modeled porosity. Compared with single-frequency ultrasound, TI excitation promoted earlier MB instability and collapse and produced stronger vessel-wall mechanical responses under energy-equivalent acoustic exposure conditions. In vivo, Evans blue extravasation increased with the reference pressure amplitude and showed higher mean values following TI ultrasound, with a significant between-mode difference at 0.5 MPa. After 0.3-MPa TI sonication, extravasation progressively decreased from 0.5 to 12 h, consistent with a transient BBB permeability increase. Non-Newtonian rheology altered the local shear environment but had limited effects on peak normal stress and porosity within the simulated time window. Conclusion: TI ultrasound enhances MB-mediated BBB opening under energy-normalized acoustic exposure conditions while producing a time-limited increase in permeability, supporting its further development for temporally controlled brain delivery.

  • Open Access

    The mouse motor cortex stimulation via non-invasive temporal interference transcranial focused ultrasound with microbubbles

    by Jie Jin, Xinze Liu, Zhenxiang Ji, Chenxuan Wu, Yuting Han, Quanrong Jing, Jian Zhang, Wei Li, Tianyi Yan, Hui Jing, et al.

  • Open Access

    Enhanced Brain-Controlled Mobile Robot Based on SE-VEP Paradigm With Single Stimulus

    by Tianyi Yan, Zhiyuan Ming, Yilun Huang, Ziyu Liu, Qiming Chen, Deyu Zhang, Mengzhen Liu, Dingjie Suo, Jian Zhang, Siyu Liu

    Brain–computer interface (BCI) systems based on steady-state visually evoked potentials (SSVEPs) have been widely adopted because of their efficiency and accuracy. However, the traditional SSVEP method has limitations, including visual fatigue and interference between different stimuli. To address these issues, a new BCI paradigm, namely, a spatial encoding–visually evoked potential (SE-VEP) model, is proposed in this work. This paradigm involves deploying four target points to implement gaze restrictions around a stimulus block and optimizing the locations of these target points through offline data acquisition. This design facilitates electroencephalogram (EEG) encoding for four instructions while using only one stimulus block. Data with varying eccentricities are classified using the Riemann kernel-based support vector machine (R-SVM) approach, which achieves a classification accuracy of up to 86.11%. As the eccentricity increases, the classification accuracy initially increases but subsequently decreases. By evaluating the information transfer rate (ITR), the optimal time window length for online BCIs is determined to be 1.2 s. Additionally, an online brain-controlled robotic virtual system is developed to validate the feasibility of the proposed paradigm for online brain–computer interface applications. The results confirm the effectiveness of the proposed paradigm in implementing an online BCI control system. An evaluation conducted with scales and the information transfer rate for a single stimulus (ITRSS) indicates that compared with the traditional BCI system, the proposed paradigm yields greater reductions in user fatigue (2.8 ± 0.5 vs. 4.1 ± 0.6) and stimulus block utilization (24.6 ± 2.3 vs. 8.2 ± 1.1 bits/min).


  • A Novel Nonlinear Smooth Controller for a Brain-Controlled Driving System in Complex Driving Scenarios

    by Tianyi Yan, Siyu Liu, Mengzhen Liu, Deyu Zhang, Zhiyuan Ming, Lingfei Ma, Jiawei Luo, Ziyu Liu, Qiming Chen, Tiantian Liu, et al.

    With the rapid advancement of technology, brain-controlled driving (BCD) has emerged as a contemporary focal point of research in academia and industry. BCD refers to the application of brain-machine interface (BMI) technology to driving, where control commands from the human brain are decoded by BMI technology and used to assist in the control of vehicles. However, existing BCD systems display inadequate performance in joint lateral and longitudinal control, and BCD systems in complex driving scenarios with other vehicles have not been studied. In this study, a nonlinear smooth controller is proposed, and a BCD system for complex driving scenarios is developed based on it. First, the BCD system is built from three modules, namely, the vehicle module, the BMI module and the controller module. Subsequently, the nonlinear smooth controller is developed based on the BMI controller, the proximal policy optimization (PPO) controller, and the self-adaptive collaborative (SAC) controller. The SAC controller is designed based on a sigmoid function to achieve nonlinear smoothness in the process of allocating control authority between the PPO controller and the BMI controller. The results of online driving experiments demonstrate that the proposed controller is better equipped to handle complex driving scenarios, exhibiting superior performance, heightened safety, and improved user experience compared to the PPO controller and BMI controller. This study holds significant value in advancing the practicality of BCD and providing a foundation for future research on BMI control.


  • Comparing Wired and Wireless Optogenetic Control Systems: Impact on Behavior and Efficiency

    by Hongzhen Pan, Yitong Zhang, Yiran Lang, Dingjie Suo, Chunyu Zhang, Jian Zhang

  • Open Access

    Amplitude of Intracranial Induced Electric Fields Does Not Linearly Decrease with Age: A Computational Study of Anatomical Effects in Adults

    by Jianxu Zhang, Zilong Yan, Anshun Kang, Jian Ouyang, Lihua Ma, Xinyue Wang, Jinglong Wu, Dingjie Suo, Shintaro Funahashi, Wei Meng, et al.

    Transcranial electrical stimulation, as a means of neural modulation, is increasingly favored by researchers. The distribution and magnitude of the electric field generated within the brain may directly affect the results of neural modulation. Therefore, it is important to clarify the change trend of the cortical electric field and the determinants of the induced electric field in the endodermis at different ages during the adult life cycle. In this study, we used SimNIBS software to perform MR image segmentation and realistic head model reconstruction on 476 individuals (aged 18 to 88 years old) and calculated the cortical electric field of four electrode montages commonly used in cognitive tasks. We divided all participants into groups by age with a span of 10 years for each group and compared the electric field distribution patterns, electric field intensities, and focalities of the cortexes and regions of interest related to cognitive tasks within groups. The degree of influence of global and local anatomical parameters on the electric field was analyzed using a stepwise regression model. The results showed that, in the cortexes and regions of interest, the variability of electric field distribution patterns was highest in adolescents (80 years old). Moreover, throughout the adult lifespan, the electric field induced by transcranial electrical stimulation did not decrease linearly with age but rather presented a U-shaped pattern. In terms of the entire adult life cycle, compared with global anatomical parameters (intracranial brain tissue volume), local anatomical parameters (such as scalp or skull thickness below the electrode) have a greater impact on the amplitude of the intracranial electric field. Our research results indicated that it is necessary to consider the effects caused by different brain tissues when using transcranial electrical stimulation to modulate or treat individuals of different ages.


  • Open Access

    Transcranial focused ultrasound precise neuromodulation: a review of focal size regulation, treatment efficiency and mechanisms

    by Jie Jin, Guangying Pei, Zhenxiang Ji, Xinze Liu, Tianyi Yan, Wei Li, Dingjie Suo

    Ultrasound is a mechanical wave that can non-invasively penetrate the skull to deep brain regions to activate neurons. Transcranial focused ultrasound neuromodulation is a promising approach, with the advantages of noninvasiveness, high-resolution, and deep penetration, which developed rapidly over the past years. However, conventional transcranial ultrasound’s spatial resolution is low-precision which hinders its use in precision neuromodulation. Here we focus on methods that could increase the spatial resolution, gain modulation efficiency at the focal spot, and potential mechanisms of ultrasound neuromodulation. In this paper, we summarize strategies to enhance the precision of ultrasound stimulation, which could potentially improve the ultrasound neuromodulation technic.


  • Open Access

    Ultrasound transducers with both imaging and power output capabilities by anti-matching at backing layers

    by Yiqi Cai, Lijun Xu, Teng Zhang, Dingjie Suo, Jianguo Ma

    Precise ultrasound therapy requires long-term power output and imaging guidance. However, traditional therapeutic transducers do not have imaging capabilities due to the low bandwidth and long ringing. Whereas for a diagnostic transducer, 20%–30% of the energy is dissipated as heat in the backing layer, resulting in degradation of the transducer under high duty cycle and high voltage excitation. Therefore, the transducers with both power output and imaging capabilities are unmet demands for precise ultrasonic treatment. To address this problem, we propose an ultrasound transducer with both imaging and power output capabilities. An anti-matching layer is designed at the position of the backing layer of the transducer, which reflects the backward ultrasound waves to forward waves. Therefore, the majority of the energy is transmitted efficiently and little energy is dissipated in the backing layer. Finite element simulations demonstrated that a double-layer anti-matching design reflects 99.8% of the backward energy, resulting in an insertion loss of −27.7 dB. The performance was validated by a transducer prototype with transmission measurement using hydrophone and pulse-echo test. This design of transducers with both imaging and power output capabilities indicates a promising application of self-guided ultrasound therapy.


  • Resting-State Functional MRI of Healthy Adults: Temporal Dynamic Brain Coactivation Patterns

    by Tiantian Liu, Li Wang, Dingjie Suo, Jian Zhang, Kexin Wang, Jue Wang, Duanduan Chen, Tianyi Yan

    Temporal dynamic changes of the aging brain with resting-state functional MRI demonstrated lower flexibility of the frontoparietal network and compensatory higher transitions between the default mo... Background The aging brain is typically associated with aberrant interactions of large-scale intrinsic networks. However, the dynamic variation of these networks’ coactivation or deactivation acros...