RMRinaldo Marzaioli

Rinaldo Marzaioli

*This is an algorithmically generated author record based on publicly available information.

Rinaldo Marzaioli has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transaxillary robotic-assisted thyroid surgery: technique and results of a preliminary experience on the Da Vinci Xi platform

    by Francesco Paolo Prete, Rinaldo Marzaioli, Serafina Lattarulo, Daniele Paradies, Graziana Barile, Maria Vittoria D’aDdetta, Giovanni Tomasicchio, Angela Gurrado, Angela Pezzolla

    Robotic thyroidectomy by transaxillary approach (RATS) is regarded as a feasible and safe alternative procedure in selected patients with benign disease or thyroid cancer of low risk, facilitating thyroidectomy with respect to conventional endoscopic approach and offering improved cosmetic results. The Da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) presents technical advantages over its previous generations, including overhead docking, more compact robotic arms, extended range of motion, and ability for camera to be docked in any arm. This construct supports dissection in smaller spaces with less arm interference and improved view. We present an initial experience of RATS on DVSS Xi in an academic Centre in Italy. We conducted a prospective observational study, involving patients with thyroid disease and treated between April 2016 and January 2018. A modified thyroidectomy retractor (Modena retractor, CEATEC Medizintechnik, Germany) was used to lift a musculocutaneous flap and operate gasless. Instrument placement was recorded for each procedure. Each procedure description was broken down into three phases, creation of working space, machine docking with instrument positioning and endoscopic operating technique. Duration of cases was recorded. Patients selected were young women, BMI < 30, thyroid nodule < 5 cm, cytology TIR2 to TIR4 (TIR4:only nodules < 1 cm diameter). Twelve RATS were performed within the learning curve for the robotic technique, 10 lobectomies and 2 total thyroidectomies. No patients required reintervention. Mean duration of surgery was 198.9 min for lobectomy and 210 for thyroidectomy. The same surgical team performed all procedures. No patients presented surgery-related complications, mean stay was 3 days. Decrease in operating time was observed after 8 cases along with more precise preparation of working space. Four arms were used in the first 10 procedures then only three. No recurrent laryngeal nerve dysfunction, no seroma or haematoma were recorded. One patient had transient hypocalcaemia after total thyroidectomy. Since the early phases of a preliminary experience RATS appeared a safe alternative to open thyroidectomy. Uptake of technique was quick on Xi platform with few technical tweaks over techniques described for Si machines. Careful patient selection is crucial. Retrospectively registered on 20 july 2018 . Trial registration number: researchregistry4272. The Research Registry: https://www.researchregistry.com/browse-the-registry#home/registrationdetails/5b517f08dbc2045aefd7f9b4/


  • Top Cited Papers
    Open Access

    A systematic review on the use of topical hemostats in trauma and emergency surgery

    by Osvaldo Chiara, Stefania Cimbanassi, Giovanni Bellanova, Massimo Chiarugi, Andrea Mingoli, Giorgio Olivero, Sergio Ribaldi, Gregorio Tugnoli, Silvia Basilicò, Francesca Bindi, et al.

    A wide variety of hemostats are available as adjunctive measures to improve hemostasis during surgical procedures if residual bleeding persists despite correct application of conventional methods for hemorrhage control. Some are considered active agents, since they contain fibrinogen and thrombin and actively participate at the end of the coagulation cascade to form a fibrin clot, whereas others to be effective require an intact coagulation system. The aim of this study is to provide an evidence-based approach to correctly select the available agents to help physicians to use the most appropriate hemostat according to the clinical setting, surgical problem and patient’s coagulation status. The literature from 2000 to 2016 was systematically screened according to PRISMA [Preferred Reporting Items for Systematic Reviews and Meta-Analyses] protocol. Sixty-six articles were reviewed by a panel of experts to assign grade of recommendation (GoR) and level of evidence (LoE) using the GRADE [Grading of Recommendations Assessment, Development and Evaluation] system, and a national meeting was held. Fibrin adhesives, in liquid form (fibrin glues) or with stiff collagen fleece (fibrin patch) are effective in the presence of spontaneous or drug-induced coagulation disorders. Mechanical hemostats should be preferred in patients who have an intact coagulation system. Sealants are effective, irrespective of patient’s coagulation status, to improve control of residual oozing. Hemostatic dressings represent a valuable option in case of external hemorrhage at junctional sites or when tourniquets are impractical or ineffective. Local hemostatic agents are dissimilar products with different indications. A knowledge of the properties of each single agent should be in the armamentarium of acute care surgeons in order to select the appropriate product in different clinical conditions.