Xi Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xi Yu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chang Liu
College of Computer Science, Chengdu University, Chengdu 610106, China
2 shared publications - Abdelaziz Bouras
Qatar University
1 shared publication - Aicha Sekhari
DISP Laboratory, University of Lumière Lyon 2 2 , Bâtiment Léonard de Vinci, 21 Ave. Jean Capelle, 69621 Villeurbanne
1 shared publication - Antoine Nongaillard
University of Lille, Villeneuve-d'Ascq, France
1 shared publication Gao ChaoBang
School of Computer Science, Chengdu University, Chengdu 610106, China ; Key Laboratory of Pattern Recognition and Intelligent Information Processing of Sichuan, Chengdu, China
1 shared publication- Jian Zhang
School of Physics and Electronic Engineering, Sichuan Normal University, Chengdu, China
1 shared publication
Latest Publications
- Open Access
- 25 August 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 1-23
Fusing multi-scale information in convolution network for MR image super-resolution reconstruction
Magnetic resonance (MR) images are usually limited by low spatial resolution, which leads to errors in post-processing procedures. Recently, learning-based super-resolution methods, such as sparse coding and super-resolution convolution neural network, have achieved promising reconstruction results in scene images. However, these methods remain insufficient for recovering detailed information from low-resolution MR images due to the limited size of training dataset. To investigate the different edge responses using different convolution kernel sizes, this study employs a multi-scale fusion convolution network (MFCN) to perform super-resolution for MRI images. Unlike traditional convolution networks that simply stack several convolution layers, the proposed network is stacked by multi-scale fusion units (MFUs). Each MFU consists of a main path and some sub-paths and finally fuses all paths within the fusion layer. We discussed our experimental network parameters setting using simulated data to achieve trade-offs between the reconstruction performance and computational efficiency. We also conducted super-resolution reconstruction experiments using real datasets of MR brain images and demonstrated that the proposed MFCN has achieved a remarkable improvement in recovering detailed information from MR images and outperforms state-of-the-art methods. We have proposed a multi-scale fusion convolution network based on MFUs which extracts different scales features to restore the detail information. The structure of the MFU is helpful for extracting multi-scale information and making full-use of prior knowledge from a few training samples to enhance the spatial resolution.
- 25 August 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 1-23
Open AccessFusing multi-scale information in convolution network for MR image super-resolution reconstruction
Magnetic resonance (MR) images are usually limited by low spatial resolution, which leads to errors in post-processing procedures. Recently, learning-based super-resolution methods, such as sparse coding and super-resolution convolution neural network, have achieved promising reconstruction results in scene images. However, these methods remain insufficient for recovering detailed information from low-resolution MR images due to the limited size of training dataset. To investigate the different edge responses using different convolution kernel sizes, this study employs a multi-scale fusion convolution network (MFCN) to perform super-resolution for MRI images. Unlike traditional convolution networks that simply stack several convolution layers, the proposed network is stacked by multi-scale fusion units (MFUs). Each MFU consists of a main path and some sub-paths and finally fuses all paths within the fusion layer. We discussed our experimental network parameters setting using simulated data to achieve trade-offs between the reconstruction performance and computational efficiency. We also conducted super-resolution reconstruction experiments using real datasets of MR brain images and demonstrated that the proposed MFCN has achieved a remarkable improvement in recovering detailed information from MR images and outperforms state-of-the-art methods. We have proposed a multi-scale fusion convolution network based on MFUs which extracts different scales features to restore the detail information. The structure of the MFU is helpful for extracting multi-scale information and making full-use of prior knowledge from a few training samples to enhance the spatial resolution.
- Open Access
- 21 April 2016
- Published by Springer Nature
- p. 56-65
An Environmental Burden Shifting Approach to Re-evaluate the Environmental Impacts of Products
- 21 April 2016
- Published by Springer Nature
- p. 56-65
Open AccessAn Environmental Burden Shifting Approach to Re-evaluate the Environmental Impacts of Products
- Open Access
- 12 October 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-11
A MRI Denoising Method Based on 3D Nonlocal Means and Multidimensional PCA
Recently nonlocal means (NLM) and its variants have been applied in the various scientific fields extensively due to its simplicity and desirable property to conserve the neighborhood information. The two-stage MRI denoising algorithm proposed in this paper is based on 3D optimized blockwise version of NLM and multidimensional PCA (MPCA). The proposed algorithm takes full use of the block representation advantageous of NLM3D to restore the noisy slice from different neighboring slices and employs MPCA as a postprocessing step to remove noise further while preserving the structural information of 3D MRI. The experiments have demonstrated that the proposed method has achieved better visual results and evaluation criteria than 3D-ADF, NLM3D, and OMNLM_LAPCA.
- 12 October 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-11
Open AccessA MRI Denoising Method Based on 3D Nonlocal Means and Multidimensional PCA
Recently nonlocal means (NLM) and its variants have been applied in the various scientific fields extensively due to its simplicity and desirable property to conserve the neighborhood information. The two-stage MRI denoising algorithm proposed in this paper is based on 3D optimized blockwise version of NLM and multidimensional PCA (MPCA). The proposed algorithm takes full use of the block representation advantageous of NLM3D to restore the noisy slice from different neighboring slices and employs MPCA as a postprocessing step to remove noise further while preserving the structural information of 3D MRI. The experiments have demonstrated that the proposed method has achieved better visual results and evaluation criteria than 3D-ADF, NLM3D, and OMNLM_LAPCA.