Takahiro Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takahiro Sato has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ayumu Kusano
Department of Pharmacy, Toho University Omori Medical Center, 6-11-1 Omori-nishi, Ota-ku, Tokyo 143-8541, Japan
1 shared publication C. Kajiwara
Department of Microbiology and Infectious Diseases, Toho University School of Medicine, Tokyo, Japan
1 shared publicationH. Murakami
Department of Clinical Laboratories, Toho University Omori Medical Centre, Tokyo, Japan
1 shared publication- Hayato Ohashi
Department of Pharmacy, Toho University Omori Medical Center, Tokyo 143-8541, Japan
1 shared publication - Itsuki Kimura
Department of Pharmacy, Toho University Omori Medical Center, 6-11-1 Omori-nishi, Ota-ku, Tokyo 143-8541, Japan
1 shared publication J. Hisatsune
National Institute of Infectious Diseases, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 8 June 2023
- Published by Elsevier in Journal of Hospital Infection
- Vol. 139, 141-149
Whole-genome sequencing analysis of molecular epidemiology and silent transmissions causing meticillin-resistant Staphylococcus aureus bloodstream infections in a university hospital
- 8 June 2023
- Published by Elsevier in Journal of Hospital Infection
- Vol. 139, 141-149
Open AccessWhole-genome sequencing analysis of molecular epidemiology and silent transmissions causing meticillin-resistant Staphylococcus aureus bloodstream infections in a university hospital
- Open Access
- 20 August 2018
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 4 (1) , 22
Rapid, simple, and clinically applicable high-performance liquid chromatography method for clinical determination of plasma colistin concentrations
Since both the antibacterial effects and common adverse effects of colistin are concentration-dependent, determination of the most appropriate dosage regimen and administration method for colistin therapy is essential to ensure its efficacy and safety. We aimed to establish a rapid and simple high-performance liquid chromatography (HPLC)-based system for the clinical determination of colistin serum concentrations. Extraction using a solid-phase C18 cartridge, derivatisation with 9-fluorenylmethyl chloroformate, and elution with a short reversed-phase Cl8 column effectively separated colistin from an internal standard. The HPLC apparatus and conditions were as follows: analytical column, Hydrosphere C18; sample injection volume, 50 μL; column temperature, 40 °C; detector, Shimadzu RF-5300 fluorescence spectrophotometer (excitation wavelength, 260 nm; emission wavelength, 315 nm); mobile phase, acetonitrile/tetrahydrofuran/distilled water (50,14,20, v/v/v); flow-rate, 1.6 mL/min. The calibration curves obtained for colistin were linear in the concentration range of 0.10–8.0 μg/mL. The regression equation was y = 0.6496× − 0.0141 (r2 = 0.9999). The limit of detection was ~ 0.025 μg/mL, and the assay intra- and inter-day precisions were 0.87–3.74% and 1.97–6.17%, respectively. The analytical peaks of colistin A, colistin B, and the internal standard were resolved with adequate peak symmetries, and their retention times were approximately 8.2, 6.8, and 5.4 min, respectively. Furthermore, the assay was successfully applied to quantify the plasma colistin levels of a haemodialysis patient. The assay is a simple, rapid, accurate, selective, clinically applicable HPLC-based method for the quantification of colistin in human plasma.
- 20 August 2018
- Published by Springer Nature in Journal of Pharmaceutical Health Care and Sciences
- Vol. 4 (1) , 22
Open AccessRapid, simple, and clinically applicable high-performance liquid chromatography method for clinical determination of plasma colistin concentrations
Since both the antibacterial effects and common adverse effects of colistin are concentration-dependent, determination of the most appropriate dosage regimen and administration method for colistin therapy is essential to ensure its efficacy and safety. We aimed to establish a rapid and simple high-performance liquid chromatography (HPLC)-based system for the clinical determination of colistin serum concentrations. Extraction using a solid-phase C18 cartridge, derivatisation with 9-fluorenylmethyl chloroformate, and elution with a short reversed-phase Cl8 column effectively separated colistin from an internal standard. The HPLC apparatus and conditions were as follows: analytical column, Hydrosphere C18; sample injection volume, 50 μL; column temperature, 40 °C; detector, Shimadzu RF-5300 fluorescence spectrophotometer (excitation wavelength, 260 nm; emission wavelength, 315 nm); mobile phase, acetonitrile/tetrahydrofuran/distilled water (50,14,20, v/v/v); flow-rate, 1.6 mL/min. The calibration curves obtained for colistin were linear in the concentration range of 0.10–8.0 μg/mL. The regression equation was y = 0.6496× − 0.0141 (r2 = 0.9999). The limit of detection was ~ 0.025 μg/mL, and the assay intra- and inter-day precisions were 0.87–3.74% and 1.97–6.17%, respectively. The analytical peaks of colistin A, colistin B, and the internal standard were resolved with adequate peak symmetries, and their retention times were approximately 8.2, 6.8, and 5.4 min, respectively. Furthermore, the assay was successfully applied to quantify the plasma colistin levels of a haemodialysis patient. The assay is a simple, rapid, accurate, selective, clinically applicable HPLC-based method for the quantification of colistin in human plasma.