HXHua-Zi Xu

Hua-Zi Xu

*This is an algorithmically generated author record based on publicly available information.

Hua-Zi Xu has a total of 83 co-authors. Here are the top co-authors by number of shared publications:

  • Nai-Feng Tian

    Zhejiang Spine Research Center, Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    3 shared publications
  • Cong Xu

    Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, Wenzhou, China

    2 shared publications
  • Haixiao Liu

    Department of Orthopedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    2 shared publications
  • Libo Jiang

    Department of Orthopaedics The Second Affiliated Hospital of Wenzhou Medical University 109 Western Xueyuan Road Wenzhou China

    2 shared publications
  • Ming-Qiao Fang

    Zhejiang Spine Research Center, Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    2 shared publications
  • Naifeng Tian

    Department of Orthopaedics The Second Affiliated Hospital of Wenzhou Medical University 109 Western Xueyuan Road Wenzhou China

    2 shared publications

Latest Publications

  • Open Access

    Association of osteoarthritis and circulating adiponectin levels: a systematic review and meta-analysis

    by Qian Tang, Zhi-Chao Hu, Li-Yan Shen, Ping Shang, Hua-Zi Xu, Hai-Xiao Liu

    The objective of this study was to perform a meta-analysis to investigate the specific relationship between the expression level of circulating adiponectin and osteoarthritis (OA). Multiple databases were searched to estimate the high quality of studies relevant to adiponectin and OA. We extracted the data from the eligible studies and included them in the meta-analysis using a random effects model. Subgroup analysis and meta-regression were further performed to explore the potential sources of heterogeneity. Ten articles consisting of thirteen case-control studies that contained a combined total of 1255 subjects. Our results revealed that the OA patients displayed higher adiponectin levels than the healthy controls (SMD = 0.327, 95% CI: 0.11–0.55, P = 0.003). The ethnicity-stratified subgroup analysis indicated that the adiponectin was a sensitive biomarker in both Caucasians (P = 0.021) and Asians (P = 0.037). Moreover, the meta-regression analysis suggested that the sample size (P = 0.03) and nationality (p = 0.01) could account for a part of heterogeneity in our study. Taken together, the current study indicated that the adiponectin expression levels were higher in the OA patients than in the healthy controls and might be associated with OA prevalence.


  • Lithium chloride contributes to blood–spinal cord barrier integrity and functional recovery from spinal cord injury by stimulating autophagic flux

    by Minji Tong, Zili He, Xiaoxiao Lin, Yulong Zhou, Qingqing Wang, Zengming Zheng, Jian Chen, Huazi Xu, Naifeng Tian


  • Open Access

    Selective medial soft tissue release combined with tibial reduction osteotomy in total knee arthroplasty

    by Qian Tang, Hua-Chen Yu, Ping Shang, Shang-Kun Tang, Hua-Zi Xu, Hai-Xiao Liu, Yu Zhang

    To obtain the correct coronal alignment and balancing in flexion and extension, we established a selective medial release technique and investigated the effectiveness and safety of the technique during primary total knee arthroplasty (TKA). Four hundred sixty-six primary TKAs with varus deformity were prospectively evaluated between June 2013 and June 2015. A knee joint position similar to Patrick’s sign was used to release the medial structure. The medial release technique consisted of release of the capsule and the deep medial collateral ligament (dMCL) (step1), selective release of superficial medial collateral ligament (sMCL) or posterior oblique ligament (POL) (step 2), and selective tibial reduction osteotomy (step 3). Improvement of medial joint gap at each step and other clinical outcomes were evaluated. Among the 466 knees, symmetrical gaps could be achieved by the limited release of the capsule and the dMCcL in 276 (59%) knees. One hundred fifty-two (33%) required additional sMCL release with 2–5 cm from the joint line distally or POL release. Thirty-eight (8%) necessitated an additional tibial reduction osteotomy. Anterior-medial release and 4-mm medial osteotomy contributed to more improvement of medial gap in flexion than in extension (each p < 0.01). Posteromedial release and posteromedial osteotomy contributed to more improvement in extension than in flexion (each p < 0.01). No specific complication related to our technique was identified. The technique of the tibial reduction osteotomy combined with medial soft structure release using Patrick’s sign is effective, safe, and minimally invasive to obtain balanced mediolateral and extension-flexion gaps in primary TKA.


  • The Spinal Cord Line Can Predict Postoperative Recovery for Multilevel Cervical Spondylotic Myelopathy

    by Min-Ji Tong, Yuan-Bo Hu, Xiang-Yang Wang, Si-Pin Zhu, Nai-Feng Tian, Ming-Qiao Fang, Hua-Zi Xu, Guang-Heng Xiang


  • Open Access

    Dl-3-n-butylphthalide prevents the disruption of blood-spinal cord barrier via inhibiting endoplasmic reticulum stress following spinal cord injury

    by Binbin Zheng, Yulong Zhou, Hongyu Zhang, Guangyong Yang, Zhenghua Hong, Dandan Han, Qingqing Wang, Zili He, Yanlong Liu, Fenzan Wu, et al.

    After spinal cord injury (SCI), the destruction of blood-spinal cord barrier (BSCB) is shown to accelerate gathering of noxious blood-derived components in the nervous system, leading to secondary neurodegenerative damages. SCI activates endoplasmic reticulum stress (ER stress), which is considered to evoke secondary damages of neurons and glia. Recent evidence indicates that Dl-3-n-butylphthalide (NBP) has the neuroprotective effect in ischaemic brain injury, but whether it has protective effects on SCI or not is largely unclear. Here, we show that NBP prevented BSCB disruption after SCI via inhibition of ER stress. Following a moderate contusion injury of the T9 level of spinal cord, NBP was administered by oral gavage and further treated once a day. NBP significantly attenuated BSCB permeability and breakdown of adherens junction (AJ) and tight junction (TJ) proteins, then improved locomotion recovery following SCI. The protective role of NBP on BSCB disruption is associated with the restrain of ER stress caused by SCI. Furthermore, NBP considerably constrained the expression of ER stress-associated proteins and degradation of TJ and AJ in human brain microvascular endothelial cells (HBMECs) treated with TG. In conclusion, our results indicate that ER stress is associated with the disruption of BSCB integrity after injury, NBP attenuates BSCB disruption via inhibiting ER stress and improve functional recovery following SCI.


  • Open Access

    Calmodulin interacts with Rab3D and modulates osteoclastic bone resorption

    by Sipin Zhu, Shek Man Chim, Taksum Cheng, Estabelle Ang, Benjamin Ng, Baysie Lim, Kai Chen, Heng Qiu, Jennifer Tickner, Huazi Xu, et al.

    Calmodulin is a highly versatile protein that regulates intracellular calcium homeostasis and is involved in a variety of cellular functions including cardiac excitability, synaptic plasticity and signaling transduction. During osteoclastic bone resorption, calmodulin has been reported to concentrate at the ruffled border membrane of osteoclasts where it is thought to modulate bone resorption activity in response to calcium. Here we report an interaction between calmodulin and Rab3D, a small exocytic GTPase and established regulator osteoclastic bone resorption. Using yeast two-hybrid screening together with a series of protein-protein interaction studies, we show that calmodulin interacts with Rab3D in a calcium dependent manner. Consistently, expression of a calcium insensitive form of calmodulin (i.e. CaM1234) perturbs calmodulin-Rab3D interaction as monitored by bioluminescence resonance energy transfer (BRET) assays. In osteoclasts, calmodulin and Rab3D are constitutively co-expressed during RANKL-induced osteoclast differentiation, co-occupy plasma membrane fractions by differential gradient sedimentation assay and colocalise in the ruffled border as revealed by confocal microscopy. Further, functional blockade of calmodulin-Rab3D interaction by calmidazolium chloride coincides with an attenuation of osteoclastic bone resorption. Our data imply that calmodulin- Rab3D interaction is required for efficient bone resorption by osteoclasts in vitro.


  • An injectable nano-hydroxyapatite (n-HA)/glycol chitosan (G-CS)/hyaluronic acid (HyA) composite hydrogel for bone tissue engineering

    by Yixing Huang, Xiaolei Zhang, Aimin Wu, Huazi Xu

    The aim of the present study was to fabricate an injectable nano-hydroxyapatite (n-HA)/glycol chitosan (G-CS)/hyaluronic acid (HyA) composite hydrogel and investigate its potent application in bone tissue engineering. The resultant composite hydrogel was thoroughly characterized by Fourier transform infrared spectroscopy (FTIR) and X-ray diffractometry (XRD). The developed composite hydrogels exhibited a porous structure (pore size: 100–350 μm) associated with many n-HA particles and their aggregation inside the hydrogel, as indicated by scanning electron microscopy (SEM). With an increase in HyA concentration, the porosity and swelling ratio of the hydrogels decreased accordingly. The developed composite hydrogels were susceptive to the enzymatic hydrolysis, which exhibited a faster degradation rate in PBS solution containing 2.5 mg ml−1 lysozyme than that of in PBS (pH = 7.4). In vitro cytocompatibility was evaluated by using MC-3T3-E1 cells to confirm that the developed composite hydrogels were cytocompatible, non-toxic and cells were found to be attached and well spread out on the hydrogels after 7 days co-incubation. All these results suggest that the developed composite hydrogels has great potential for bone tissue engineering application.


  • Long-term effects of the Chêneau brace on coronal and sagittal alignment in adolescent idiopathic scoliosis

    by Ming-Qiao Fang, Chong Wang, Guang-Heng Xiang, Chao Lou, Nai-Feng Tian, Hua-Zi Xu

    OBJECT: The aim of the present study was to retrospectively evaluate progressive correction of coronal and sagittal alignment and pelvic parameters in patients treated with a Chêneau brace. METHODS: Thirty-two patients with adolescent idiopathic scoliosis (AIS) were assessed before initiation of bracing treatment and at the final follow-up. Each patient underwent radiological examinations, and coronal, sagittal, and pelvic parameters were measured. RESULTS: No statistically significant modification of the Cobb angle was noted. The pelvic incidence remained unchanged in 59% of the cases and increased in 28% of the cases. The sacral slope decreased in 34% of the cases but remained unchanged in 50%. Thoracic kyphosis and lumbar lordosis were significantly decreased, whereas the sagittal vertical axis was significantly increased from a mean of -44.0 to -30.2 mm (p = 0.02). The mean pelvic tilt increased significantly from 4.5° to 8.3° (p = 0.002). CONCLUSIONS: The Chêneau brace can be useful for preventing curvature progression in patients with AIS. However, the results of this study reveal high variability in the effect of brace treatment on sagittal and pelvic alignment. Treatment with the Chêneau brace may also influence sagittal global balance.


  • Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study

    by Ai-Min Wu, Wen-Fei Ni, Zhen-Xuan Shao, Xiang-Jie Kong, Nai-Feng Tian, Yi-Xing Huang, Zhong-Ke Lin, Hua-Zi Xu, Yong-Long Chi

    To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion. CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; θ the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope. According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully. Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.


  • Open Access

    The Effect of Postural Correction and Subsequent Balloon Inflation in Deformity Correction of Acute Osteoporotic Vertebral Fractures

    by Hai-Xiao Liu, Cong Xu, Ping Shang, Yue Shen, Hua-Zi Xu

    Liu HX, et al. J Korean Neurosurg Soc. 2014 Jun;55(6):337-342. http://dx.doi.org/10.3340/jkns.2014.55.6.337