Ying Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ying Song has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bo Xu
Department of Cardiology, National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Shenzhen, China
1 shared publication - Chen He
Department of Cardiology, The Guangxi Zhuang Autonomous Region Workers’ Hospital, Nanning, China
1 shared publication - Huanhuan Wang
Department of Cardiology, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China
1 shared publication - Jingjing Xu
Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
1 shared publication - Jinqing Yuan
National Clinical Research Center for Cardiovascular Diseases, State Key Laboratory of Cardiovascular Disease, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
1 shared publication - Lin Jiang
State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 14 August 2018
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 17 (1) , 1-12
Biodegradable polymer drug-eluting stents versus second-generation drug-eluting stents in patients with and without diabetes mellitus: a single-center study
To improve outcomes in patients with diabetes mellitus (DM) undergoing percutaneous coronary intervention remain an unmet clinical need. The study aimed to evaluate the efficacy and safety of G2-DESs and BP-DESs in patients with and without DM in a single center in China. A total of 7666 consecutive patients who exclusively had G2-DES or BP-DES implantation throughout 2013 in our center were studied. The primary efficacy endpoint was any target lesion revascularization (TLR), whereas the primary safety endpoint was a composite of death or myocardial infarction (MI) at 2-year follow-up. G2-DESs had a similar occurrence of death, non-fatal MI, TLR, stroke, and stent thrombosis compared with BP-DESs in patients with DM (all P > 0.05). The incidence of TVR and TLR was lower for G2-DESs than for BP-DESs in patients without DM (3.2% vs. 5.1%, P = 0.002; 2.2% vs. 4.5%, P < 0.001, respectively). Kaplan–Meier analysis also showed better TVR- and TLR-free survival rates for G2-DESs than for BP-DESs in patients without DM. Multivariate analysis showed that a BP-DES was an independent risk factor for TLR (hazard ratio 1.963, 95% confidence interval 1.390–2.772, P < 0.001) in patients without DM, which was not predictive of other components of major adverse cardiac events (P > 0.05). G2-DESs have better efficacy, represented by a reduced risk of TLR, and similar safety compared with BP-DESs in patients without DM. G2-DESs have similar efficacy and safety compared with BP-DESs in patients with DM at 2-year follow-up.
- 14 August 2018
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 17 (1) , 1-12
Open AccessBiodegradable polymer drug-eluting stents versus second-generation drug-eluting stents in patients with and without diabetes mellitus: a single-center study
To improve outcomes in patients with diabetes mellitus (DM) undergoing percutaneous coronary intervention remain an unmet clinical need. The study aimed to evaluate the efficacy and safety of G2-DESs and BP-DESs in patients with and without DM in a single center in China. A total of 7666 consecutive patients who exclusively had G2-DES or BP-DES implantation throughout 2013 in our center were studied. The primary efficacy endpoint was any target lesion revascularization (TLR), whereas the primary safety endpoint was a composite of death or myocardial infarction (MI) at 2-year follow-up. G2-DESs had a similar occurrence of death, non-fatal MI, TLR, stroke, and stent thrombosis compared with BP-DESs in patients with DM (all P > 0.05). The incidence of TVR and TLR was lower for G2-DESs than for BP-DESs in patients without DM (3.2% vs. 5.1%, P = 0.002; 2.2% vs. 4.5%, P < 0.001, respectively). Kaplan–Meier analysis also showed better TVR- and TLR-free survival rates for G2-DESs than for BP-DESs in patients without DM. Multivariate analysis showed that a BP-DES was an independent risk factor for TLR (hazard ratio 1.963, 95% confidence interval 1.390–2.772, P < 0.001) in patients without DM, which was not predictive of other components of major adverse cardiac events (P > 0.05). G2-DESs have better efficacy, represented by a reduced risk of TLR, and similar safety compared with BP-DESs in patients without DM. G2-DESs have similar efficacy and safety compared with BP-DESs in patients with DM at 2-year follow-up.