Hiroshi Hoshikawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroshi Hoshikawa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ryuhei Inamoto
Department of Otolaryngology, Kagawa University, Kagawa, Japan
2 shared publications - Takenori Miyashita
Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan
2 shared publications - Ai Matsubara
Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kita-gun, Japan
1 shared publication - Hirofumi Sakaguchi
Department of Otolaryngology-Head and Neck Surgery, Kyoto Prefectual University of Medicine, Kyoto, Japan
1 shared publication - Izumi Koizuka
Department of Otolaryngology, St. Marianna University School of Medicine, Kanagawa, Japan
1 shared publication - Nozomu Mori
Department of Otolaryngology, Kagawa University, School of Medicine, Kagawa, Japan
1 shared publication
Latest Publications
- Open Access
- 1 July 2021
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 17 (4) , 343-347
Temporal Adjusters Can Reduce Pain During the Video Head Impulse Test for Patients With Mongoloid Facial Features, Without Increasing the Slippage-Induced Artifacts
BACKGROUND: The aim of this study was to determine whether the extent and intensity of pain caused by wearing goggles during the video head impulse test (vHIT) could be reduced by adjusting the direction in which the band pulls the goggles, without increasing the number of artifacts recorded during vHIT. METHODS: vHIT tests were performed in 65 healthy adult subjects, and the Visual Analog Scale (VAS) and Numerical Rating Scale (NRS) were used to evaluate pain intensity. Temporal adjusters were used to adjust the direction in which the band pulls the goggles, without decreasing the tightness of the temple straps. Artifacts were compared by calculating the instantaneous gains at 40 ms, 60 ms, and 80 ms of head movement. RESULTS: Maximum VAS and NRS of pain were significantly reduced from 22.0 ± 2.3 to 13.0 ± 1.7 and from 3.0 ± 0.2 to 2.0 ± 0.2 (both P < .0001). The VAS score without adjusters was significantly correlated with the improvement of the VAS score with temporal adjusters (P < .0001, r = 0.61). The higher the VAS score without adjusters, the greater the improvement in the VAS score with temporal adjusters. The instantaneous gains were close to 1.0 under both conditions. CONCLUSION: The pain induced by the goggle was significantly mitigated with temporal adjusters in the bilateral temple strap. Using temporal adjusters is a useful and easy solution to reduce discomfort during vHIT, while maintaining the tightness of the strap to decrease the slippageinduced artifacts. Cite this article as: Takahashi S, Miyashita T, Inamoto R, et al. Temporal adjusters can reduce pain during the video head impulse test for patients with mongoloid facial features, without increasing the slippage-induced artifacts. J Int Adv Otol. 2021; 17(4): 343-347.
- 1 July 2021
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 17 (4) , 343-347
Open AccessTemporal Adjusters Can Reduce Pain During the Video Head Impulse Test for Patients With Mongoloid Facial Features, Without Increasing the Slippage-Induced Artifacts
BACKGROUND: The aim of this study was to determine whether the extent and intensity of pain caused by wearing goggles during the video head impulse test (vHIT) could be reduced by adjusting the direction in which the band pulls the goggles, without increasing the number of artifacts recorded during vHIT. METHODS: vHIT tests were performed in 65 healthy adult subjects, and the Visual Analog Scale (VAS) and Numerical Rating Scale (NRS) were used to evaluate pain intensity. Temporal adjusters were used to adjust the direction in which the band pulls the goggles, without decreasing the tightness of the temple straps. Artifacts were compared by calculating the instantaneous gains at 40 ms, 60 ms, and 80 ms of head movement. RESULTS: Maximum VAS and NRS of pain were significantly reduced from 22.0 ± 2.3 to 13.0 ± 1.7 and from 3.0 ± 0.2 to 2.0 ± 0.2 (both P < .0001). The VAS score without adjusters was significantly correlated with the improvement of the VAS score with temporal adjusters (P < .0001, r = 0.61). The higher the VAS score without adjusters, the greater the improvement in the VAS score with temporal adjusters. The instantaneous gains were close to 1.0 under both conditions. CONCLUSION: The pain induced by the goggle was significantly mitigated with temporal adjusters in the bilateral temple strap. Using temporal adjusters is a useful and easy solution to reduce discomfort during vHIT, while maintaining the tightness of the strap to decrease the slippageinduced artifacts. Cite this article as: Takahashi S, Miyashita T, Inamoto R, et al. Temporal adjusters can reduce pain during the video head impulse test for patients with mongoloid facial features, without increasing the slippage-induced artifacts. J Int Adv Otol. 2021; 17(4): 343-347.
- Open Access
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (2) , 312-316
Tricellulin Expression and its Deletion Effects in the Endolymphatic Sac
OBJECTIVES: Tricellulin is a tight junction (TJ)-forming protein that participates in the sealing function of tricellular TJs. Tricellulin-knockout (Tric−/−) mice show progressive hearing loss with degeneration of hair cells in the cochlea without physiological or physical disorders. In the present study, we investigated the tricellulin expression and its deletion effects in the endolymphatic sac (ES) using Tric−/− mice. MATERIALS and METHODS: The ES epithelia from wild-type (WT) mice were laser-microdissected, and RT-PCR was performed. The ES sections from Tric−/− and WT mice were immunostained with an anti-tricellulin antibody. Hematoxylin and eosin staining was performed for morphological examination. The inner ear of Tric−/− mice was perfused with biotinylation reagents, and the ES sections were observed for tracer permeability assay after applying streptavidin–Alexa Fluor 488 conjugate. RESULTS: The tricellulin expression was confirmed by RT-PCR and by immunohistochemistry in the WT ES. The ES in Tric−/− mice showed normal morphology and revealed no biotin leakage from the lumen. CONCLUSION: The ES in Tric−/− mice showed no changes in morphology or disruption in macromolecular barrier function. The effects of solute leakages in the ES of Tric−/− mice may be very limited and compensatable, or that the ES epithelia may have other sealing system covering the lack of tricellulin. Cite this article as: Matsubara A, Miyashita T, Inamoto R, Sakaguchi H, Kamitani T, Mori N, et al. Tricellulin Expression and its Deletion Effects in the Endolymphatic Sac. J Int Adv Otol 2018; 14(2): 312-6.
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (2) , 312-316
Open AccessTricellulin Expression and its Deletion Effects in the Endolymphatic Sac
OBJECTIVES: Tricellulin is a tight junction (TJ)-forming protein that participates in the sealing function of tricellular TJs. Tricellulin-knockout (Tric−/−) mice show progressive hearing loss with degeneration of hair cells in the cochlea without physiological or physical disorders. In the present study, we investigated the tricellulin expression and its deletion effects in the endolymphatic sac (ES) using Tric−/− mice. MATERIALS and METHODS: The ES epithelia from wild-type (WT) mice were laser-microdissected, and RT-PCR was performed. The ES sections from Tric−/− and WT mice were immunostained with an anti-tricellulin antibody. Hematoxylin and eosin staining was performed for morphological examination. The inner ear of Tric−/− mice was perfused with biotinylation reagents, and the ES sections were observed for tracer permeability assay after applying streptavidin–Alexa Fluor 488 conjugate. RESULTS: The tricellulin expression was confirmed by RT-PCR and by immunohistochemistry in the WT ES. The ES in Tric−/− mice showed normal morphology and revealed no biotin leakage from the lumen. CONCLUSION: The ES in Tric−/− mice showed no changes in morphology or disruption in macromolecular barrier function. The effects of solute leakages in the ES of Tric−/− mice may be very limited and compensatable, or that the ES epithelia may have other sealing system covering the lack of tricellulin. Cite this article as: Matsubara A, Miyashita T, Inamoto R, Sakaguchi H, Kamitani T, Mori N, et al. Tricellulin Expression and its Deletion Effects in the Endolymphatic Sac. J Int Adv Otol 2018; 14(2): 312-6.