Alicia Huarte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alicia Huarte has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Manrique
Department of Otorhinolaryngology, Clinica Universidad de Navarra, 31008 Pamplona, Spain
23 shared publications - Francisco Javier Cervera-Paz
Department of Otorhinolaryngology, University of Navarra Hospital and Medical School, Pamplona, Spain
7 shared publications M Molina
5 shared publicationsJ M Espinosa
4 shared publicationsMaite Molina
Department of Otorhinolaryngology, Head and Neck Surgery Division, University of Navarra Hospital and Medical School, Pamplona, Navarra, Spain
4 shared publications- Raquel Manrique-Huarte
Department of Otorhinolaryngology, Clinica Universidad de Navarra, 31008 Pamplona, Spain
4 shared publications
Latest Publications
- Open Access
Early Detection of Hearing Loss among the Elderly
Background: Age-related hearing loss (ARHL) is a complex communication disorder that affects the cochlea and central auditory pathway. The goal of this study is to characterize this type of hearing loss and to identify non-invasive, inexpensive, and quick tests to detect ARHL among elderly adults, seeking to preserve quality of life and reduce the burden on healthcare systems. Methods: An observational, prospective study is conducted with >55-year-old subjects divided into the following groups: normal range (Group A), detected but not treated (Group B), and detected and treated (Group C). During follow-up, Speech Spatial Qualities (SSQ12), and Hearing Handicap Inventory in the Elderly Screening test (HHIE-S) questionnaires were assessed, along with hearing levels (hearing thresholds at 4 kHz were studied in more depth), and a series of tests and questionnaires to assess balance, cognitive level, level of dependence, and depression. Results: A total of 710 patients were included in this study. The duration of hearing loss (11.8 yr. in Group B and 21.0 yr. in Group C) and average time-to-treatment for Group C (14.1 yr.) are both protracted. Both of the used questionnaires show statistically significant differences among the groups, revealing greater handicaps for Group C. Audiometry performed at 4 kHz shows how hearing loss progresses with age, finding differences between men and women. There is a correlation between time-to-treatment in Group C and the cognitive test DSST (−0.26; p = 0.003). Conclusions: HHIE-S, SSQ12, and 4 kHz audiometry are sensitive and feasible tests to implement in screening programs.
Open AccessEarly Detection of Hearing Loss among the Elderly
Background: Age-related hearing loss (ARHL) is a complex communication disorder that affects the cochlea and central auditory pathway. The goal of this study is to characterize this type of hearing loss and to identify non-invasive, inexpensive, and quick tests to detect ARHL among elderly adults, seeking to preserve quality of life and reduce the burden on healthcare systems. Methods: An observational, prospective study is conducted with >55-year-old subjects divided into the following groups: normal range (Group A), detected but not treated (Group B), and detected and treated (Group C). During follow-up, Speech Spatial Qualities (SSQ12), and Hearing Handicap Inventory in the Elderly Screening test (HHIE-S) questionnaires were assessed, along with hearing levels (hearing thresholds at 4 kHz were studied in more depth), and a series of tests and questionnaires to assess balance, cognitive level, level of dependence, and depression. Results: A total of 710 patients were included in this study. The duration of hearing loss (11.8 yr. in Group B and 21.0 yr. in Group C) and average time-to-treatment for Group C (14.1 yr.) are both protracted. Both of the used questionnaires show statistically significant differences among the groups, revealing greater handicaps for Group C. Audiometry performed at 4 kHz shows how hearing loss progresses with age, finding differences between men and women. There is a correlation between time-to-treatment in Group C and the cognitive test DSST (−0.26; p = 0.003). Conclusions: HHIE-S, SSQ12, and 4 kHz audiometry are sensitive and feasible tests to implement in screening programs.
- 21 October 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (1) , 69-76
Comparative study of two different perimodiolar and a straight cochlear implant electrode array: surgical and audiological outcomes
To compare the surgical and audiological outcomes with two perimodiolar electrode arrays (Nucleus 512-Contour Advance® y Nucleus 532-Slim Perimodiolar®) and a straight electrode array (Nucleus 422/522).
- 21 October 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (1) , 69-76
Comparative study of two different perimodiolar and a straight cochlear implant electrode array: surgical and audiological outcomes
To compare the surgical and audiological outcomes with two perimodiolar electrode arrays (Nucleus 512-Contour Advance® y Nucleus 532-Slim Perimodiolar®) and a straight electrode array (Nucleus 422/522).
- Open Access
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 12 (1) , 16-22
Bimodal Stimulation with Cochlear Implant and Hearing Aid in Cases of Highly Asymmetrical Hearing Loss
OBJECTIVE: Bimodal stimulation is a possible treatment for asymmetrical hearing loss, wherein 1 ear is stimulated with a cochlear implant and the other is stimulated with a hearing aid. This emerging indication has gained significance over the last few years. However, little research has been conducted regarding the performance in different types of asymmetric Hearing loss. This study seeks to prove the bilateral–binaural advantage in a group of patients treated with bimodal stimulation (cochlear implant and hearing aid), with different degrees of hearing loss in their best ear. MATERIALS and METHODS: In total, 31 patients were recruited for the study. They were divided into 3 groups on the basis of the ear with the hearing aid: Group A, pure tone average (PTA) between 41 and 70 dB HL; Group B, PTA between 71 and 80 dB HL; and Group C, PTA between 81 and 90 dB HL. The performance in PTA and disyllabic word recognition were analyzed separately in each ear and then bimodally. The minimum follow-up period was 2 years. RESULTS: There were statistically significant differences between bimodal and monaural conditions both in PTA and in disyllabic word recognition. The better the residual hearing in the ear with the hearing aid, the greater were the benefits obtained with bilateralism–binaurality. CONCLUSION: Bimodal stimulation provides better results than any monaural hearing mode, regardless of whether it involves the use of a hearing aid alone or a cochlear implant alone.
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 12 (1) , 16-22
Open AccessBimodal Stimulation with Cochlear Implant and Hearing Aid in Cases of Highly Asymmetrical Hearing Loss
OBJECTIVE: Bimodal stimulation is a possible treatment for asymmetrical hearing loss, wherein 1 ear is stimulated with a cochlear implant and the other is stimulated with a hearing aid. This emerging indication has gained significance over the last few years. However, little research has been conducted regarding the performance in different types of asymmetric Hearing loss. This study seeks to prove the bilateral–binaural advantage in a group of patients treated with bimodal stimulation (cochlear implant and hearing aid), with different degrees of hearing loss in their best ear. MATERIALS and METHODS: In total, 31 patients were recruited for the study. They were divided into 3 groups on the basis of the ear with the hearing aid: Group A, pure tone average (PTA) between 41 and 70 dB HL; Group B, PTA between 71 and 80 dB HL; and Group C, PTA between 81 and 90 dB HL. The performance in PTA and disyllabic word recognition were analyzed separately in each ear and then bimodally. The minimum follow-up period was 2 years. RESULTS: There were statistically significant differences between bimodal and monaural conditions both in PTA and in disyllabic word recognition. The better the residual hearing in the ear with the hearing aid, the greater were the benefits obtained with bilateralism–binaurality. CONCLUSION: Bimodal stimulation provides better results than any monaural hearing mode, regardless of whether it involves the use of a hearing aid alone or a cochlear implant alone.
- Open Access
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (1) , 18-21
Vestibulo-Cochlear Function After Cochlear Implantation in Patients With Meniere’s Disease
OBJECTIVES: To measure the auditory (pure tone audiometry and word recognition scores) and vestibular (video head impulse test and vestibular myogenic potentials) outcomes in patients diagnosed with Meniere’s disease (MD) who underwent cochlear implantation. MATERIAL AND METHODS: This prospective study included 23 cochlear implant users with MD and 29 patients diagnosed with far-advanced otosclerosis (the control group). RESULTS: The preoperative mean pure tone average thresholds were 99 and 122.5 dB for the Meniere’s and control groups, respectively. Word recognition scores after cochlear implant yielded a median of 80% and 72% for the Meniere’s and control groups, respectively. Semicircular canal gain was not observed to vary post implantation (mean variation for lateral, posterior, and anterior plane was 0, 0.03, and 0, respectively). The mean ocular and cervical myogenic potentials asymmetry varied as 9.65% and 18.39%, respectively. CONCLUSIONS: The auditory performance improved in patients with MD similar to the general cochlear implant population. No major dysfunction of otolithic or semicircular canal function was demonstrated after the implantation surgery. Cite this article as: Manrique-Huarte R, Calavia D, Alvarez-Gomez L, Huarte A, Perez-Fernández N, Manrique M. Vestibulo-Cochlear Function After Cochlear Implantation in Patients With Meniere’s Disease. J Int Adv Otol 2018; 14(1): 18-22.
- 3 September 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 14 (1) , 18-21
Open AccessVestibulo-Cochlear Function After Cochlear Implantation in Patients With Meniere’s Disease
OBJECTIVES: To measure the auditory (pure tone audiometry and word recognition scores) and vestibular (video head impulse test and vestibular myogenic potentials) outcomes in patients diagnosed with Meniere’s disease (MD) who underwent cochlear implantation. MATERIAL AND METHODS: This prospective study included 23 cochlear implant users with MD and 29 patients diagnosed with far-advanced otosclerosis (the control group). RESULTS: The preoperative mean pure tone average thresholds were 99 and 122.5 dB for the Meniere’s and control groups, respectively. Word recognition scores after cochlear implant yielded a median of 80% and 72% for the Meniere’s and control groups, respectively. Semicircular canal gain was not observed to vary post implantation (mean variation for lateral, posterior, and anterior plane was 0, 0.03, and 0, respectively). The mean ocular and cervical myogenic potentials asymmetry varied as 9.65% and 18.39%, respectively. CONCLUSIONS: The auditory performance improved in patients with MD similar to the general cochlear implant population. No major dysfunction of otolithic or semicircular canal function was demonstrated after the implantation surgery. Cite this article as: Manrique-Huarte R, Calavia D, Alvarez-Gomez L, Huarte A, Perez-Fernández N, Manrique M. Vestibulo-Cochlear Function After Cochlear Implantation in Patients With Meniere’s Disease. J Int Adv Otol 2018; 14(1): 18-22.
- 1 March 2017
- Published by Elsevier in Acta Otorrinolaringológica Española
- Vol. 68 (2) , 92-97
Actividad laboral en pacientes tratados con implantes cocleares
- 1 March 2017
- Published by Elsevier in Acta Otorrinolaringológica Española
- Vol. 68 (2) , 92-97
Actividad laboral en pacientes tratados con implantes cocleares
- 27 March 2015
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (3) , 621-629
Surgical findings and auditory performance after cochlear implant revision surgery
The objective of this study was to review cochlear reimplantation outcomes in the tertiary hospital and analyze whether facts such as type of failure, surgical findings, or etiology of deafness have an influence. A retrospective study including 38 patients who underwent cochlear implant revision surgery in a tertiary center is performed. Auditory outcomes (pure tone audiometry, % disyllabic words) along with etiology of deafness, type of complication, issues with insertion, and cochlear findings are included. Complication rate is 2.7 %. Technical failure rate is 57.9 % (50 % hard failure and 50 % soft failure), and medical failure (device infection or extrusion, migration, wound, or flap complication) is seen in 42.1 % of the cases. Management of cochlear implant complications and revision surgery is increasing due to a growing number of implantees. Cases that require explantation and reimplantation of the cochlear implant are safe procedures, where the depth of insertion and speech perception results are equal or higher in most cases. Nevertheless, there must be an increasing effort on using minimally traumatic electrode arrays and surgical techniques to improve currently obtained results.
- 27 March 2015
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (3) , 621-629
Surgical findings and auditory performance after cochlear implant revision surgery
The objective of this study was to review cochlear reimplantation outcomes in the tertiary hospital and analyze whether facts such as type of failure, surgical findings, or etiology of deafness have an influence. A retrospective study including 38 patients who underwent cochlear implant revision surgery in a tertiary center is performed. Auditory outcomes (pure tone audiometry, % disyllabic words) along with etiology of deafness, type of complication, issues with insertion, and cochlear findings are included. Complication rate is 2.7 %. Technical failure rate is 57.9 % (50 % hard failure and 50 % soft failure), and medical failure (device infection or extrusion, migration, wound, or flap complication) is seen in 42.1 % of the cases. Management of cochlear implant complications and revision surgery is increasing due to a growing number of implantees. Cases that require explantation and reimplantation of the cochlear implant are safe procedures, where the depth of insertion and speech perception results are equal or higher in most cases. Nevertheless, there must be an increasing effort on using minimally traumatic electrode arrays and surgical techniques to improve currently obtained results.
- Open Access
- 1 January 2014
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 19 (Suppl. 1) , 36-39
Quality of Life Outcomes for Cochlear Implantation in the Elderly
Objectives: To determine whether individuals older than 60 years of age suffering from profound, bilateral, sensorineural hearing loss and unable to use hearing aids can benefit from a cochlear implant in order to improve hearing performance. Additionally, to evaluate how they manage the external components of their implanted system. Materials and Methods: The records of 68 cochlear implant users over 60 years of age were reviewed. They had undergone tonal and speech audiometry evaluations of hearing before and after implantation. A subset of 27 elderly patients were asked to respond to a specially designed questionnaire regarding the use of the external components of the implanted system. Results: Patients over 60 years of age benefit from cochlear implants. The earlier the implantation, the better the results tend to be. Certain limitations when using the external components of the implanted system were evident among the elderly. Conclusions: People >60 years of age suffering from profound, bilateral, sensorineural hearing loss show improved hearing performance following cochlear implantation. Using the implanted system includes some limitations that should be studied and overcome.
- 1 January 2014
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 19 (Suppl. 1) , 36-39
Open AccessQuality of Life Outcomes for Cochlear Implantation in the Elderly
Objectives: To determine whether individuals older than 60 years of age suffering from profound, bilateral, sensorineural hearing loss and unable to use hearing aids can benefit from a cochlear implant in order to improve hearing performance. Additionally, to evaluate how they manage the external components of their implanted system. Materials and Methods: The records of 68 cochlear implant users over 60 years of age were reviewed. They had undergone tonal and speech audiometry evaluations of hearing before and after implantation. A subset of 27 elderly patients were asked to respond to a specially designed questionnaire regarding the use of the external components of the implanted system. Results: Patients over 60 years of age benefit from cochlear implants. The earlier the implantation, the better the results tend to be. Certain limitations when using the external components of the implanted system were evident among the elderly. Conclusions: People >60 years of age suffering from profound, bilateral, sensorineural hearing loss show improved hearing performance following cochlear implantation. Using the implanted system includes some limitations that should be studied and overcome.
- 5 June 2012
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 132 (10) , 1084-1094
Contralateral hearing aid use in cochlear implanted patients: Multicenter study of bimodal benefit
Conclusion: The use of a hearing aid (HA) in combination with a cochlear implant (CI) significantly improved performance for speech perception in quiet, in noise, and for localization compared with monaural conditions. No significant differences in functional performance were observed following optimization of HA fitting. Objectives: To evaluate the binaural benefits derived from using a contralateral HA in conjunction with a CI in subjects with significant functional hearing in the nonimplanted ear and the effects of HA fitting optimization. Methods: Fifteen adult CI users, intra-subject controls, were enrolled in a prospective repeated-measure multicenter study. Evaluation of performance for speech understanding, localization, and subjective impressions was conducted before and following HA fitting optimization for CI alone, HA alone, and CI + HA. Results: For speech testing in quiet, bimodal scores were significantly better than for HA alone and CI alone conditions (p < 0.01). For speech and noise (S0N0) at 0° azimuth the scores were significantly better in the bimodal condition than for CI alone (p = 0.01), indicating binaural summation. When noise was presented to the HA side (S0NHA) bimodal scores were significantly better than for CI alone (p < 0.01 and p < 0.05, respectively), suggesting a significant binaural squelch effect. Sound localization ability was significantly improved in the bimodal condition compared with the CI alone condition (p = 0.002).
- 5 June 2012
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 132 (10) , 1084-1094
Contralateral hearing aid use in cochlear implanted patients: Multicenter study of bimodal benefit
Conclusion: The use of a hearing aid (HA) in combination with a cochlear implant (CI) significantly improved performance for speech perception in quiet, in noise, and for localization compared with monaural conditions. No significant differences in functional performance were observed following optimization of HA fitting. Objectives: To evaluate the binaural benefits derived from using a contralateral HA in conjunction with a CI in subjects with significant functional hearing in the nonimplanted ear and the effects of HA fitting optimization. Methods: Fifteen adult CI users, intra-subject controls, were enrolled in a prospective repeated-measure multicenter study. Evaluation of performance for speech understanding, localization, and subjective impressions was conducted before and following HA fitting optimization for CI alone, HA alone, and CI + HA. Results: For speech testing in quiet, bimodal scores were significantly better than for HA alone and CI alone conditions (p < 0.01). For speech and noise (S0N0) at 0° azimuth the scores were significantly better in the bimodal condition than for CI alone (p = 0.01), indicating binaural summation. When noise was presented to the HA side (S0NHA) bimodal scores were significantly better than for CI alone (p < 0.01 and p < 0.05, respectively), suggesting a significant binaural squelch effect. Sound localization ability was significantly improved in the bimodal condition compared with the CI alone condition (p = 0.002).
- 1 February 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (2) , 187-191
Auditory Brainstem Implantation in Children and Non-Neurofibromatosis Type 2 Patients
- 1 February 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (2) , 187-191
Auditory Brainstem Implantation in Children and Non-Neurofibromatosis Type 2 Patients
- 1 January 2008
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 47 (6) , 369-370
The Castilian Spanish Hearing in Noise Test
- 1 January 2008
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 47 (6) , 369-370
The Castilian Spanish Hearing in Noise Test