Song Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Song Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fengxian Li
Department of Anesthesiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
2 shared publications - Minqiang Liu
Department of Anesthesiology, Shenzhen Third People’s Hospital, No. 29 Bulan Road, Longgang District, Shenzhen, 518112, Guangdong, China
2 shared publications - Renliang He
Department of Anesthesiology, Shenzhen Third People’s Hospital, No. 29 Bulan Road, Longgang District, Shenzhen, 518112, Guangdong, China
2 shared publications - Zhichao Li
Department of Anesthesiology, Shenzhen Third People’s Hospital, No. 29 Bulan Road, Longgang District, Shenzhen, 518112, Guangdong, China
2 shared publications - Danling Yang
Department of Endoscopy, Shenzhen Third People’s Hospital, No. 29 Bulan Road, Longgang District, Shenzhen, 518112, Guangdong, China
1 shared publication - Hongyan Wu
Department of Endoscopy, Shenzhen Third People’s Hospital, No. 29 Bulan Road, Longgang District, Shenzhen, 518112, Guangdong, China
1 shared publication
Latest Publications
- Open Access
- 15 March 2019
- Published by Springer Nature in Trials
- Vol. 20 (1) , 170
Application via mechanical dropper alleviates sufentanil-induced cough: a prospective, randomized, single-blinded trial
It was reported that prolonging the injection time or diluting administration can reduce the incidence of opioid-induced cough. However, the incidence of sufentanil-induced cough (SIC) via a standardized infusion rate is unclear. A mechanical dropper is an infusion filtering device commonly used for intravenous degassing; it can also be used to administer special drugs due to its temporary storage and dilution effect. This study assesses the effectiveness of administration via mechanical dropper on SIC. Two hundred patients undergoing general anesthesia were enrolled. Patients received sufentanil at a strength of 0.3 μg·kg− 1 either via T-connector (group C) or by mechanical dropper (group M) at 1 ml·s− 1. Cough severity was graded as none (0), mild (1–2), moderate (3–5), or severe (> 5), and the incidence of SIC was evaluated for 5 min after the start of sufentanil injection. Other adverse reactions such as hypotension, hypertension, bradycardia, tachycardia, hypoxemia, vomiting, and aspiration during the induction period of general anesthesia were also observed. The primary outcome was the incidence of SIC. The secondary outcomes were the severity of SIC and other adverse reactions. The incidence of SIC in group M was significantly lower than that in group C (2% versus 21%, P = 0.000), and the prevalence of moderately severe coughing was also statistically different (none in group M versus 11% in group C, P = 0.001). However, there were no statistical differences in the incidence of other adverse reactions between two groups (P > 0.05). Sufentanil application via mechanical dropper can significantly alleviate the occurrence of SIC during the induction phase of total intravenous general anesthesia. This method is simple, safe, and reliable, and has wide prospective application for clinical use. Chinese Clinical Trial Register, ChiCTR-IOR-17011561 . Registered on 3 June 2017.
- 15 March 2019
- Published by Springer Nature in Trials
- Vol. 20 (1) , 170
Open AccessApplication via mechanical dropper alleviates sufentanil-induced cough: a prospective, randomized, single-blinded trial
It was reported that prolonging the injection time or diluting administration can reduce the incidence of opioid-induced cough. However, the incidence of sufentanil-induced cough (SIC) via a standardized infusion rate is unclear. A mechanical dropper is an infusion filtering device commonly used for intravenous degassing; it can also be used to administer special drugs due to its temporary storage and dilution effect. This study assesses the effectiveness of administration via mechanical dropper on SIC. Two hundred patients undergoing general anesthesia were enrolled. Patients received sufentanil at a strength of 0.3 μg·kg− 1 either via T-connector (group C) or by mechanical dropper (group M) at 1 ml·s− 1. Cough severity was graded as none (0), mild (1–2), moderate (3–5), or severe (> 5), and the incidence of SIC was evaluated for 5 min after the start of sufentanil injection. Other adverse reactions such as hypotension, hypertension, bradycardia, tachycardia, hypoxemia, vomiting, and aspiration during the induction period of general anesthesia were also observed. The primary outcome was the incidence of SIC. The secondary outcomes were the severity of SIC and other adverse reactions. The incidence of SIC in group M was significantly lower than that in group C (2% versus 21%, P = 0.000), and the prevalence of moderately severe coughing was also statistically different (none in group M versus 11% in group C, P = 0.001). However, there were no statistical differences in the incidence of other adverse reactions between two groups (P > 0.05). Sufentanil application via mechanical dropper can significantly alleviate the occurrence of SIC during the induction phase of total intravenous general anesthesia. This method is simple, safe, and reliable, and has wide prospective application for clinical use. Chinese Clinical Trial Register, ChiCTR-IOR-17011561 . Registered on 3 June 2017.
- Open Access
- 18 July 2018
- Published by Springer Nature in Trials
- Vol. 19 (1) , 1-12
Effects of small-dose remifentanil combined with index of consciousness monitoring on gastroscopic polypectomy: a prospective, randomized, single-blinded trial
With the development of painless diagnosis and treatment, remifentanil, a synthetic opioid agonist, is increasingly used in gastroscopy for its rapid, short-term, and potent analgesic effect. However, the dosage of remifentanil used in endoscopy is unclear. Index of consciousness (IOC) is a new anesthesia depth-monitoring indicator that can be divided into index of consciousness 1 (IOC1) and index of consciousness 2 (IOC2); IOC1 is used for estimating a patient’s sedation state, whereas IOC2 reflects analgesic depth. We hypothesized that combining with IOC1 and IOC2 monitoring may be helpful to identify an optimal remifentanil dosage in gastroscopic polypectomy. One hundred twenty patients scheduled for gastroscopic polypectomy were enrolled and were randomly assigned to remifentanil 2 ng/mL (group R2), 4 ng/mL (group R4), or 6 ng/mL (group R6), and 40 cases were in each group. During the anesthesia period, remifentanil was kept at the initial given concentration but propofol was adjusted according to IOC1. The primary outcomes were the dosage of propofol and remifentanil. The secondary outcomes were the variety of IOC1 and IOC2, patients’ awakening time, and peri-operative adverse reactions such as hypotension, hypertension, bradycardia, tachycardia, body movements, hypoxemia, therapy interruption, nausea, vomiting, aspiration, and intra-operative awareness. With the increasing dosage of remifentanil, the propofol dosage and patients’ awakening time decreased significantly, the morbidity of hypertension and body movements also declined, but the incidence of hypotension, bradycardia, and hypoxemia rose. In group R2, the value of IOC2 remained above 50 during the treatment. However, IOC2 dropped to below 30 at the beginning of the gastroscopy in group R6, and there was statistical difference in hypoxemia between groups R2 and R6 (P <0.05). With the help of IOC monitoring, we found that a target concentration of remifentanil 4 ng/mL is comparatively ideal in patients under gastroscopic polypectomy. Chinese Clinical Trial Register: ChiCTR-OOD-16009489 , on October 19, 2016.
- 18 July 2018
- Published by Springer Nature in Trials
- Vol. 19 (1) , 1-12
Open AccessEffects of small-dose remifentanil combined with index of consciousness monitoring on gastroscopic polypectomy: a prospective, randomized, single-blinded trial
With the development of painless diagnosis and treatment, remifentanil, a synthetic opioid agonist, is increasingly used in gastroscopy for its rapid, short-term, and potent analgesic effect. However, the dosage of remifentanil used in endoscopy is unclear. Index of consciousness (IOC) is a new anesthesia depth-monitoring indicator that can be divided into index of consciousness 1 (IOC1) and index of consciousness 2 (IOC2); IOC1 is used for estimating a patient’s sedation state, whereas IOC2 reflects analgesic depth. We hypothesized that combining with IOC1 and IOC2 monitoring may be helpful to identify an optimal remifentanil dosage in gastroscopic polypectomy. One hundred twenty patients scheduled for gastroscopic polypectomy were enrolled and were randomly assigned to remifentanil 2 ng/mL (group R2), 4 ng/mL (group R4), or 6 ng/mL (group R6), and 40 cases were in each group. During the anesthesia period, remifentanil was kept at the initial given concentration but propofol was adjusted according to IOC1. The primary outcomes were the dosage of propofol and remifentanil. The secondary outcomes were the variety of IOC1 and IOC2, patients’ awakening time, and peri-operative adverse reactions such as hypotension, hypertension, bradycardia, tachycardia, body movements, hypoxemia, therapy interruption, nausea, vomiting, aspiration, and intra-operative awareness. With the increasing dosage of remifentanil, the propofol dosage and patients’ awakening time decreased significantly, the morbidity of hypertension and body movements also declined, but the incidence of hypotension, bradycardia, and hypoxemia rose. In group R2, the value of IOC2 remained above 50 during the treatment. However, IOC2 dropped to below 30 at the beginning of the gastroscopy in group R6, and there was statistical difference in hypoxemia between groups R2 and R6 (P <0.05). With the help of IOC monitoring, we found that a target concentration of remifentanil 4 ng/mL is comparatively ideal in patients under gastroscopic polypectomy. Chinese Clinical Trial Register: ChiCTR-OOD-16009489 , on October 19, 2016.