Young Min Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Young Min Lee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Du Hyun Ro
Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea
2 shared publications - Myung Chul Lee
Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea
2 shared publications - Seong Hwan Kim
Department of Orthopedic Surgery Chung‐Ang University Hospital Seoul Republic of Korea
2 shared publications - Joon Kyu Lee
Department of Orthopaedic Surgery, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, South Korea
1 shared publication - Joon Kyu Lee
Department of Orthopaedic Surgery, Konkuk University Medical Center, Seoul 05030, Republic of Korea
1 shared publication - Joong Il Kim
Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- 1 July 2020
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 54 (4) , 444-453
Factors that Predicts the Size of Autologous Hamstring Tendon Graft for Double-Bundle ACL Reconstruction
Background To evaluate the effectiveness of demographic data and radiographic measurements for predicting the diameter and length of autologous semitendinosus (ST) and gracilis (GR) graft. Materials and Methods Fifty-four cases were included to measure the size of 3 or 4 strands of ST and GR tendons retrospectively. The hamstring length on radiograph was defined as the length from the lowest point of ischial tuberosity to intercondylar notch of the femur. The linear and logistic regression analysis was used to assess the roles of the predictor variables, as demographic and radiologic data, in the outcome variables, as diameter of tendon grafts. The cross-validation with hold-out samples and concordance correlation coefficient (CCC) were also calculated. Results The hamstring and leg length measurement and gender were associated with the diameter of 4-stranded ST tendon graft. The hamstring length measurement, age and BMI were the factors associated with the diameter of 3-stranded ST tendon graft. The hamstring length measurement was found as a common factor for predicting diameters of hamstring tendon with reliable predictability. Moreover, the equation of multivariate regression analysis for the diameter of 4-stranded ST tendon graft showed the most validated power of prediction. All of the cross-validated R-2 values were calculated as similar results of multivariate model, but CCC between the measured diameter and estimated value on the predictive equation showed moderate agreement only (CCC = 0.694). Conclusions Combining radiographic length measurements with demographic data showed reliable prediction in identifying the risk of inappropriate graft diameters.
- 1 July 2020
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 54 (4) , 444-453
Factors that Predicts the Size of Autologous Hamstring Tendon Graft for Double-Bundle ACL Reconstruction
Background To evaluate the effectiveness of demographic data and radiographic measurements for predicting the diameter and length of autologous semitendinosus (ST) and gracilis (GR) graft. Materials and Methods Fifty-four cases were included to measure the size of 3 or 4 strands of ST and GR tendons retrospectively. The hamstring length on radiograph was defined as the length from the lowest point of ischial tuberosity to intercondylar notch of the femur. The linear and logistic regression analysis was used to assess the roles of the predictor variables, as demographic and radiologic data, in the outcome variables, as diameter of tendon grafts. The cross-validation with hold-out samples and concordance correlation coefficient (CCC) were also calculated. Results The hamstring and leg length measurement and gender were associated with the diameter of 4-stranded ST tendon graft. The hamstring length measurement, age and BMI were the factors associated with the diameter of 3-stranded ST tendon graft. The hamstring length measurement was found as a common factor for predicting diameters of hamstring tendon with reliable predictability. Moreover, the equation of multivariate regression analysis for the diameter of 4-stranded ST tendon graft showed the most validated power of prediction. All of the cross-validated R-2 values were calculated as similar results of multivariate model, but CCC between the measured diameter and estimated value on the predictive equation showed moderate agreement only (CCC = 0.694). Conclusions Combining radiographic length measurements with demographic data showed reliable prediction in identifying the risk of inappropriate graft diameters.
- Open Access
- 18 July 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 227
Combined use of topical intraarticular tranexamic acid and rivaroxaban in total knee arthroplasty safely reduces blood loss, transfusion rates, and wound complications without increasing the risk of thrombosis
Blood loss and deep vein thrombosis (DVT) are important complications after total knee arthroplasty (TKA). Topical tranexamic acid (TXA) effectively reduces wound bleeding but may elevate the risk of DVT. In contrast, rivaroxaban potently prevents DVT but has been associated with bleeding complications. The simultaneous use of topical TXA and rivaroxaban in TKA has not been much investigated. A retrospective cohort study was conducted with two consecutive groups of patients who underwent TKA. Intraoperatively, one group (RVTX group) received topical, intraarticular TXA, while the other (RV group) did not. Both groups were administered rivaroxaban postoperatively for 14 days and underwent Doppler ultrasound for DVT screening. After propensity score matching, both groups consisted of 52 patients (104 patients in total) and were compared regarding total drain output, nadir haemoglobin (Hb), maximum Hb decrease, calculated total blood loss, transfusion rate, and incidence of DVT and wound complications. Both groups showed no significant differences in the propensity-matched variables of age, sex, body mass index, American Society of Anesthesiologists physical status score, and preoperative Hb. The RVTX group showed a significantly higher nadir Hb (p < 0.001), lower drain output (p < 0.001), Hb decrease (p = 0.015), total blood loss (p < 0.001), and rate of transfusion (p < 0.001) and fewer wound complications (p = 0.027). However, the incidence of DVT (p = 1.000) did not differ significantly between the two groups, and all cases were asymptomatic. The combined use of intraarticular topical TXA with rivaroxaban in patients undergoing TKA is a safe and effective method to reduce blood loss, the need for transfusion, and wound complications without elevating the risk of DVT.
- 18 July 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 227
Open AccessCombined use of topical intraarticular tranexamic acid and rivaroxaban in total knee arthroplasty safely reduces blood loss, transfusion rates, and wound complications without increasing the risk of thrombosis
Blood loss and deep vein thrombosis (DVT) are important complications after total knee arthroplasty (TKA). Topical tranexamic acid (TXA) effectively reduces wound bleeding but may elevate the risk of DVT. In contrast, rivaroxaban potently prevents DVT but has been associated with bleeding complications. The simultaneous use of topical TXA and rivaroxaban in TKA has not been much investigated. A retrospective cohort study was conducted with two consecutive groups of patients who underwent TKA. Intraoperatively, one group (RVTX group) received topical, intraarticular TXA, while the other (RV group) did not. Both groups were administered rivaroxaban postoperatively for 14 days and underwent Doppler ultrasound for DVT screening. After propensity score matching, both groups consisted of 52 patients (104 patients in total) and were compared regarding total drain output, nadir haemoglobin (Hb), maximum Hb decrease, calculated total blood loss, transfusion rate, and incidence of DVT and wound complications. Both groups showed no significant differences in the propensity-matched variables of age, sex, body mass index, American Society of Anesthesiologists physical status score, and preoperative Hb. The RVTX group showed a significantly higher nadir Hb (p < 0.001), lower drain output (p < 0.001), Hb decrease (p = 0.015), total blood loss (p < 0.001), and rate of transfusion (p < 0.001) and fewer wound complications (p = 0.027). However, the incidence of DVT (p = 1.000) did not differ significantly between the two groups, and all cases were asymptomatic. The combined use of intraarticular topical TXA with rivaroxaban in patients undergoing TKA is a safe and effective method to reduce blood loss, the need for transfusion, and wound complications without elevating the risk of DVT.
- 1 February 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (8) , 2710-2717
Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty
Purpose Limited information is available regarding the effects of cementing extent on implant stability in patients who have undergone revision total knee arthroplasty (TKA). As such, the goals of this study were: (1) to determine the correlation between the extent of vertical cementing and implant loosening; (2) to determine whether the extent of cementing is a potential predictive factor for radiolucency; and (3) to evaluate the minimal amount of cement needed for a stable implant during revision TKA using a hybrid technique. Methods One hundred nine stemmed/revision TKAs with a mean follow-up period of 5 years were retrospectively analysed. In each case, a single varus–valgus constrained implant was used and fixed with a hybrid technique. Implant stability was evaluated according to the modified Knee Society radiographic scoring system. The extent of vertical cementing was defined as the longitudinal length from the implant base to the end of the radiopaque line around the stem on radiograph. Its correlation with implant stability was analysed, and the minimal value for a stable implant was evaluated with a receiver operating characteristic (ROC) analysis. Results The mean extent of vertical cementing was longer in stable implants (femur: p = 0.001, tibia: p = 0.004) and significantly correlated with implant stability (femur: p < 0.001, tibia: p = 0.001). A logistic regression analysis revealed that the risk of loosening was 8.7–16.1 times higher when the extent of cementing was 60 mm for the femur and 50 mm for the tibia was durable at a mean follow-up period of 5 years. Vertical cementing 10–20 mm above the stem–implant junction is recommended when performing revision TKA using this technique. Level of evidence IV.
- 1 February 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (8) , 2710-2717
Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty
Purpose Limited information is available regarding the effects of cementing extent on implant stability in patients who have undergone revision total knee arthroplasty (TKA). As such, the goals of this study were: (1) to determine the correlation between the extent of vertical cementing and implant loosening; (2) to determine whether the extent of cementing is a potential predictive factor for radiolucency; and (3) to evaluate the minimal amount of cement needed for a stable implant during revision TKA using a hybrid technique. Methods One hundred nine stemmed/revision TKAs with a mean follow-up period of 5 years were retrospectively analysed. In each case, a single varus–valgus constrained implant was used and fixed with a hybrid technique. Implant stability was evaluated according to the modified Knee Society radiographic scoring system. The extent of vertical cementing was defined as the longitudinal length from the implant base to the end of the radiopaque line around the stem on radiograph. Its correlation with implant stability was analysed, and the minimal value for a stable implant was evaluated with a receiver operating characteristic (ROC) analysis. Results The mean extent of vertical cementing was longer in stable implants (femur: p = 0.001, tibia: p = 0.004) and significantly correlated with implant stability (femur: p < 0.001, tibia: p = 0.001). A logistic regression analysis revealed that the risk of loosening was 8.7–16.1 times higher when the extent of cementing was 60 mm for the femur and 50 mm for the tibia was durable at a mean follow-up period of 5 years. Vertical cementing 10–20 mm above the stem–implant junction is recommended when performing revision TKA using this technique. Level of evidence IV.