AOArne Ohrndorf

Arne Ohrndorf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arne Ohrndorf has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization of the Isothermal and Thermomechanical Fatigue Behavior of a Duplex Steel Considering the Alloy Microstructure

    by Steven Schellert, Julian Müller, Arne Ohrndorf, Bronslava Gorr, Benjamin Butz, Hans-Jürgen Christ

    Isothermal and thermomechanical fatigue behavior of duplex stainless steel (DSS) X2CrNiMoN22-5-3 was investigated. The aim of this work was to understand the fatigue behavior by correlation of the isothermal and thermomechanical fatigue behavior with microstructural observations. Fatigue tests at plastic-strain-amplitude of 0.2% were carried out at 20, 300 and 600 °C, while in-phase (IP) and out-of-phase (OP) thermomechanical fatigue (TMF) experiments were performed between 300 and 600 °C. During the 20 °C fatigue test, a continuous softening was observed. Transmission electron microscopy examinations reveal pronounced planar slip behavior in austenite. At 300 °C, deformation concentrates in the ferrite, where strong interactions between CrxN and dislocations were observed that explain the pronounced cyclic hardening. DSS studied exhibits softening throughout the whole isothermal fatigue test at 600 °C. In ferrite, during the 600 °C fatigue test, the G phase, γ′ austenite precipitated, and an unordered dislocation arrangement was observed. The stress responses of the TMF tests can be correlated to those of the isothermal fatigue tests. In IP mode, a positive mean stress resulted in premature failure. No γ′ austenite but the formation of subgrains in the ferrite phase was observed after TMF tests. The plastic deformation of the austenite at high temperatures results in an unordered dislocation arrangement.


  • Open Access

    Biomechanics of common fixation devices for first tarsometatarsal joint fusion—a comparative study with synthetic bones

    by Rene Burchard, Robin Massa, Christian Soost, Wolfgang Richter, Gerhard Dietrich, Arne Ohrndorf, Hans-Jürgen Christ, Claus-Peter Fritzen, Jan Adriaan Graw, Jan Schmitt

    Hallux valgus disease is a common deformity of the forefoot. There are currently more than 100 surgical approaches for operative treatment. Because hypermobility of the first tarsometatarsal joint is considered to be causal for hallux valgus disease, fusion of the tarsometatarsal joint is an upcoming surgical procedure. Despite the development of new and increasingly stable fixation devices like different locking plates, malunion rates have been reported in 5 to 15% of cases. Biomechanical comparison of three commonly used fixation devices (a dorsal locking plate, a plantar locking plate, and an intramedullary fixation device) was performed by weight-bearing simulation tests on synthetic bones. Initial compression force and stiffness during simulation of postoperative weight-bearing were analysed. Fixation of the first tarsometatarsal joint with the plantar plate combination demonstrated a higher stiffness compared to fixation with the intramedullary implant or the medial locking plate. The intramedullary device provided the highest initial compression force. Failure was detected in the following ranking: (1) the angle-stable intramedullary fixation device, (2) the medial located plate, and (3) the plantar locking plate. The intramedullary device demonstrated the highest initial compression force of the three tested implants. The plantar locking plate showed the best overall stability during weight-bearing simulation. Further clinical research is necessary to analyse if the intramedullary fixation device needs a longer period of non-weight-bearing to reach a better non-union rate compared to the plantar locking plate.


  • Intramedullary nailing in opening wedge high tibial osteotomy—in vitro test for validation of a method of fixation

    by Rene Burchard, Denise Katerla, Marina Hammer, Anke Pahlkötter, Christian Soost, Gerhard Dietrich, Arne Ohrndorf, Wolfgang Richter, Markus Lengsfeld, Hans-Jürgen Christ, et al.

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant.