Nathaniel Taylor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nathaniel Taylor has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- James Nonnemaker
RTI International
8 shared publications - Lauren McCarl Dutra
Policy and Regulatory Science Program, RTI International, Research Triangle Park, North Carolina, USA
7 shared publications - Annice Kim
Center for Health Policy Science and Tobacco Research RTI International Research Triangle Park, NC United States
6 shared publications - Brian Bradfield
Social Sciences, Statistics, and Environmental Sciences, RTI International, 3040 East Cornwallis Ave, Research Triangle Park, NC, 27709, USA
4 shared publications - Jamie Guillory
RTI International, Research Triangle Park, North Carolina
4 shared publications - Jialu Cheng
KTH Royal Institute of Technology, Stockholm, Sweden
4 shared publications
Latest Publications
- Open Access
- 14 March 2025
- Published by Elsevier in American Journal of Preventive Medicine
- Vol. 70 (5) , 107614
The Impact of “The Real Cost” on E-cigarette Initiation Among U.S. Youth
- 14 March 2025
- Published by Elsevier in American Journal of Preventive Medicine
- Vol. 70 (5) , 107614
Open AccessThe Impact of “The Real Cost” on E-cigarette Initiation Among U.S. Youth
- Open Access
- 25 December 2024
- Published by MDPI AG in Electronics
- Vol. 14 (1) , 31
Electromagnetic Interference from Solar Photovoltaic Systems: A Review
Rapid expansion of solar photovoltaic (PV) installations worldwide has increased the importance of electromagnetic compatibility (EMC) of PV components and systems. This has been highlighted by interference reported from PV installations (PVI) in the Netherlands, the United States, Sweden, etc. Significant research and development efforts are seen in the domain of enhancing efficiency and economic viability of PVI, whereas the EMC aspects have received less attention and are mainly focused on the PV system acting as a victim of lightning and a victim of changing grid impedance. This article presents a review of the important EMC aspects of PVI as a disturbance source. It has the following main parts: (a) reported cases of emissions and interference from PV installations; (b) modeling and analysis of PV subcomponents from an EMC perspective; and (c) the main standards related to the topic. Mitigation techniques for improving EMC aspects of PVI are also described, along with suggested directions for future research. The compilation brings together wide-ranging sources, both for EMC engineers who want to understand the EMC context of PV systems and for PV system designers seeking to improve EMC performance.
- 25 December 2024
- Published by MDPI AG in Electronics
- Vol. 14 (1) , 31
Open AccessElectromagnetic Interference from Solar Photovoltaic Systems: A Review
Rapid expansion of solar photovoltaic (PV) installations worldwide has increased the importance of electromagnetic compatibility (EMC) of PV components and systems. This has been highlighted by interference reported from PV installations (PVI) in the Netherlands, the United States, Sweden, etc. Significant research and development efforts are seen in the domain of enhancing efficiency and economic viability of PVI, whereas the EMC aspects have received less attention and are mainly focused on the PV system acting as a victim of lightning and a victim of changing grid impedance. This article presents a review of the important EMC aspects of PVI as a disturbance source. It has the following main parts: (a) reported cases of emissions and interference from PV installations; (b) modeling and analysis of PV subcomponents from an EMC perspective; and (c) the main standards related to the topic. Mitigation techniques for improving EMC aspects of PVI are also described, along with suggested directions for future research. The compilation brings together wide-ranging sources, both for EMC engineers who want to understand the EMC context of PV systems and for PV system designers seeking to improve EMC performance.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Letters on Electromagnetic Compatibility Practice and Applications
- Vol. 6 (1) , 16-21
Investigations Into Conducted Emissions of a 10-kW Photovoltaic Plant
Considering inverter as the source of electromagnetic emission signals in a photovoltaic (PV) plant, a comprehensive set of measurements of conducted emissions at the input and output of the inverter in a 10 kW PV plant are presented. These are particularly relevant on the backdrop of (a) ban of products in the EU market due to non-compliance and (b) the increased switching frequency in the inverters ( 100s of kHz) in near future. Specifically, the common mode (CM) and differential mode (DM) currents and voltages are measured, and their frequency domain behavior is studied. It is suggested that conducted emissions from PV can be classified into three zones: viz., extremely low frequency (ELF) zone, power frequency zone, and switching frequency zone. Important observations from this exercise are measurement of harmonic contents of current with total rated current distortion (TRD), imbalance in the output voltage and low frequency ripples in the DC voltage. Frequency domain behavior of the CM quantities is studied which throws light on important points like relation between input and output CM quantities, relation between CM voltage and CM current.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Letters on Electromagnetic Compatibility Practice and Applications
- Vol. 6 (1) , 16-21
Investigations Into Conducted Emissions of a 10-kW Photovoltaic Plant
Considering inverter as the source of electromagnetic emission signals in a photovoltaic (PV) plant, a comprehensive set of measurements of conducted emissions at the input and output of the inverter in a 10 kW PV plant are presented. These are particularly relevant on the backdrop of (a) ban of products in the EU market due to non-compliance and (b) the increased switching frequency in the inverters ( 100s of kHz) in near future. Specifically, the common mode (CM) and differential mode (DM) currents and voltages are measured, and their frequency domain behavior is studied. It is suggested that conducted emissions from PV can be classified into three zones: viz., extremely low frequency (ELF) zone, power frequency zone, and switching frequency zone. Important observations from this exercise are measurement of harmonic contents of current with total rated current distortion (TRD), imbalance in the output voltage and low frequency ripples in the DC voltage. Frequency domain behavior of the CM quantities is studied which throws light on important points like relation between input and output CM quantities, relation between CM voltage and CM current.
- Open Access
A Study of Frequency Domain Reflectometry Technique for High-Voltage Rotating Machine Winding Condition Assessment
Detecting and locating local degradations at an incipient stage is very important for mission-critical high-voltage rotating machines. One particular challenge in the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on the scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially created defects. These defects include turn-to-turn short, surface creepage, loose coils, insufficient end-winding spacing, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that FDR can identify and locate structural and insulation degradation in both shielded and unshielded objects with good sensitivity. This makes FDR a complementary technique for machine fault diagnosis and aging assessment.
Open AccessA Study of Frequency Domain Reflectometry Technique for High-Voltage Rotating Machine Winding Condition Assessment
Detecting and locating local degradations at an incipient stage is very important for mission-critical high-voltage rotating machines. One particular challenge in the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on the scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially created defects. These defects include turn-to-turn short, surface creepage, loose coils, insufficient end-winding spacing, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that FDR can identify and locate structural and insulation degradation in both shielded and unshielded objects with good sensitivity. This makes FDR a complementary technique for machine fault diagnosis and aging assessment.
- Open Access
- 9 August 2023
- Published by MDPI AG in Preprints.org
The Study of Frequency Domain Reflectometry Technique for High Voltage Rotating Machine Winding Condition Assessment
Detecting, especially locating local degradations at an incipient stage, is very important for mission-critical high voltage rotating machines. One particular challenge of the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially made defects. These defects include turn-to-turn short, surface creepage, loose coils, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that the FDR can identify and locate both structure and insulation degradations of both shielded and unshielded objects with good sensitivity. This makes the FDR a comprehensive tool for fault diagnosis and aging assessment.
- 9 August 2023
- Published by MDPI AG in Preprints.org
Open AccessThe Study of Frequency Domain Reflectometry Technique for High Voltage Rotating Machine Winding Condition Assessment
Detecting, especially locating local degradations at an incipient stage, is very important for mission-critical high voltage rotating machines. One particular challenge of the existing testing techniques is that the characteristic of a local incipient defect is not prominent due to various factors such as averaging with the healthy remainder, attenuation in signal propagation, interference, and varied operating conditions. This paper proposes and investigates the frequency domain reflectometry (FDR) technique based on scattering parameter measurement. The FDR result presents the object length, wave impedance, and reflections due to impedance discontinuity along the measured windings. Experiments were performed on two commercial coils with artificially made defects. These defects include turn-to-turn short, surface creepage, loose coils, and local overheating, which are commonly seen in practice. Two practical water pumps in the field were also selected for investigation. The study outcome shows that the FDR can identify and locate both structure and insulation degradations of both shielded and unshielded objects with good sensitivity. This makes the FDR a comprehensive tool for fault diagnosis and aging assessment.
- Open Access
- 24 March 2023
- Published by MDPI AG in Electricity
- Vol. 4 (2) , 96-113
Incremental Phase-Current Based Fault Passage Indication for Earth Faults in Resonant Earthed Networks
We propose a method for the fault passage indication of earth faults in resonant-earthed networks, based on phase current measurements alone. This is particularly relevant for electricity distribution systems at medium-voltage levels. The method is based on the relative magnitudes of the phasor changes in the phase currents due to the fault. It is tested for various network types and operation configurations by simulating the network in pscad and using the simulated currents as the input for an implementation of the method in matlab. In over-compensated networks, the method shows reliable detection of the fault passage, with good selectivity and sensitivity for both homogeneous and mixed (cable and overhead line) feeders. However, for the less common under-compensated systems, it has limitations that are described further in this study. The method has good potential for being cost effective since it requires only current measurements, from a single location, at a moderate sampling rate.
- 24 March 2023
- Published by MDPI AG in Electricity
- Vol. 4 (2) , 96-113
Open AccessIncremental Phase-Current Based Fault Passage Indication for Earth Faults in Resonant Earthed Networks
We propose a method for the fault passage indication of earth faults in resonant-earthed networks, based on phase current measurements alone. This is particularly relevant for electricity distribution systems at medium-voltage levels. The method is based on the relative magnitudes of the phasor changes in the phase currents due to the fault. It is tested for various network types and operation configurations by simulating the network in pscad and using the simulated currents as the input for an implementation of the method in matlab. In over-compensated networks, the method shows reliable detection of the fault passage, with good selectivity and sensitivity for both homogeneous and mixed (cable and overhead line) feeders. However, for the less common under-compensated systems, it has limitations that are described further in this study. The method has good potential for being cost effective since it requires only current measurements, from a single location, at a moderate sampling rate.
- Open Access
- 18 February 2022
- Published by Elsevier in Addictive Behaviors
- Vol. 130, 107286
Predictive validity of the original and expanded susceptibility scales for smokeless tobacco
- 18 February 2022
- Published by Elsevier in Addictive Behaviors
- Vol. 130, 107286
Open AccessPredictive validity of the original and expanded susceptibility scales for smokeless tobacco
- Open Access
- 11 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 18192-18200
Impact of Surfactants on the Electrical and Rheological Aspects of Silica Based Synthetic Ester Nanofluids
This study reports experimental investigations of the effects of different surfactants (CTAB, Oleic acid and Span 80) on silica based synthetic ester nanofluids. The positive and negative potential observed for the ionic (CTAB) and non-ionic surfactant (Span 80) from zeta potential analysis indicates an improved stability. The optimization of nanofillers and surfactants is performed considering the corona inception voltage measured using ultra high frequency (UHF) technique and fluorescent fiber. Rheological analysis shows no significant variation of properties with shear rate, implying Newtonian behavior even with the addition of surfactant. In addition, the permittivity of the nanofluid is not much affected by adding surfactant but a marginal variation is noticed in the loss tangent with the effect of temperature. The fluorescence spectroscopy shows no change in the emission wavelength with the addition of silica nanofiller and surfactants. Flow electrification studies indicate an increase in the streaming current with the rotation speed and temperature, with a higher current magnitude observed in the case of nanofluids.
- 11 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 18192-18200
Open AccessImpact of Surfactants on the Electrical and Rheological Aspects of Silica Based Synthetic Ester Nanofluids
This study reports experimental investigations of the effects of different surfactants (CTAB, Oleic acid and Span 80) on silica based synthetic ester nanofluids. The positive and negative potential observed for the ionic (CTAB) and non-ionic surfactant (Span 80) from zeta potential analysis indicates an improved stability. The optimization of nanofillers and surfactants is performed considering the corona inception voltage measured using ultra high frequency (UHF) technique and fluorescent fiber. Rheological analysis shows no significant variation of properties with shear rate, implying Newtonian behavior even with the addition of surfactant. In addition, the permittivity of the nanofluid is not much affected by adding surfactant but a marginal variation is noticed in the loss tangent with the effect of temperature. The fluorescence spectroscopy shows no change in the emission wavelength with the addition of silica nanofiller and surfactants. Flow electrification studies indicate an increase in the streaming current with the rotation speed and temperature, with a higher current magnitude observed in the case of nanofluids.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (1) , 240-246
Nonlinear Dielectric Properties of the Stator and Transformer Insulation Systems
Composite insulation systems usually exhibit nonlinear phenomena, such as voltage-dependent dielectric response and high-order current harmonics. In this article, a high-voltage system capable of performing both dielectric frequency response (DFR) and polarization/depolarization current (PDC) measurements up to 20 kV is devised. The nonlinear properties of the motor stator and power transformer insulation systems are studied. Experimental results show that the voltage-dependent effect becomes significant as the voltage magnitude approaches the nominal and frequency decreases. The third current harmonic component is found to be dominant over the other components and has a strong correlation with the decrease in the dissipation factor. By taking both the fundamental and third-harmonic components into account, more consistent voltage-dependent characteristics are revealed. These features are important indications of insulation defects that are often neglected in field diagnostic testings. The investigation of the nonlinear properties helps to enhance the condition diagnosis reliability.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (1) , 240-246
Nonlinear Dielectric Properties of the Stator and Transformer Insulation Systems
Composite insulation systems usually exhibit nonlinear phenomena, such as voltage-dependent dielectric response and high-order current harmonics. In this article, a high-voltage system capable of performing both dielectric frequency response (DFR) and polarization/depolarization current (PDC) measurements up to 20 kV is devised. The nonlinear properties of the motor stator and power transformer insulation systems are studied. Experimental results show that the voltage-dependent effect becomes significant as the voltage magnitude approaches the nominal and frequency decreases. The third current harmonic component is found to be dominant over the other components and has a strong correlation with the decrease in the dissipation factor. By taking both the fundamental and third-harmonic components into account, more consistent voltage-dependent characteristics are revealed. These features are important indications of insulation defects that are often neglected in field diagnostic testings. The investigation of the nonlinear properties helps to enhance the condition diagnosis reliability.