Taeyong Sim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Taeyong Sim has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Joung Hwan Mun
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
4 shared publications - Ahnryul Choi
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, 300 Chunchun, Jangan, Suwon, Gyeonggi 440-746, Republic of Korea
2 shared publications - Hyun Mu Heo
Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Republic of Korea, 2066 Seoburo, Jangangu, Suwon, Gyeonggi, 16419, Republic of Korea
2 shared publications - Hyunggun Kim
Department of Biomechatronic Engineering, Sungkyunkwan University, Republic of Korea
2 shared publications - Benjamin Cates
LSMtron Ltd., Dongan-gu, Anyang-si 14118, Gyeonggi-do, Korea
1 shared publication - Bori Kim
Department of Research and Development, Biomaterial Team, Medical Device Development Center, KBIO HEALTH, 123 Osongsaengmyung-ro, Osong-eub, Heungdeok-gu, Cheongju, Chungbuk 28160, Korea
1 shared publication
Latest Publications
- Open Access
- 22 June 2018
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 15 (1) , 54
Analysis of sensory system aspects of postural stability during quiet standing in adolescent idiopathic scoliosis patients
The aim of this study was to quantitatively analyze quite standing postural stability of adolescent idiopathic scoliosis (AIS) patients in respect to three sensory systems (visual, vestibular, and somatosensory). In this study, we analyzed the anterior-posterior center of pressure (CoP) signal using discrete wavelet transform (DWT) between AIS patients (n = 32) and normal controls (n = 25) during quiet standing. The energy rate (∆E EYE %) of the CoP signal was significantly higher in the AIS group than that in the control group at levels corresponding to vestibular and somatosensory systems (p < 0.01). This implies that AIS patients use strategies to compensate for possible head position changes and spinal asymmetry caused by morphological deformations of the spine through vestibular and somatosensory systems. This could be interpreted that such compensation could help them maintain postural stability during quiet standing. The interpretation of CoP signal during quiet standing in AIS patients will improve our understanding of changes in physical exercise ability due to morphological deformity of the spine. This result is useful for evaluating postural stability before and after treatments (spinal fusion, bracing, rehabilitation, and so on).
- 22 June 2018
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 15 (1) , 54
Open AccessAnalysis of sensory system aspects of postural stability during quiet standing in adolescent idiopathic scoliosis patients
The aim of this study was to quantitatively analyze quite standing postural stability of adolescent idiopathic scoliosis (AIS) patients in respect to three sensory systems (visual, vestibular, and somatosensory). In this study, we analyzed the anterior-posterior center of pressure (CoP) signal using discrete wavelet transform (DWT) between AIS patients (n = 32) and normal controls (n = 25) during quiet standing. The energy rate (∆E EYE %) of the CoP signal was significantly higher in the AIS group than that in the control group at levels corresponding to vestibular and somatosensory systems (p < 0.01). This implies that AIS patients use strategies to compensate for possible head position changes and spinal asymmetry caused by morphological deformations of the spine through vestibular and somatosensory systems. This could be interpreted that such compensation could help them maintain postural stability during quiet standing. The interpretation of CoP signal during quiet standing in AIS patients will improve our understanding of changes in physical exercise ability due to morphological deformity of the spine. This result is useful for evaluating postural stability before and after treatments (spinal fusion, bracing, rehabilitation, and so on).
- Open Access
A Novel Detection Model and Its Optimal Features to Classify Falls from Low- and High-Acceleration Activities of Daily Life Using an Insole Sensor System
In order to overcome the current limitations in current threshold-based and machine learning-based fall detectors, an insole system and novel fall classification model were created. Because high-acceleration activities have a high risk for falls, and because of the potential damage that is associated with falls during high-acceleration activities, four low-acceleration activities, four high-acceleration activities, and eight types of high-acceleration falls were performed by twenty young male subjects. Encompassing a total of 800 falls and 320 min of activities of daily life (ADLs), the created Support Vector Machine model’s Leave-One-Out cross-validation provides a fall detection sensitivity (0.996), specificity (1.000), and accuracy (0.999). These classification results are similar or superior to other fall detection models in the literature, while also including high-acceleration ADLs to challenge the classification model, and simultaneously reducing the burden that is associated with wearable sensors and increasing user comfort by inserting the insole system into the shoe.
Open AccessA Novel Detection Model and Its Optimal Features to Classify Falls from Low- and High-Acceleration Activities of Daily Life Using an Insole Sensor System
In order to overcome the current limitations in current threshold-based and machine learning-based fall detectors, an insole system and novel fall classification model were created. Because high-acceleration activities have a high risk for falls, and because of the potential damage that is associated with falls during high-acceleration activities, four low-acceleration activities, four high-acceleration activities, and eight types of high-acceleration falls were performed by twenty young male subjects. Encompassing a total of 800 falls and 320 min of activities of daily life (ADLs), the created Support Vector Machine model’s Leave-One-Out cross-validation provides a fall detection sensitivity (0.996), specificity (1.000), and accuracy (0.999). These classification results are similar or superior to other fall detection models in the literature, while also including high-acceleration ADLs to challenge the classification model, and simultaneously reducing the burden that is associated with wearable sensors and increasing user comfort by inserting the insole system into the shoe.
- 1 September 2015
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 137 (9) , 091001
Predicting Complete Ground Reaction Forces and Moments During Gait With Insole Plantar Pressure Information Using a Wavelet Neural Network
In general, three-dimensional ground reaction forces (GRFs) and ground reaction moments (GRMs) that occur during human gait are measured using a force plate, which are expensive and have spatial limitations. Therefore, we proposed a prediction model for GRFs and GRMs, which only uses plantar pressure information measured from insole pressure sensors with a wavelet neural network (WNN) and principal component analysis-mutual information (PCA-MI). For this, the prediction model estimated GRFs and GRMs with three different gait speeds (slow, normal, and fast groups) and healthy/pathological gait patterns (healthy and adolescent idiopathic scoliosis (AIS) groups). Model performance was validated using correlation coefficients (r) and the normalized root mean square error (NRMSE%) and was compared to the prediction accuracy of the previous methods using the same dataset. As a result, the performance of the GRF and GRM prediction model proposed in this study (slow group: r = 0.840–0.989 and NRMSE% = 10.693–15.894%; normal group: r = 0.847–0.988 and NRMSE% = 10.920–19.216%; fast group: r = 0.823–0.953 and NRMSE% = 12.009–20.182%; healthy group: r = 0.836–0.976 and NRMSE% = 12.920–18.088%; and AIS group: r = 0.917–0.993 and NRMSE% = 7.914–15.671%) was better than that of the prediction models suggested in previous studies for every group and component (p < 0.05 or 0.01). The results indicated that the proposed model has improved performance compared to previous prediction models.
- 1 September 2015
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 137 (9) , 091001
Predicting Complete Ground Reaction Forces and Moments During Gait With Insole Plantar Pressure Information Using a Wavelet Neural Network
In general, three-dimensional ground reaction forces (GRFs) and ground reaction moments (GRMs) that occur during human gait are measured using a force plate, which are expensive and have spatial limitations. Therefore, we proposed a prediction model for GRFs and GRMs, which only uses plantar pressure information measured from insole pressure sensors with a wavelet neural network (WNN) and principal component analysis-mutual information (PCA-MI). For this, the prediction model estimated GRFs and GRMs with three different gait speeds (slow, normal, and fast groups) and healthy/pathological gait patterns (healthy and adolescent idiopathic scoliosis (AIS) groups). Model performance was validated using correlation coefficients (r) and the normalized root mean square error (NRMSE%) and was compared to the prediction accuracy of the previous methods using the same dataset. As a result, the performance of the GRF and GRM prediction model proposed in this study (slow group: r = 0.840–0.989 and NRMSE% = 10.693–15.894%; normal group: r = 0.847–0.988 and NRMSE% = 10.920–19.216%; fast group: r = 0.823–0.953 and NRMSE% = 12.009–20.182%; healthy group: r = 0.836–0.976 and NRMSE% = 12.920–18.088%; and AIS group: r = 0.917–0.993 and NRMSE% = 7.914–15.671%) was better than that of the prediction models suggested in previous studies for every group and component (p < 0.05 or 0.01). The results indicated that the proposed model has improved performance compared to previous prediction models.