Ajymurat Orozaliev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ajymurat Orozaliev has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yong-Ak Song
New York University Abu Dhabi
2 shared publications - Abdel F. Isakovic
Colgate University
1 shared publication - Chakra P. Joshi
Physics Department, Khalifa University, Abu Dhabi, P.O. Box 127788, United Arab Emirates
1 shared publication - Jaime Viegas
Department of Electrical Engineering, Khalifa University, Abu Dhabi, UAE
1 shared publication - Jeremy Choon Meng Teo
New York University Abu Dhabi
1 shared publication Jongmin Kim
Division of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE
1 shared publication
Latest Publications
- Open Access
Electrodeformation of White Blood Cells Enriched with Gold Nanoparticles
The elasticity of white blood cells (WBCs) provides valuable insight into the condition of the cells themselves, the presence of some diseases, as well as immune system activity. In this work, we describe a novel process of refined control of WBCs’ elasticity through a combined use of gold nanoparticles (AuNPs) and the microelectrode array device. The capture and controlled deformation of gold nanoparticles enriched white blood cells in vitro are demonstrated and quantified. Gold nanoparticles enhance the effect of electrically induced deformation and make the DEP-related processes more controllable.
Open AccessElectrodeformation of White Blood Cells Enriched with Gold Nanoparticles
The elasticity of white blood cells (WBCs) provides valuable insight into the condition of the cells themselves, the presence of some diseases, as well as immune system activity. In this work, we describe a novel process of refined control of WBCs’ elasticity through a combined use of gold nanoparticles (AuNPs) and the microelectrode array device. The capture and controlled deformation of gold nanoparticles enriched white blood cells in vitro are demonstrated and quantified. Gold nanoparticles enhance the effect of electrically induced deformation and make the DEP-related processes more controllable.
- Open Access
- 21 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (4) , 1-9
Label-Free Detection of Morpholino-DNA Hybridization Using a Silicon Photonics Suspended Slab Micro-Ring Resonator
In this study, deoxyribonucleic acid (DNA) hybridization was demonstrated using a suspended silicon photonics micro-ring resonator with a 90 nm-thick slab and morpholino as the capture probe. Complementary DNA of various concentrations were tested achieving a surface sensitivity of 2.12 nm/nM, a detection limit of 250 pM, and an intrinsic detection limit of 36.9 pM. A bulk sensitivity of 98 nm/RIU and an intrinsic detection limit of $1.03\times 10^{-3}$ RIU was also measured upon exposure to isopropanol/deionized water solutions. With these characteristics, the suspended 90 nm slab ring sensor proved as a promising candidate for lab-on-a-chip bio-sensing applications.
- 21 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (4) , 1-9
Open AccessLabel-Free Detection of Morpholino-DNA Hybridization Using a Silicon Photonics Suspended Slab Micro-Ring Resonator
In this study, deoxyribonucleic acid (DNA) hybridization was demonstrated using a suspended silicon photonics micro-ring resonator with a 90 nm-thick slab and morpholino as the capture probe. Complementary DNA of various concentrations were tested achieving a surface sensitivity of 2.12 nm/nM, a detection limit of 250 pM, and an intrinsic detection limit of 36.9 pM. A bulk sensitivity of 98 nm/RIU and an intrinsic detection limit of $1.03\times 10^{-3}$ RIU was also measured upon exposure to isopropanol/deionized water solutions. With these characteristics, the suspended 90 nm slab ring sensor proved as a promising candidate for lab-on-a-chip bio-sensing applications.
- Open Access
- 19 June 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (6) , 306
Rapid Detection and Trapping of Extracellular Vesicles by Electrokinetic Concentration for Liquid Biopsy on Chip
Exosomes have gained immense importance since their proteomic and genetic contents could potentially be used for disease diagnostics, monitoring of cancer progression, metastasis, and drug efficacy. However, establishing the clinical utility of exosomes has been restricted due to small sizes and high sample loss from extensive sample preparation. Sample loss is particularly critical for body fluids limited in volume and difficult to access, e.g., cerebrospinal fluid. We present a microfluidic technique that locally enhances the concentration of extracellular vesicles extracted from MDA-MB-231 human breast cancer cell lines by using an ion concentration polarization (ICP)-based electrokinetic concentrator. Our design incorporates a trapping mechanism near the conductive polymer membrane; therefore, we can preconcentrate and capture extracellular vesicles simultaneously. Compared with standard fluorescence detection, our method increased the limit of detection (LOD) of extracellular vesicles by two orders of magnitude in 30 min. Our concentrator increased the extracellular vesicle concentration for 5.0 × 107 particles/1 mL (LOD), 5.0 × 108 particles/1 mL, and 5.0 × 109 particles/1 mL by ~100-fold each within 30 min using 45 V. This study demonstrates an alternative platform to simultaneously preconcentrate and capture extracellular vesicles that can be incorporated as part of a liquid biopsy-on-a-chip system for the detection of exosomal biomarkers and analysis of their contents for early cancer diagnosis.
- 19 June 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (6) , 306
Open AccessRapid Detection and Trapping of Extracellular Vesicles by Electrokinetic Concentration for Liquid Biopsy on Chip
Exosomes have gained immense importance since their proteomic and genetic contents could potentially be used for disease diagnostics, monitoring of cancer progression, metastasis, and drug efficacy. However, establishing the clinical utility of exosomes has been restricted due to small sizes and high sample loss from extensive sample preparation. Sample loss is particularly critical for body fluids limited in volume and difficult to access, e.g., cerebrospinal fluid. We present a microfluidic technique that locally enhances the concentration of extracellular vesicles extracted from MDA-MB-231 human breast cancer cell lines by using an ion concentration polarization (ICP)-based electrokinetic concentrator. Our design incorporates a trapping mechanism near the conductive polymer membrane; therefore, we can preconcentrate and capture extracellular vesicles simultaneously. Compared with standard fluorescence detection, our method increased the limit of detection (LOD) of extracellular vesicles by two orders of magnitude in 30 min. Our concentrator increased the extracellular vesicle concentration for 5.0 × 107 particles/1 mL (LOD), 5.0 × 108 particles/1 mL, and 5.0 × 109 particles/1 mL by ~100-fold each within 30 min using 45 V. This study demonstrates an alternative platform to simultaneously preconcentrate and capture extracellular vesicles that can be incorporated as part of a liquid biopsy-on-a-chip system for the detection of exosomal biomarkers and analysis of their contents for early cancer diagnosis.